Q U I C K   S TA R T

  G U I D E

QSG-27230-EN     Rev. B (2/2021)

Model

27-230 

(HID, SK)

4a

4b

IMPORTANT

r

r

CAUTION

STOP

6

7

5

If you would like to use a third-party

power source such as solar, verify that it 

conforms to the following specs:

Connect wires to unit as shown in

Step 4.

Connect wires to your power source, 

making sure you connect positive to 

positive and negative to negative.

Double check that you have wired from 

positive on the Edge unit to positive on your 

power source and negative on the Edge unit 

to negative on your power source.

Reverse polarity can damage the unit!

Input

12–24 VAC/DC

no more than 10% beyond this range

Current Draw

less than 111 mA @ 12 VDC

less than 60 mA @ 24 VDC

Using a Third-Party

Power Source (Optional)

Before going forward, double check all 

wiring and make sure the unit has power!

Wiring diagrams for connecting to accessory 

devices can be found on 

Pages 5 and 6

.

For connecting accessories not mentioned, 

please contact 

Technical Support

.

Make sure the gate or door path is clear 

before completing Step 7!

Add Access Code to Relay A.

(To add multiple codes, enter each of them before pressing pound key.)

Make sure gate or door path is clear; 

then enter access code on keypad,

and con

fi

rm gate or door opens.

Jump to 

Page 7

 to continue programming and 

download the Edge Smart Keypad app.

INSTALLATION COMPLETE!

N

1

1

1

2

5

?

?

?

?

Access Code to Be Added

(4 digits by default; numbers only)

Master Code

(can be changed)

Sub Mode

Close front panel of unit and lock it.

NOTE: The green arrow indicates a “good” tone on the Edge unit. By default, the following 

codes are reserved and cannot be used: 1251, 1273, 1366, 1381, 1387, 1678, 1752, and 1985.

Summary of Contents for 27-230

Page 1: ...FORE OPERATING REVERSING OR OTHER SAFETY DEVICES SHOULD ALWAYS BE USED Edge Unit HID version shown Key Carriage Bolt 4x Hex Nut 4x 12 V AC DC Adapter PS 12DC1 Mount unit to pedestal using included mou...

Page 2: ...pen Wiring cabling not shown for clarity Wiegand Terminals For wiring to Wiegand devices See Page 6 Reset Button For performing unit reset Power Relay Event Terminals For wiring to power wiring to gat...

Page 3: ...vent Terminals Gate Operator Door Opener POWER POWER COM RADIO COM REVERSE LOOP STOP CLOSE The GROUND terminal is optional unless required by local code s If using please connect to earth ground or eq...

Page 4: ...Third Party Power Source Optional Before going forward double check all wiring and make sure the unit has power Wiring diagrams for connecting to accessory devices can be found on Pages 5 and 6 For co...

Page 5: ...Door Switch Event Inputs Wiring for accessories such as a request to exit device RELAY A J10 RELAY B J11 12 24 VAC DC POWER J3 J9 J5 EVENT INPUTS Edge Power Relay Event Terminals N C N C COM N O GND...

Page 6: ...ADER WIEGAND 2 Wiegand Device WIEGAND OUTPUTS 12V GND LED 1 LED 2 DATA 0 DATA 1 Disconnect power to the Edge unit before connecting Wiegand devices Failure to disconnect power can damage the unit Wieg...

Page 7: ...r Edge unit is powered on and that Bluetooth is enabled on your mobile device or pairing will not work Step 1 Grab your mobile device and open the Edge Smart Keypad app If you do not have the app foll...

Page 8: ...s default Sub Mode A Sub Mode B 4 4 1 1 2 5 Sleep Code 4 digits numbers only Master Code 1251 is default Change Sleep Code Change Master Code Highly recommended for security purposes Programming Sub M...

Page 9: ...0 second lockdown for 90 seconds when an incorrect code is entered three times Current State On 1 beep O 2 beeps 1 1 2 5 Master Code 1251 is default Sub Mode A Sub Mode B 7 4 Configure 1 for no change...

Page 10: ...Relay A or Relay B when event input state changes from normally open N O to normally closed N C Mode 2 Log Mode Makes log entry of event input state when event input state changes from normally open...

Page 11: ...bled 1 1 2 5 Master Code 1251 is default Sub Mode A Sub Mode B 9 4 Event Mode 0 Current State Unit beeps mode number or good tone when disabled 1 1 2 5 Master Code 1251 is default Sub Mode A Sub Mode...

Page 12: ...or good tone before moving on Configure Wiegand Input Allows enabling or disabling of a Wiegand input and configuration of the Wiegand device type For the tag reader type use the Edge Smart Keypad app...

Page 13: ...to Be Added 4 digits by default numbers only Master Code 1251 is default Add Latch Code to Relay A Add Limited Use Code Access codes can be given a use or time restriction For more advanced time rest...

Page 14: ...s to Be Added 5 digits by default numbers only Master Code 1251 is default Relay 100 for A 104 for B On Wiegand Input 1 or 2 On Both Wiegand Inputs Green arrow indicates good tone on unit Always wait...

Page 15: ...put 1 for 1 2 for 2 6 1 Sub Mode B 1 1 2 5 Code s to Be Added 5 digits by default numbers only Master Code 1251 is default Relay 103 for A 105 for B On Wiegand Input 1 or 2 On Both Wiegand Inputs Sub...

Page 16: ...e B 2 1 2 5 Code s to Be Added 5 digits 00000 to 65535 Master Code 1251 is default Add Wiegand Card Remote Vehicle Tag Access Code s To add multiple codes enter each of them before pressing pound key...

Page 17: ...ts 00000 to 65535 Master Code 1251 is default Add Wiegand Card Remote Vehicle Tag Latch Code s To add multiple codes enter each of them before pressing pound key Facility Code Relay 103 for A 105 for...

Page 18: ...de C 2 1 2 5 Code s to Be Added 5 digits 00000 to 65535 Master Code 1251 is default Add Wiegand Card Remote Vehicle Tag Manager Access Code s To add multiple codes enter each of them before pressing p...

Page 19: ...ed 5 digits 00000 to 65535 Master Code 1251 is default Delete Wiegand Card Remote Vehicle Tag Manager Code s To add multiple codes enter each of them before pressing pound key Facility Code 0 2 0 Sub...

Page 20: ...nc All rights reserved 20 of 20 QSG 27230 EN Rev B 2 2021 Q UICK STA RT GU I DE Model 27 230 HID SK Call 972 474 6390 Email techsupport securitybrandsinc com We are available Mon Fri 8am 5pm Central E...

Reviews: