Connect electrical wiring according to the local appropriate wiring rules. Make sure
the correct voltage on the PCB has been selected prior to turning on the power.
Failure to do this could damage the unit. Factory default voltage is set to 12volts DC.
Note: If a door closer has been fitted then adjust it so that the armature closes
lightly against the magnet. This will avoid damage to the magnet and will also
make the door operation quieter.
The Maglock lock does not require much ongoing maintenance. The custom-
er should be advised to keep the mating faces of the armature and magnet
clean making sure that no abrasive materials are used to clean the faces.
Do not spray the magnet or armature with any
chemicals such as lacquer as the release of the Maglock may
be compromised.
6
7
MOUNTING THE ARMATURE
HOLLOW CORE
DOOR ENLARGE
HOLE TO 5/8in
[16mm]
SOLID CORE
DOOR ENLARGE
HOLE TO 15/32in
[12mm]
MOUNTING ARMATURE
ON DIFFERENT DOOR TYPES
•
Ensure the armature and magnet
are aligned. Adjust the mounting plate
to suit and then drill the appropriate
sized holes in the door header for the
remaining attachment screws.
MOUNTING THE MAGLOCK
MOUNTING WITH Z BRACKET KITS
Assemble Z Bracket kit as shown
MOUNTING ON GLASS DOORS
ELECTRICAL CONNECTION
MAINTENANCE
VM1 Rev. C
REINFORCED
DOOR
TAP 1/4-20 VM600
[M6 X 1.25”]
TAP 5/16-18 VM1200
[M8 X 1.25]
For complete Vista Maglock
Warranty information, please visit
www.securitron.com/vista.
•
Align the armature plate on the door using sight or the template supplied.
•
Mark and drill holes then mount the armature to the door. Make sure that the
armature plate is not over tightened and that it is installed as shown in the
following diagram. The armature plate must be free to self align with the door.
Adjust position of
Magnet relative to
the Armature as shown
Assemble Glass Door
Brackets as shown