ZEBRA-9.30, ZEBRA-9.30.BT
24
27.01.2021
2.3.5
Installation order of ZEBRA-9.30 on the protected surface.
2.3.5.1
Depending on the application task, the sensors ZEBRA-9.30 can be mounted on
brackets with overhang 500, 350 and 120 mm:
-
500 mm bracket is recommended, if the top of the fence is protected with physical
protection means (reinforced twisted barbed tape, razor wire etc.) (see Figures
2.3, 2.5);
-
350 mm bracket is recommended, if on the top of the fence there are no physical
protection means (see Figures 2.3, 2.5);
-
120 mm bracket is recommended, if the radiation direction is perpendicularly to
the supporting surface or within an angle (90
± 40
) (see Figures 2.4, 2.5).
2.3.5.2
At the selected site mark out the area in accordance with Figures 2.3, 2.4.
2.3.5.3
Fix on the wall pos. 1 the bracket pos. 2 using screws pos. 6.
2.3.5.4
Insert the bolt pos. 11 in the slot of ring pos. 8 and fasten the transceiver unit on
bracket pos. 2.
2.3.5.5
Loosen the nut pos. 9 and point the unit on the necessary direction turning it in a
horizontal surface.
2.3.5.6
Tighten the nut pos. 9.
2.3.5.7
Moving the transceiver in a vertical surface relative to the ring slot pos. 8, align the
unit in a vertical surface and tighten it with the bolt pos. 11.