Frequentlty Asked Questions (FAQs) 

Q.

 What indicates that a sensor is disconnected? 

Ans.

 If a sensor is disconnected then the parameter value will be shown as “SENSOR DISCONNECT” on the 

display as shown below. 

 

 

Q.

 The value of Pump Efficiency, Flow Rate and Total Head is displayed as zero. 

Ans.

 View the 

Online Data 

screen of Pump Test 9 and verify the following: 

 

Ensure that sensors are not disconnected. 

 

Ensure that the power meter is communicating with Censeo. 

 

Q.

 What indicates that the communication cable between power meter and Censeo is disconnected? 

Ans. 

If the communication cable between power meter and Censeo is disconnected, the values of motor/ 

generator parameters on Page 3 will be displayed as zero.

 

 

Q.

 How to verify that the power meter is ON and is responding? 

Ans. 

If the power meter is ON and is responding, the values of motor/ generator parameters displayed on   

Page 3 will be non-zero as shown below. 

 

 

Q.

 How to verify the baud rates of the communication channels? 

Ans.

 To verify the baud rates of the communication channels, press Up (

) and Down (

) buttons 

simultaneously for 5 seconds, Censeo displays meter information. The baud rate of power meter communication 
port, baud rate of RS485 communication port and baud rate of the optical port are shown on the second page of 
meter information displays.

 

 

 

Q.

 How to verify the firmware version? 

Ans. 

To verify the firmware version, press the Up (

) and Down (

) buttons simultaneously for 5 seconds. 

The firmware version is shown on the first page of meter information displays.

 

 

 

Summary of Contents for BGX501-806-R02

Page 1: ...Real time Pump Hydro Turbine Blower Performance Monitoring with Censeo User Manual BGX501 806 R02...

Page 2: ...Page 2 of 20 BGX501 806 R02 Censeo User Manual Public Copyright 2013 SIHPL...

Page 3: ...Flow Measurement 7 4 3 Connection Diagram 7 4 4 Parts Description 8 5 Firmware Features 9 5 1 Principle of Operation 9 5 2 Benefits 10 5 3 What does Censeo Measure 10 5 4 Input and output 10 5 5 Keys...

Page 4: ...products such as but not limited to the following Incomplete or incorrect installation or maintenance Connection to incorrect voltage sources Damaged insulation on connecting cables Contact with hazar...

Page 5: ...such as Censeo time communication displays historical data analogue outputs alarms and relays Besides configuring Censeo Pump Test 9 is also used for viewing online data reading historical data alarms...

Page 6: ...ency 1 Flow 1 Max pressure head 5 bar Max air outlet temperature 150 C with a maximum variation of 120 C between inlet and outlet Dimensions mm 144 H x 144 W x 172 D Weight 1 200 kg Mounting type Proj...

Page 7: ...Transmit and Receive lines for PC over RS485 Pdi Discharge Outlet Pressure Sensor TX2 RX2 Transmit and Receive lines for Power Meters over RS485 Tsi Suction Inlet Temperature Sensor Blue IO1 4 Analog...

Page 8: ...splay with backlight 2 PACT port Available at the bottom left corner of the front plate the PACT port is used to configure the meter on demand through RS232 communication from a computer with the help...

Page 9: ...n terminals These terminals are used to feed real time RS485 inputs from external electronic wattmeters or power meters which measure the power drawn generated by the pump hydro turbine blower in real...

Page 10: ...with a computer and communicate the same over various communication technologies and to interface with complex Control And Data Acquisition CADA systems 5 3 What does Censeo Measure Censeo accepts in...

Page 11: ...tage B Phase 14 Current R Phase 15 Current Y Phase 16 Current B Phase 17 Frequency 18 Average Power Factor 19 Analogue Input 1 20 Analogue Input 2 21 Analogue Input 3 22 Analogue Input 4 23 Analogue I...

Page 12: ...o scroll can be stopped at desired display as shown in the Table 3 2 3 These pages are not set up for auto scroll by default Up to 4 parameters can be defined for pages 2 and 3 4 This page is used onl...

Page 13: ...ation method Blower efficiency using Polytropic efficiency calculation method Flow rate for pump hydro turbine Flow rate for blower Suction pressure for pump Inlet pressure for hydro turbine blower Di...

Page 14: ...or hydro turbine Shaft Power Overall efficiency Voltage R Phase Current R Phase Voltage Y Phase Current Y Phase Voltage B Phase Current B Phase Frequency Average Power Factor Motor Efficiency for pump...

Page 15: ...can be configured through software and these are shown as mentioned The available pump parameters for Page 2 display are as follows Pump Parameter Name Display Efficiency EF Flow Rate QP Total Head T...

Page 16: ...ate QM Overall Efficiency OE Inlet Pressure PI Outlet Pressure PO Inlet Temperature TI Differential Temperature DT Total Head TH Table 7 Available Blower Parameters for Page 2 display in Censeo 5 6 4...

Page 17: ...configured BL Below limit AL Above limit OR Out of range IR In range Table 9 Index for Alarm page in Censeo 5 7 Cumulative Flow Cumulative flow for pump hydro turbine blower is calculated by the conn...

Page 18: ...Test9 based on filter value i e averaging period and the parameter value s difference with the defined limit at the time of event this is in view of slow varying nature of thermal parameters like tem...

Page 19: ...the values of motor generator parameters on Page 3 will be displayed as zero Q How to verify that the power meter is ON and is responding Ans If the power meter is ON and is responding the values of...

Page 20: ...Ltd 258 Darebin Road Fairfield VIC 3078 Australia p 61 3 9485 6000 f 61 3 9485 6099 Cewe Instrument AB SE 611 29 Box 1006 Nyk ping Sweden p 46 155 775 00 f 46 155 775 97 Secure Controls UK Ltd South...

Reviews: