background image

2

598-1158-01

INSTALLATION

For easy installation, select an existing light with a wall 
switch for replacement.

W

IRE

 

THE

 L

IGHT

 C

ONTROL

❒ 

Turn power off at the fuse or circuit breaker.

❒ 

Remove the existing light fixture.

  Install the mounting strap as shown using two screws 

that fit your junction box.

  The plastic hanger can be used to hold the fixture 

while  wiring. The  small  end  of  the  plastic  hanger 
can be threaded through the hole in the center of 
the cover plate. The small end then goes into one 
of the slots on the mounting strap.

❒ 

Route the Light Control’s wires through the large 
gasket holes.

 

  Twist the

 

junction box wires and fixture wires together 

as shown. Secure with wire connectors.

M

OUNT

 

THE

 L

IGHT

 C

ONTROL

  Align the Light Control cover plate and cover plate 

gasket. Secure with the mounting bolt.

  Align the three slots in the decorative shell with the 

lamp holder pins. Push the shell in and then twist 
clockwise to lock. Repeat for other shell.

Lock Nut

To  avoid  water  damage  and 
electrical  shock,  keep  lamp 
holders 30° below horizontal.

For eave mount only:

 Swing the sensor head towards the clamp screw 

joint. 

If  the  sensor  pops  out  of  the  ball  joint,  loosen  the 
clamp screw and push the sensor back into the ball 
joint. Tighten the clamp screw when done.

 Then rotate the sensor head clockwise 180° so the 

controls face down.

Controls

Wall Mount

Eave Mount

For under eave installation, the sensor head must 
be rotated

 as shown in the next two steps for proper 

operation and to avoid the risk of electrical shock.

Controls

Controls

Clamp Screw

❒ 

Adjust the lamp holders by loosening the lock nuts 
but do not rotate the lamp holders more than 180° 
from  the  factory  setting.  When  screwing  in  the 
floodlamps, do not overtighten.

Keep lamps at least 
1" (2.5 cm) from the 
sensor. Do not allow 
the  lamps  to  block 
the lens.

Lens

  Push the Rubber Plug firmly into place.

  If a wet location junction box was not used, caulk 

the  wall  plate  mounting  surface  with  silicone 
weather sealant.

Shell Slot

White

 to 

White

Black

 to 

Black

Junction box ground wire to 
green ground screw on fixture.

Gasket

Mounting 

Strap

Mounting 

Bolt

Rubber 

Plug

Summary of Contents for SH-5412

Page 1: ...de at dawn Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate MANUAL MODE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 10 minute position Put the ON TIME switch on the bottom of the sensor in the TEST position Manual mode only works at night because daylight returns the sensor to AUTO Flipthelightswit...

Page 2: ...void water damage and electrical shock keep lamp holders 30 below horizontal For eave mount only Swing the sensor head towards the clamp screw joint If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Then rotate the sensor head clockwise 180 so the controls face down Controls Wall Mount Eave Mount For under...

Page 3: ...ng Modes TEST AUTO and MANUAL MODE Time Delay 1 5 10 minutes Range Adjustable DESA Specialty Products reserves the right to dis continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold Maximum Range Maximum Coverage Angle NOTE Sensor has a 1 1 2 minute warm up period before it will detect motion When first tur...

Page 4: ...ECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIRORREPLACEMENTSHALLBETHESOLEREMEDYOFTHECUSTOMERANDTHERESHALLBENOLIABILITY ON THE PART OF DESA SPECIALTY Products FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORE SEEABLE Some states or provinces do not allow the exclusion o...

Page 5: ... interruptor de tiempo ON TIME en la posición de 1 5 ó 10 minutos Ponga el interruptor de tiempo ON TIME al fondo del detector en la posición de prueba TEST El modo manual funciona sólo por la noche porque la luz del día pone al detector en modo AUTOMATICO Apague el interruptor por un segundo y vuélvaloaprenderparaconmutarentre MODO AUTOMATICO y MANUAL El modo manual funciona sólo con el interrupt...

Page 6: ...be ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque eléctrico Controles Controles Tornillo Sujetador Ajuste los portalámparas aflojando las contratuer cas pero no los gire más de 180 de la calibración hecha en fábrica Cuando atornille los proyectores no los apriete demasiado Mantenga las lámparas por lo menos a 2 5 cm deldetector Nodejeque laslámparasbloquee...

Page 7: ...ty Products se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de tener que incorporar nuevas características en los productos vendidos con anterioridad Alcance Máximo Angulo de Cobertura Máxima NOTA El detector tiene un período de cerca de 1 1 2 minutos de calentamiento antes de detectar movimiento Cuando lo prenda p...

Page 8: ...te el día La luz se prende sin ninguna razón aparente POSIBLE CAUSA 1 El interruptor de luz está apaga do 2 El faro está flojo o fundido 3 El fusible está quemado o el cortacircuitos está apagado 4 La desconexión de luz del día estáenefecto Compruébelocu ando comience la obscuridad 5 Alambrado incorrecto si ésta es una nueva instalación 6 No está apuntando correcta mente Apunte de nuevo el detector...