Design
Display
Number keys
The numbers “1“ - “0“ are used for input e.g. when entering the code.
“
Func“ key
Multifunction key which adapts to perform several functions, including; Go
back one menu level, delete a entered character, show the Main menu. The
display shows the current function of the key (see section 3).
“
On/Enter“ key
The “On/Enter“ key starts the system or selects the current menu item.
“1“ key
The key can be used to scroll up if there are several menu options.
If this is possible, the display shows this (see section 3).
“2“ key
The key can be used to scroll down if there are several menu options.
If this is possible, the display shows this (see section 3).
Dear customer,
Thank you for choosing a lock with a SECU Selo – B V.2 electronic.
This electronic lock is certified according to ECB Class B.
You have purchased a product that meets extremely high security requirements
and was developed and produced according to current technical standards.
This lock is certified according to EN 1300: 2018. (Classification of high-security
locks according to their resistance to unauthorised opening).
Important: Please read the entire instruction manual before programming
and keep this manual safe so that you can revisit it at a later date.
We hope you enjoy your new SECU lock.
Your SECU Sicherheitsprodukte GmbH
Activation
Languages
The electronics are switched on using the
key on the keyboard. This then
lights up. At the same time, the display shows the SECU logo for a moment
before the input graphic for the pin code appears.
The menu navigation in the display is available in twelve languages and can be
set via the “Languages” menu. Please refer to chapter “Menu Language“ for a
detailed explanation.
General information
Blocking times
Increasing burglary protection
To protect against tampering, the lock electronics block access to the safe for
five minutes if an incorrect pin code has been entered three times in succession.
Then, for every further incorrect entry, ten minutes. During this blocking time,
the remaining time on the display runs countsdown. It is not possible to open
the safe during this period, even with a valid user or administrator code.
Please take care to ensure codes do not fall into the wrong hands. Therefore,
store the codes in a safe location so that they can only be accessed by author-
ised persons. In the event you lose a code, the lock must be set to a new code.
• The factory code must be changed as soon as the lock is commissioned
• Codes that are easy to guess (e.g. 1, -2, -3, -4, -5, -6) must not be used
• Personal data (e.g. birthdays) or other data that may be guessed with
knowledge of the code owner must not be used as a code
• After changing the code, the lock must be checked several times with the
safety door opened
Attention:
All changes to the administrator code, the factory code and the
user code must be carried out with the safe door open! After changing a code,
the lock must be operated several times with the new code with the safe door
open.
Input options
Number keys:
The numbers “1“ - “0“ are used for input e.g. when
entering the code.
“Func“ key:
Multifunction key which adapts to perform several
functions, including; Go back one menu level,
delete a entered character, show the Main menu. The display shows the current
function of the key.
“On/Enter“ key:
The “On/Enter“ button starts the system or selects the current menu item.
Keys “1“ and “2“:
In menus, you can scroll up and down using these keys.
If this is possible, the display shows this with the corresponding arrows.