ScanLogic B22
Operation Instructions
2
1.0 System Installation
1.1 System Components
The system consists of (1) EntryPad – Part # FPC-1701A-B22 plus (1) Lock body as follows:
SwingBolt – Part # EL-0601 (not recommended as door closed notifications will not be accurate)
SwingBolt with Status– Part # EL-0601-S
DeadBolt – Part # EL-0701
SpringBolt – Part #EL-0801
1.2 Pairing the EntryPad and the Lock
SECURAM safe lock systems can operate in two different modes depending upon the type of EntryPad
being used with the lock body. The ScanLogic B22 is a digital lock system and therefore the lock must
also be programmed in digital mode. Both modes follow the same steps to reset / set which is done by
following the steps detailed below:
Step 1: Ensure the battery is connected to the Entry Pad.
Step 2: Ensure the lock cable is disconnected from the lock body.
Step 3: Locate the Reset Hole on the back of the lock (under the QC sticker).
Step 4: Using a paper clip press the reset button, inside the reset hole, 3 times to dissipate any
latent energy in the lock.
Step 5: Now press the reset button and hold.
Step 6: While continuing to press the reset button, connect the lock cable to the lock body.
Step 7: Continue to hold down the reset button for 5 seconds and then release.
Step 8: Verify that the pairing is complete by opening the lock with the default code 111111.
Step 9: Press any button on the EntryPad to initiate a lock communication test. The EntryPad
will display the following information:
Followed by:
Enter a valid code to test the lock.
The Default codes are as follows:
Super Code* (ID00) is 111111
Manager Code (ID01) is 123456
To open, enter the default code followed by pressing the Menu/Ok button.