![SECURITY SENSOR ZEBRA-24.30C User Manual Download Page 29](http://html.mh-extra.com/html/security-sensor/zebra-24-30c/zebra-24-30c_user-manual_1232214029.webp)
ZEBRA-9.30, ZEBRA-9.30.BT
29
27.01.2021
2.3.6.2
The tamper button contacts can be connected with a control panel in two ways:
-
as a separate loop, in this case the customer will receive a tamper alarm as a
separate signal. The alarm will be received when the cover of the transceiver unit
is opened, even when the power supply is off;
-
series connection of tamper button contacts with relay contacts. In this case
alarms will be transmitted to one control panel by the relay actuation or opening
the cover of the transceiver unit.
2.3.6.3
To activate the Bluetooth interface on ZEBRA-9.30.BT, connect the grey wire of
the transceiver unit to “+” supply.
2.3.6.4
Figure 2.6 shows the connection diagram using the lightning guard unit and the power
supply unit.
Figure 2.6 – Connection diagram using LGU