Radio 

RF frequency – 
Europe & UK: 868.42MHz
ANZ:

921.42MHz 

RF range:

100m line of sight in open air

Class:

3

Inclusion:

If the Z-Wave controller does not 
respond within 2-seconds then the 
SSP 301 will try with NWI 
(Network Wide Inclusion). The 
total process can take up to 20 
seconds.

This is a Z-Wave certified product and can be used 
with Z-Wave controllers that support its 
functionality. Please refer to the documentation 
provided by the gateway or controller manufacturer. 
See the Z-Wave alliance website 

www.z-wavealliance.org

 for certified controllers.

EN 60730-1 
R&TTE directive
BS 1363-3 (for UK)
IEC 60884-1 (for EU)
ETSI EN 300 220-2, EN 301 489 part 1 & 3
AS/NZS 3122 and RCM ACMA (for ANZ)

Compliance

 

HS

R

O

18

Summary of Contents for SSP 301

Page 1: ...SSP 301 Z Wave Switch and Repeater 1 User and Installation Instructions BGX501 920 R03...

Page 2: ...d repeater that forms part of a Z Wave Plus home automation network The SSP 301 is a mains powered device that will switch power On Off a connected appliance either by the Z Wave network or manually b...

Page 3: ...all socket Ensure that the red coloured network status LED is flashing once per second Note If the network status LED is not flashing check the following Ensure that the wall socket switch is on Press...

Page 4: ...fere with the low power radio signals between the unit and the controller Step 2 Including and Excluding a Device To include the SSP 301 onto a network put the controller into inclusion mode Now press...

Page 5: ...y default state and the Network status LED will start flashing once per second If there is an issue with RF communication re locate the device and repeat the inclusion process To exclude the SSP 301 f...

Page 6: ...ciate Always check with the manufacturer s manual Step 4 Identify the device to the controller by sending the node information to do this press and hold the SSP 301 button for more than 1 second but l...

Page 7: ...n LED will be lit when the supply is On The socket type will vary with country The figure shows the UK variant Ensure that the appliance plug is firmly plugged into the appliance socket 7 Combined But...

Page 8: ...onds 7 11 Seconds Toggles supply to socket outlet Send NIF used for Association Inclusion exclusion SSP 301 resets to factory default Refer Device Reset Locally command class Toggles green LED NA Red...

Page 9: ...Basic Routing Slave Implemented Device Class Command Class Commands Supported Mapped on Binary Switch Command class V1 Binary switch V1 Get Manufacturer Specific V2 Manufacturer ID 0x0059 Product Typ...

Page 10: ...ed Groupings Report Specific Group Get Command Specific Group Report Command Product supports one association group that have maximum of 4 nodes Set Get Report Configuration V1 10 Report Device Reset...

Page 11: ...old the button for 7 11 seconds within the 60 seconds of power cycle to put the device in factory default It reset all configuration and association to factory default It also removes the device from...

Page 12: ...er Icon ICON_TYPE_GENERIC_ON_OFF_POWER_SWITCH Power Level V1 Power Level Set Power Level Get Power Level Report Power Level Test Node Set Power Level Test Node Get Power Level Test Node Report Note Fo...

Page 13: ...eded to set a value 36000 65536 29536 3 Relay LED configuration NA 1 3 0 Refer Table Relay and green LED configuration for details Common attributes Minimum Value is zero for above parameters Zero con...

Page 14: ...r Relay Close OFF for Relay Open 1 Retain last status over the power cycle ON for Relay Close OFF for Relay Open 2 Open ON for Relay Open OFF for Relay Close 3 Retain last status over the power cycle...

Page 15: ...e node is associated to it In that situation if there is no Communication Acknowledge with any associated device in the network for more than one hour the device will indicate a communication fail sta...

Page 16: ...3 A EU 16 A 0 4 3 A ANZ 10 A 0 4 3 A Control type Micro disconnection Control action Type 1B Software class Class A Burden 1W in standby Mechanical Dimensions WxDxH UK 60 x 61 x 119mm EU 60 x 95 x 11...

Page 17: ...e use Mounting UK Type G EU Schuko Type E Type F ANZ Type I Ball Pressure Test Temperature 75 C Environmental Impulse voltage rating Cat II 2500V Storage temperature 20 C to 55 C Operating temperature...

Page 18: ...take up to 20 seconds This is a Z Wave certified product and can be used with Z Wave controllers that support its functionality Please refer to the documentation provided by the gateway or controller...

Page 19: ...w securetogether com European Sales Office CEWE Instrument AB Box 1006 611 31 Nyk ping t 46 8 600 80 60 e info securetogether com www securetogether com Australia Sales Office Secure Australasia Pty L...

Page 20: ...India p 91 294 2492 300 05 f 91 294 2492 310 e mktg securetogether com www securetogether com Elegant Metering Solutions FZE 4EA 326 P O Box 54857 Dubai Airport Free Zone Dubai UAE p 971 50 6575166 f...

Reviews: