ST-HDC2PTZ
·
Quick Start Guide
14
2
In-door Mounting Applications
Before you start:
For cement wall, you need to use expansion screws to fix the mount. The mounting hole of the
expansion pipe on the wall should align with the mounting hole on the mount.
For wooden wall, you can just use the self-tapping screw to fix the mount.
2.1
5-inch Speed Dome In-ceiling Mounting
Applications
Before you start:
The in-ceiling mounting is applicable for ceiling construction. The following are mandatory
conditions for mounting:
The height of the space above the ceiling must be more than 250mm.
The thickness of the ceiling must range between 5 and 40mm.
The ceiling must be strong enough to withstand more than 4 times the weight of the dome and
its accessories.
Steps:
1.
Rotate the lower dome counterclockwise to separate it from the back box as shown in Figure 2-1.
2.
Remove the protective lens cover, foam and sticker from the dome drive.
3.
Set the address and baudrate for the HDC-TVI speed dome. Please refer to the
Section 1.2.1
5-inch Speed Dome Settings
for DIP switch settings.
4.
Attach lower dome to the back box, and rotate clockwise to secure it.
Protective Foam
Sticker
Lower Dome
Back Box
Figure 2-1
Remove the Protective Accessory
5.
Drill a hole on the ceiling according to the drill template (supplied).
±
2mm of the diameter of the circle is tolerable.