background image

 

13 

 

 

 

 

PLEASE READ ALL INSTRUCTIONS CAREFULLY  

BEFORE OPERATING THE PRODUCT 

• 

Power – plug the power into a standard 115V power supply outlet. 

• 

Press “ON/OFF” button on control panel to start the unit. 

• 

The screen will display the current humidity setting value and press “+” or “—” to adjust desired 

humidity increments of 1%. Press and hold the button to make faster adjustments. Setting the 

humidity value below 30% will allow the unit enter into “continuous dehumidifying” mode and “CO” 

will briefly appear on the screen. 

• 

Press “ON/OFF” again to shut down the dehumidifier and do not forget to unplug the power when not 

in use

.

 

• 

 

Tips – the best humidity range for human health, furniture and other goods protection is 45% 

- 65%. We suggest you keep the humidity in this range 

 

 

Installation and Operation Guide 

Operation

 

Do not handle the plug 

with wet hands. 

Electric shock may 

occur, resulting in 

injury or death

• 

When the humidity setting is higher than 
the current room humidity, the 
compressor will not run and fan motor 
continues running. 

• 

Maintaining the humidity between 45-65% 
is suggested for best results. 

 

NOTE: NEVER attempt to start, stop and 
restart the unit without waiting at least 3 
minutes. Failure to do so may cause 
damage to the compressor and/ or cause 
unit failure. 

 

• 

The unit will automatically sense when it 
needs to enter the 

Defrost

 mode, 

especially in low-temperature 
environments. During defrosting, the 

Defrost

 Indicator will illuminate on the 

display, the compressor will turn off, and 
the fan motor will run until the cycle is 
complete. 

 
 

• 

Accumulated run time on the display 
indicates the total number of hours that 
the unit has been operated. 

 
 

NOTE: ALWAYS unplug the unit, properly 
wrap the power cord and utilize the plug 
storage receptacle before moving or 
servicing. Use only the ON/OFF button to 
turn the unit on and off. 

 

 

DO NOT block the grids when the unit is in 

use. Keep metal objects away from the 

unit. Bodily injury or property damage may 

occur. 

 

Summary of Contents for ECO Series

Page 1: ...signedforGrowingIndustry MaximumCapacityatover210PintsPerDay ProductCategory H50 H60 H70 H70B H90 H100 IMPORTANT After unpacking or accidental tip over allow dehumidifier to stand upright for 20 minutes before starting READ THIS MANUAL CAREFULLY BEFORE OPERATING ...

Page 2: ......

Page 3: ... any solid state speed control devices DO NOT touch this appliance or the plug with wet hands or while standing in water Maintain a 12 18 inch clearance space around this unit Do NOT block or cover air inlet or outletgrilles The unit must be connected to a correctly grounded powersupply DO NOT start or stop the unit by inserting or pulling out the powerplug DO NOT use an adapter plug or extensionc...

Page 4: ...d a fair bit and can easily be transported to any operating site Owing to an external condensate drain and optionally available condensate pump ECO series product is further ideally suited for longer unattended dry keeping applications the duration of which can be determined precisely by means of the integrated operating hours counter perfect for commercial applications Drain hose x1 User s Manual...

Page 5: ...3 Drain hose x1 User s Manual x1 ECO H Dehumidifier x1 Drain hose x1 User s Manual x1 ECO H Dehumidifier x1 ECO H90 H100 have water pump pre installed Items Included ECO H70B Items Included ECO H60 ...

Page 6: ... Drain hose x1 User s Manual x1 ECO H Dehumidifier x1 Drain hose x1 User s Manual x1 ECO H Dehumidifier x1 ECO H90 H100 has water pump pre installed Items Included ECO H100 Items Included ECO H70 ECO H90 ...

Page 7: ...le Product Description ECO H50 Control Panel Handle Drainage Outlet FRONT VIEW Filter Wheel s Front Feet Water tank 9 5Pints Control Panel Power cord holder Air Outlet Pedal Grille filter Front Door Water tank Front foot REAR VIEW ...

Page 8: ...Outlet Cable Holder Product Description ECO H60 Control Panel Handle Air intake Grille FRONT VIEW Filter Wheel s Front Door Direct Drainage Plug Holder NO ELECTRICITY SUPPLY Pedal REAR VIEW Water tank 15 2 Pints Front Feet ...

Page 9: ...Front Door Product Description ECO H70B Air intake Grille Control Panel Handle Side Handle s Filter FRONT VIEW Water tank 9 5 Pints Wheel s Drainage Outlet Side Air Outlet Cable Holder Side Handle s Pedal REAR VIEW ...

Page 10: ...ption ECO H70 ECO H90 Power Cord Holder FRONT VIEW Pedal Plug Holder NO Electricity REAR VIEW Control Panel Handle Air intake Grille Filter Drainage Outlet Wheel s Front Door Front Feet H70 Water tank 22 2 Pints H90 Water pump H90 ...

Page 11: ...ide Pump Inside Drainage Outlet Cable Holder Air intake Filter Product Description ECO H100 Control Panel Handle FRONT VIEW Wheel s Roto mold Housing VIEW Roto mold Housing VIEW Air Outlet Control Panel REAR VIEW ...

Page 12: ...ecrease the desired humidity level by 1 increments Touch and hold to increase decrease the setting humidity level by 5 per second The adjustable range is 30 to 90 Information Unit makes a BEEP sound when powered on The default setting for humidity is 60 and use the Humidity Up and Down buttons to adjust the humidity setting Keep pressing the Humidity Down button to 30 to activate continuous dehumi...

Page 13: ...on switch the dehumidifier ON or OFF Humidity Setting Tap to increase decrease the desired humidity level by 1 increments Touch and hold to increase decrease the setting humidity level by 5 per second The adjustable range is 30 to 90 Pump Control Press DRAIN button to allow pump automatically empty the water inside Humidity Setting Tap to increase decrease the desired humidity level by 1 increment...

Page 14: ...er in potentially dangerous locations Before operating the unit place the unit UPRIGHT for at least 1hour to allow refrigerant to stabilize If the unit was titled on its side or upside down during transportation set the unit UPRIGHT for at least 4 hours before use The dehumidifier must be positioned UPRIGHT on a level surface during operation Environment Temperature and Humidity the dehumidifier i...

Page 15: ...jury or death When the humidity setting is higher than the current room humidity the compressor will not run and fan motor continues running Maintaining the humidity between 45 65 is suggested for best results NOTE NEVER attempt to start stop and restart the unit without waiting at least 3 minutes Failure to do so may cause damage to the compressor and or cause unit failure The unit will automatic...

Page 16: ...d by the preliminary testing done by thefactory Normally the condensate water on evaporator will be collected on the dip tray and then runs into water tank through drain hose Drain hose into water tank Drain hose through the hole on the side cover NOTE the hole is on the opposite side of the cover of model ECO H60 The dehumidifier is designed to allow using direct drain hose for removing the water...

Page 17: ... Filter CLEAN the filter periodically to keep unit running efficiently It is suggested to clean the filter monthly or even more often while under very dusty condition DO NOT place the filter in the dishwater Installation and Operation Guide Maintenance To remove the filter gently pull upwards on the fabric tab near the top side of the unit Model H50 H70 H70B H90 Model H60 To remove the filter pull...

Page 18: ... service for changing defrost sensor Installation and Operation Guide Error Codes CODE E3 E4 E5 CAUSE Humidity Sensor Failure Water tank is Full SOLUTION Defrost Sensor Failure Change humidity sensor Empty the water inside the tank ...

Page 19: ...ng is too high Reduce setting value Air flow is restricted Make sure there is no obstacles blocking air intake or air outlet side The room temperature is too low high make sure the room temperature exceeds its allowed range Water leakage drain hose is loose reconnect the drain hose water pump failure only H90 H100 Change water pump Noise Drainage process only H90 H100 Water pump may create certain...

Page 20: ...ity 80 F 60 RH 24hrs 50 Pints 60 Pints 70 Pints Handle Wheel Power CordLength DrainHose Length Water tank 9 5 Pints 15 2 Pints 9 5 Pints Water pump Unit Dimension L W H in 23 8 18 2 36 0 18 1 20 37 9 24 9 21 5 38 2 PackagingDimension L W H in 24 0 20 4 30 1 22 8 20 9 41 1 26 3 23 3 37 1 Packaging Qty per package Net Weight lbs 73 119 102 Gross Weight lbs 82 137 115 Certificate Optional Carton 1x E...

Page 21: ... 210 220 Capacity 90 F 90 RH 24hrs 138 Pints 165 Pints 210 Pints Capacity 86 F 80 RH 24hrs 122 Pints 146 Pints 175 Pints Capacity 80 F 60 RH 24hrs 70 Pints 85 Pints 100 Pints Handle Wheel Power CordLength DrainHose Length Water tank 22 2 Pints Water pump Optional Built in Built in Unit Dimension L W H in 14 4 22 4 39 4 PackagingDimension L W H in 22 4 26 4 42 5 Packaging Qty per package Net Weight...

Page 22: ...o the finish of the case or other appearance parts caused bywear Damage caused by repairs or alterations of the unit by anyone other than those authorized by SeedMax Freight and Insurance cost for the warrantyservice Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SEEDMAX DISCLAIMS ANY LIABIL...

Page 23: ...21 NOTE ...

Page 24: ...22 NOTE ...

Page 25: ...23 NOTE ...

Page 26: ...24 NOTE ...

Page 27: ......

Page 28: ...gn and specifications herein are subject to change without notice for product improvement Contact SeedMaxTM for further details updates and other information Thank you for purchasing SeedMaxTM ECO series dehumidifier ...

Reviews: