CEILING INSTALLATION
Heater platform and clearances
The heater must be mounted on a platform to enable access for
servicing and maintenance.
Minimum clearances must be maintained around the heater as
shown.
A 600mm wide walkway must be provided from the ceiling
access point to the appliance.
Permanent artificial lighting must be provided at the appliance
with the switch adjacent to the access opening.
Check that the section of the roof in which the heater is to be
installed is capable of supporting the additional load of the
heater. Where possible, the heater should be mounted over a
load-bearing wall so that it is not being supported by the ceiling
joists alone.
Check that the heater does not cause deformation of any part of
the building structure.
Flue connection - TQ3, TQ4, TQM5, TQS3, TQS4
This heater must be flued using AGA approved 100 mm metal
flue pipe.
External joins - socket must face downwards. Internal joins -
socket must face upwards.
Socket joins must be adequately sealed - eg, Silastic 747 silicone
sealant.
Twin-wall metal flue must be used for any part of the flue that is
not readily accessible.
Twin-wall metal flue is recommended for flue exceeding 2m in
length.
Flue lengths:
Flue bends:
- Maximum vertical: 4.8m
- Maximum 2 x 90
o
elbows
- Maximum horizontal: 4m
- 2 x 45o bends = 1 x 90
o
elbow
- Maximum total: 6m
Permanent Platform
19 mm particle board
or equivalent
500 mm to nearest
part of roof
200 mm minimum
for servicing
Fire resistant base NOT REQUIRED
100 mm flue cowl
AGA approved
100 mm 90
o
bend
100 mm flue pipe
Single or twin skin
AGA approved
HX END
OF HEATER
ROOM FAN
END OF
HEATER
Ensure 200mm minimum clearance above heater
Service/maintenance platform - 19mm particle board or equivalent
HEATER LOCATION
AVOID QUIET AREAS:
- Above bedrooms, living room,
lounge room, dining room etc
PREFERRED LOCATIONS:
- Above laundry, bathroom,
kitchen, garage etc’
Flue
E
A
A = 385 or 510
Depends on model.
See page 9.
E = 770, 880,1160
Depends on model - see
“Heater Dimensions” page
750 Min
Gas
supply
Isolation
valve
750 Min
90
o
bend and starter collars are included in internal installation
accessories kit.
Larger starter collars (400mm) required for the X30,X32 & 35kW
units are supplied inside the heater fan inlet.
Fit flue socket
to heater
Fitting the flue
Fit flue elbow
inside socket
on heater
Fit flue pipe
inside socket
on flue elbow
SEAL CONNECTIONS: Seal flue and condensate drain connections using
silicone sealant or
PVC primer and solvent cement.
INSULATE DRAIN LINE: Fit insulation (eg, Armaflex) over full length of condensate drain line in sub-zero climates
Minimum 500mm to
nearest part of roof
100mm plastic
DWV vent cowl
100mm plastic
DWV pipe
100mm plastic
DWV M-F elbow
200mm minimum for
maintenance and servicing
access
Vent cowl, condensate drain tee assembly,
flue drain elbow and flue drain hose are
supplied in internal installation accessories kit.
Terminate condensate drain
in a suitable location
Remove & discard flue
transit plug & one drain
transit plug
Fix flue elbow in place
with screw
Condensate drain tee
assembly
Flue drain elbow
Flue drain hose
Secure condensate drain to
flexible tube using hose
clamp supplied
Flue & condensate drain connection
Condensate drain tee assembly:
The flexible tube supplied as part of the condensate drain tee assembly is intended to prevent excessive strain of the condensate drain fittings when
fitting and securing the rigid PVC drain line. It is not designed to take the place of a 90
o
bend.
Seal remaining drain transit plug located on the opposite side of the heater to
condensate drain using silicone sealant or PVC primer and solvent cement.
11
TQ3, TQ4, TQ5, TQM5, TQM6, TQS3, TQS4, TQS5, TQS6