INSTALLATION MANUAL AND USERS GUIDE 

Multi Split Series – Ductless Split – Cassette Indoor unit 

 

 

04006020101 

© Sedna Aire Europe GmbH 

12 

10/2012 

 

 

Don’t try to repair the air conditioner by yourself. It may cause an  

electric shock and kill you or damage the unit. Contact authorized service center. 

Following checks prior to contact may save you money  

Fault 

Cause analysis 

Remote controller cannot execute 
control. 

  Remote controller sometimes cannot execute control 

if the air conditioner is subject to abnormal  inter-
ference or frequent switch of functions. To resume 
normal  operation,  just pull out the power and reinsert 
it properly. 

  Is the remote control too far away from indoor unit or 

blocked by any obstacles?  

  Check the battery in remote controller for power. lf 

low power, replace the battery. 

  Check, if remote controller is damaged. 

Water leaks from indoor unit. 

 Air 

humidity 

is 

too 

high. 

 Condensing 

water 

overflows. 

  Joint of indoor unit drain pipe is loose. 

Water leaks from outdoor unit. 

  Under cooling mode, water might condense 

  on pipe or pipe joint due to cooling. 

 Defrosted 

water 

flows 

out 

under 

heating 

or 

defrost 

(auto defrost) mode. 

  Under cooling mode, water attached on heat 

exchanger will drip. 

No air blows out from indoor unit. 

  When the temperature of indoor heat exchanger is 

low during heating process, the indoor  unit will stop 
air blowing to prevent blowing of cold air (within 3 
minutes). 

  In HEAT mode: when outdoor temperature is low or 

humidity is high and much frost on the heat 
exchanger has developed, unit switches into 
automatic defrost mode. Indoor unit stops blowing air 
for 3-12 min. During this water may flow out or steam 
will appear 

  Under dehumidify  mode, the fan of  indoor unit might 

be stopped sometimes to prevent evaporation of 
condensing water and inhibit the rise of temperature 

Moisture exists on outlet grill. 
 

  lf the air conditioning is long running under high 

humidity, moisture might condense on the grill and 
drop down. 

 

In the case of following events, please contact authorized service center 

  Air conditioner gives out shrill noise during running. 

  Air conditioner gives out bad smell during running. 

 Water 

leaks 

indoors. 

  Air break switch or leakage protection switch trips 

frequently. 

  Liquids or water are poured into the machine or 

remote controller.  

 Abnormal 

overheating 

of 

power cord and plug. 

STOP THE AIR CONDITIONER AND 

PULL OUT THE POWER PLUG 

Summary of Contents for CM Multi Split Series

Page 1: ...aight forward applications where more than one indoor unit are needed The new CM Series of Sedna Aire heat pumps offers outstanding performance as well as environmental protection These models with their high efficient compressors in DC Inverter technology offer when matched with our SolarcoolTM panel efficiency rates 2 3 times better than current comparables best in class systems EER 8 for Coolin...

Page 2: ... 8 8 Care and maintenance 9 9 Trouble shooting 11 10 Location of installation 13 11 Dimensions of cassette unit 14 12 Installation of indoor cassette unit 15 13 Electrical wiring 18 14 Installation of front cover panel 18 15 Checks and test run 20 16 Warranty 20 IMPORTANT The installation and especially the connection between the outdoor unit and the Solarpanel shall be only performed by trained a...

Page 3: ... CASSETTE Composing parts System overlook Air intake Air Outlet Remote Control Drain hose Zoom in Display Timer Compressor Operation Timer Comp Oper Drainage equipment for discharging condensate water from indoor unit when cooling Drainage hose Guide louver placed in air outlet vent Connecting pipe Air inlet grille Air outlet vent Air filter purifier in air inlet grille ...

Page 4: ... attempt to repair the air conditioner by yourself Wrong repair may cause an electric shock and may kill you Don t apply cold wind over longer time on you It may cause a cold and harm your health especially over night when you sleep If your detect unusual phenomenons like smell or burning smoke turn off immediately the unit It may cause damage electrical shocks and impact your health Don t place a...

Page 5: ...running the unit It can decrease the air conditioning capacity Don t blow the air directly to and plants It may impact their health when not properly controlled Don t damage the power and signal cords Don t damage or cut the cords If this has happened contact service center or other trained and skilled electricians since wrong repairs may kill you Don t splash water on the indoor units It can caus...

Page 6: ...s displayed Press within 5 sec or to set time Every press changes time by 1 min Holding down the buttons rapidly changes the time setting by 1 min and then 10 min After having set press TIMER ON TIMER OFF within 5 sec to confirm your input 8 Display light on off Switch display light on off 9 Displays set temperature room temperature or outdoor temperature The temperature control range for the indo...

Page 7: ... The breakers act as short circuit prevention and to avoid abnormal overloads The main switch must be accessible easily and at all times Switch of power before cleaning and maintenance of the indoor units After having turned off the indoor units they will continue to work for 20 70 sec to deplete the residual cool heat in the unit s evaporator while preparing for next operation This is normal When...

Page 8: ...t will be removed after the unit has stopped This is intended to avoid mildew in the indoor unit When having set X FAN on After turning off the unit On Off button the fan in the indoor unit will continue for further 10 min If you want to stop that too press X FAN again When having set X FAN off After turning off the unit On Off button the unit will stop at once Auto Run In the AUTO mode the unit w...

Page 9: ... panel is dirty please use a cloth which is slightly moistened with warm water cleanser under 40 C then dry it and wipe off the dirty spots NOTE The indoor units contains microcomputer components and circuit board in the display which are very sensitive against water So don t put any water into the interior of the indoor unit Clean the air filters in the indoor unit at least all 6 months recommend...

Page 10: ...rifier out Install new filters in frame and reinsert purifiers in the air filter Reinsert the filter Fix the purifiers on the filter install filter on the several bulges on top of the grille Pull the handle behind the grille toward inside to fix the filter Close the air inlet grill analogue to step 1 Repetitive maintenance of indoor unit Turn power off Clean air inlet grill Clean air inlet filter ...

Page 11: ...ing running or the air conditioner is stopped sometimes you may hear hua hua or di du di du noise This is the flowing sound of refrigerant other than fault Sometimes a thin fog will flow out of the outlet when air conditioner is running in cooling mode This might occur when indoor temperature and humidity are high This is because the indoor air is quickly cooled down After a period of time the fog...

Page 12: ...ut under heating or defrost auto defrost mode Under cooling mode water attached on heat exchanger will drip No air blows out from indoor unit When the temperature of indoor heat exchanger is low during heating process the indoor unit will stop air blowing to prevent blowing of cold air within 3 minutes In HEAT mode when outdoor temperature is low or humidity is high and much frost on the heat exch...

Page 13: ... have access for routine maintenance e g replacing the filters The height of the installation should be min 1 8 m above the floor Install cassette in middle of the room to allow optimal air distribution into all corners Stay away at least 1m from other electric appliances like TV audio devices etc Do not locate the indoor unit in the immediate proximity of a laundry bath shower or swimming pool Ma...

Page 14: ... GmbH 14 10 2012 11 DIMENSIONS OF CASSETTE UNIT CMC12 CMC18 CMC24 The decorated covers of the cassette shall overlap the ceiling by min 20 mm 950 Cover of cassette 890 Ceiling opening 840 Indoor unit 680 780 950 Cover of cassette 890 Ceiling opening 840 Indoor unit Refrigerant pipe Hoisting screw 650 570 400 570 604 650 ...

Page 15: ... and lower nut gasket on rod Check helping installation cardboard with openings in ceiling Central mark of the ceiling opening is marked on the cardboard Install helping installation cardboard on unit Hang the unit onto the desired location using the rods and gaskets IMPORTANT Check if the unit is horizontal if not turn nuts until unit is horizontal If the unit is not horizontal water may leak sin...

Page 16: ...ck the connection for leakage Use water soap solution Insulate gas pipes and their connection to prevent condensation and water leaks by covering provided insulation sheet completely around the connection and nut Fasten the isolation sheet against tear off NOTE PLEASE FOLLOW THIS INSTUCTION OTHER WISE CONDENSATE DEVELOPS DROPS AND DAMAGES THE CEILING Install drain pipe hose During cooling condensa...

Page 17: ...e ceiling at a distance of 1 1 5 m by using the clamps Insert the hose into the clamp and tighten the clamp Isolate the drain hose against the clamp Isolate the hose AND the surrounding clamp against condensation When you install more cassettes connect the drain hose serial from the highest to the lowest that always a negative slope downwards exists Drain hose Drain hose Clamp Ceiling Correct Wron...

Page 18: ...f the terminal board connect the Signal wire to the 2 terminal and connect the L wire to the 3 terminal and connect the earthing wire to the earth terminal Earthing MUST be done If not it may harm and kill the user Fix the cable with the clamp the section of power cable with protective pipe into pressing groove and close the cover plate Tighten the fixing screws to clamp the connecting cable Put t...

Page 19: ...ling material 3 Screw the 4 hexagonal head screws under the latches about 15mm in The panel rises 4 Adjust the panel by turning it along the arrows shown below so that it closes all gaps 5 Tighten the screws until the sealing material between panel and indoor unit is 5 8 mm thick Make sure no gaps between ceiling and cover panel occur They are critical and can deteriorate much the cooling capacity...

Page 20: ... Model Serial No Owner s phone Owner s email Owner s signature Dealer s name Installer s name Installer s address Installer s signature stamp Limited warranty by Sedna Aire Europe Valid is the warranty claim as published on the Homepage of Sedna Aire Europe at the time of purchase date Sedna Aire hereby warrants to the consumer that all units are free from defects in materials and workmanship and ...

Reviews: