Direct Programming Manual
Edge
Smart Keypads and Card Readers
26
If you need help, please email
or call
(972) 474-6390
.
Wiegand input is configured to share code list with non-Wiegand codes.
Add Sleep Code(s) on Both Wiegand Inputs
These procedures will add a sleep code or codes for Wiegand keypads, card readers, remotes, and
vehicle tag readers on both Wiegand inputs.
Quick Entry for Wiegand Keypad (uses default facility code)
This procedure will add one or more sleep codes with the default facility code for a Wiegand
keypad. Both the 26-bit and SBI Flex 64-bit formats can be used.
1251
$
6
$
102
$
1
$
XXXXX
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 102 and listen for good tone.
Enter next sub mode 1 and listen for good tone.
Enter code (26-bit: 5 digits; numbers only; max value 65535) and listen for good tone.
Repeat above step to add additional codes.
Enter # key to exit Programming Mode.
Note: This procedure will not work if any of the following are true:
One or both Wiegand inputs are disabled.
One or both Wiegand inputs are configured to share code list with non-Wiegand codes.
Each Wiegand input is configured to a different Wiegand bit format.
Quick Entry for Wiegand Card Readers, Remotes, and Vehicle Tag Readers
This procedure will add one or more sleep codes with a specified facility code for a Wiegand card
reader, remote, or vehicle tag reader. Only the 26-bit format can be used.
1251
$
6
$
102
$
2
$
XXX
$
XXXXX
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 102 and listen for good tone.
Enter next sub mode 2 and listen for good tone.
Enter 3-digit facility code and listen for good tone.
Enter 5-digit sleep code and listen for good tone.
Repeat above step to add additional codes.
Enter # key to exit Programming Mode.