Volumetric flow 
rate 

cubic metres per second 
(m3/sec) 

13 

Density 

gram per cubic metre 
(g/m3) 

litre per second (l/sec) 

kilogram per cubic metre 
(kg/m3) 

cubic metres per hour 
(m3/hr) 

14 

Other 

NA 

gallons per day (gal/day) 

million litres per day 
(Ml/day) 

Table 1: Available software configurable parameters in Censeo for analogue inputs with units 

The possible parameter assignments for Censeo outputs are as follows: 

S. No. 

Description 

S. No. 

Description 

1.   

Efficiency (Pump / Hydro-Turbine / 
Blower) 

2.   

Flow Rate 

3.   

Total Head 

4.   

Drive Power/ Generated Power 

5.   

Overall Efficiency 

6.   

Discharge Pressure/ Outlet Pressure 

7.   

Suction Pressure/ Inlet Pressure 

8.   

Velocity Head 

9.   

Suction Temperature/ Inlet 
Temperature 

10.   

Differential Temperature 

11.   

Voltage R-Phase 

12.   

Voltage Y-Phase 

13.   

Voltage B-Phase 

14.   

Current R-Phase 

15.   

Current Y-Phase 

16.   

Current B-Phase 

17.   

Frequency 

18.   

Average Power Factor 

19.   

Analogue Input 1 

20.   

Analogue Input 2 

21.   

Analogue Input 3 

22.   

Analogue Input 4 

23.   

Analogue Input 5 

24.   

Analogue Input 6 

25.   

Analogue Input 7 

26.   

Analogue Input 8 

Table 2: Available software configurable parameters in Censeo for analogue outputs 

 

5.5  Keys 

The four keys available on Censeo are used for the following functions: 

Key 

Function 

Description 

Key press 

 

next 

When pressed once, the display scrolls to the next one 
available in the sequence. 

Short 

 

previous 

When pressed once, the display scrolls to the previous one 
available in the sequence. 

Short 

 

up 

When pressed once, the display scrolls to the next display 
page available in the sequence. 

Short 

 

down 

When pressed once, the display scrolls to the previous 
display page available in the sequence. 

Short 

 

Reset 
display 

When these buttons are pressed simultaneously for 5 
seconds, Censeo reset the display page to show first-page, 
first-display. 
 

Long (5 sec) 

Summary of Contents for BGX501-806-R02

Page 1: ...Real time Pump Hydro Turbine Blower Performance Monitoring with Censeo User Manual BGX501 806 R02...

Page 2: ...Page 2 of 20 BGX501 806 R02 Censeo User Manual Public Copyright 2013 SIHPL...

Page 3: ...Flow Measurement 7 4 3 Connection Diagram 7 4 4 Parts Description 8 5 Firmware Features 9 5 1 Principle of Operation 9 5 2 Benefits 10 5 3 What does Censeo Measure 10 5 4 Input and output 10 5 5 Keys...

Page 4: ...products such as but not limited to the following Incomplete or incorrect installation or maintenance Connection to incorrect voltage sources Damaged insulation on connecting cables Contact with hazar...

Page 5: ...such as Censeo time communication displays historical data analogue outputs alarms and relays Besides configuring Censeo Pump Test 9 is also used for viewing online data reading historical data alarms...

Page 6: ...ency 1 Flow 1 Max pressure head 5 bar Max air outlet temperature 150 C with a maximum variation of 120 C between inlet and outlet Dimensions mm 144 H x 144 W x 172 D Weight 1 200 kg Mounting type Proj...

Page 7: ...Transmit and Receive lines for PC over RS485 Pdi Discharge Outlet Pressure Sensor TX2 RX2 Transmit and Receive lines for Power Meters over RS485 Tsi Suction Inlet Temperature Sensor Blue IO1 4 Analog...

Page 8: ...splay with backlight 2 PACT port Available at the bottom left corner of the front plate the PACT port is used to configure the meter on demand through RS232 communication from a computer with the help...

Page 9: ...n terminals These terminals are used to feed real time RS485 inputs from external electronic wattmeters or power meters which measure the power drawn generated by the pump hydro turbine blower in real...

Page 10: ...with a computer and communicate the same over various communication technologies and to interface with complex Control And Data Acquisition CADA systems 5 3 What does Censeo Measure Censeo accepts in...

Page 11: ...tage B Phase 14 Current R Phase 15 Current Y Phase 16 Current B Phase 17 Frequency 18 Average Power Factor 19 Analogue Input 1 20 Analogue Input 2 21 Analogue Input 3 22 Analogue Input 4 23 Analogue I...

Page 12: ...o scroll can be stopped at desired display as shown in the Table 3 2 3 These pages are not set up for auto scroll by default Up to 4 parameters can be defined for pages 2 and 3 4 This page is used onl...

Page 13: ...ation method Blower efficiency using Polytropic efficiency calculation method Flow rate for pump hydro turbine Flow rate for blower Suction pressure for pump Inlet pressure for hydro turbine blower Di...

Page 14: ...or hydro turbine Shaft Power Overall efficiency Voltage R Phase Current R Phase Voltage Y Phase Current Y Phase Voltage B Phase Current B Phase Frequency Average Power Factor Motor Efficiency for pump...

Page 15: ...can be configured through software and these are shown as mentioned The available pump parameters for Page 2 display are as follows Pump Parameter Name Display Efficiency EF Flow Rate QP Total Head T...

Page 16: ...ate QM Overall Efficiency OE Inlet Pressure PI Outlet Pressure PO Inlet Temperature TI Differential Temperature DT Total Head TH Table 7 Available Blower Parameters for Page 2 display in Censeo 5 6 4...

Page 17: ...configured BL Below limit AL Above limit OR Out of range IR In range Table 9 Index for Alarm page in Censeo 5 7 Cumulative Flow Cumulative flow for pump hydro turbine blower is calculated by the conn...

Page 18: ...Test9 based on filter value i e averaging period and the parameter value s difference with the defined limit at the time of event this is in view of slow varying nature of thermal parameters like tem...

Page 19: ...the values of motor generator parameters on Page 3 will be displayed as zero Q How to verify that the power meter is ON and is responding Ans If the power meter is ON and is responding the values of...

Page 20: ...Ltd 258 Darebin Road Fairfield VIC 3078 Australia p 61 3 9485 6000 f 61 3 9485 6099 Cewe Instrument AB SE 611 29 Box 1006 Nyk ping Sweden p 46 155 775 00 f 46 155 775 97 Secure Controls UK Ltd South...

Reviews: