background image

 

12 

 

ADMINISTRATION BY MOBILE PHONE 

 

To  operate  the  device  using  SMS,  it  is  necessary  to  first  send  the  following  SMS  “AD  ADMINISTRATOR 
+420XXXXXXXXX”, where Xs represent your phone number. Doing this, you create the main administrator, 

which there can be only one. Next user must be added into a group. Default settings includes 3 groups: 
 

Admin: 

Can write and read using SMS and control the key by calling 

Readonly: 

Can read the key’s settings using SMS and control the key by calling

 

Guest: 

Can only control the key by calling 

 
More groups can be 

added in PC’s administration interface.

 

 
The key can be operated by 

calling the key’s phone number. The key can be operated only by saved users.

  

 

 

 

When administering via a mobile phone, please follow the shown SMS format (exact text 
of orders, empty spaces, etc.). In order to send one or more orders in one SMS, divide 
them by a semi-colon.  
 
In order to make the administration as easy as possible, we recommend using the GSM 
key app for Android and iOS, which you can download free of charge from Google Play 
and AppStore.  
 

ADMINISTRATION OF USERS 

 

Action 

SMS Template 

Example of SMS 

Description  

Adding a new user 

AD name phone 
number 

AD Jones +4201234569056 

User´s name 

and phone 
number 

Removing a user 

DE name 

DE Jones 

User´s name 

Updated list of users 

LS 

LS 

 

Deleting telephone list 

CL 

CL 

 

Number of telephone list 
items 

GT  PBS 

GT  PBS 

 

ADMINISTRATION OF EVENT REGISTER 

 

Action 

SMS Template 

Example of 
SMS 

Description 

Check event register 

RG=number 

RG=10 

Number of requested logs 

Clear even register 

RC 

RC 

 

Summary of Contents for GSM Key LITE 3

Page 1: ...1 ...

Page 2: ... MOBILE PHONE 12 ADMINISTRATION OF USERS 12 ADMINISTRATION OF MANUFACTURER S SETTING 12 ADMINISTRATION OF INPUTS AND OUTPUTS 13 TECHNICAL DESCRIPTION OF INTERFACE CHYBA ZÁLOŽKA NENÍ DEFINOVÁNA FRONT CHYBA ZÁLOŽKA NENÍ DEFINOVÁNA BACK CHYBA ZÁLOŽKA NENÍ DEFINOVÁNA SIM CHYBA ZÁLOŽKA NENÍ DEFINOVÁNA LED DIODES INFORMATION ABOUT GSM KEY STATUS CHYBA ZÁLOŽKA NENÍ DEFINOVÁNA PWR CHYBA ZÁLOŽKA NENÍ DEFIN...

Page 3: ...adio parameters ČSN ETSI EN 301 511 V7 0 1 Czech Standard and declare that the above product can be used under conditions of usual use as specified in the Instructions for Use The conformity has been assessed according to 3 section 1 letter b Amendment No 3 to the Governmental Decree No 426 2000 Coll stipulating technical requirements for radio and telecommunication end devices and equipment furth...

Page 4: ...es see chapter RECOMMENDED ACCESSORIES to avoid damaging the device property or violating relevant regulations The recommended accessories have been tested and their functioning is compatible with the device The warranty however does not cover such accessories We recommend making a suitable copy or back up of important settings which are stored on your SIM card Do not open the device Only the SIM ...

Page 5: ...M Key PROFI 3 2 1 GSM hinged antenna gain of 2 dB 3 1 2 pin WAGO terminal box 4 1 13 pin WAGO terminal box 5 1 WAGO terminal box tool 6 1 Ethernet cable 7 1 Instructions for Use EN 8 1 Quick start guide 9 1 Warranty Certificate ...

Page 6: ... call is declined the operation of the gate is free GSM Key LITE 3 is suitable for family houses and small companies with up to 20 users and is administered by an Android or iOS mobile phone app or configuration SMS GSM key PROFI 3 is suitable for middle size and large companies office buildings hotels and guest houses with up to 1000 user It can control to four devices and is administered by an A...

Page 7: ...ll save their phone numbers using software in the GSM key After guests leave the administrator will remove guests telephone numbers By using the GSM key you avoid the risk of losing or damaging remote controls The software enables easy and systematic monitoring of several devices at the same time and the maintenance of a perfect overview of settings and users of individual gates ENTRANCE TO COMPAN...

Page 8: ...ELV circuits also it must comply with EN60950 The power supply which is a part of the package complies with such requirements If batteries or accumulators are used these must also comply with relevant standards 4 Should you have any questions do not hesitate to contact your installation company or SECTRON Hotline hotline sectron cz 420 599 509 599 To install the device you will need pincers Insert...

Page 9: ...you use a VPN service the displayed number of the caller may be different Ask your provider for more information The device is designed to be installed indoors or in a water resistant plastic distributor You can charge the device by using the included power supply for charging from the 230 V AC socket a different power supply of an output of 11 30 V DC or AC of at least 1 A See Fig 8 for where to ...

Page 10: ... 0 35 mm2 Cu into the O1A 01B terminals of the GSM key and START terminals of your gate drive Use the power supply terminal last The device will start working within about one minute Now the GSM Key is ready to be setup in administration ...

Page 11: ...mobile phone can be done without any restrictions from any place ADMINISTRATION BY WEB INTERFACE p 19 It is possible to manage GSM Key PROFI 3 via the web interface The device is connected to a PC using the Ethernet cable Additionally it is possible to connect GSM Key PROFI 3 to the already existing computer network where it will be assigned an IP address or there s also an option of a remote conf...

Page 12: ...ed users When administering via a mobile phone please follow the shown SMS format exact text of orders empty spaces etc In order to send one or more orders in one SMS divide them by a semi colon In order to make the administration as easy as possible we recommend using the GSM key app for Android and iOS which you can download free of charge from Google Play and AppStore ADMINISTRATION OF USERS Ac...

Page 13: ...ting mode ST OUTLateEval number ST OUTLateEval 0 0 Continual evaluation 1 Late evaluation 3 Setting operating mode with confirmation SC OUTLateEval number SC OUTLateEval 0 0 Continual evaluation 1 Late evaluation 4 Checking number of rings GT OUT 1 2 3 4 ImpulseRings GT OUT1ImpulseRings Number of rings 5 Setting number of rings ST OUT 1 2 3 4 ImpulseRings numbrt ST OUT1ImpulseRings 1 Number of rin...

Page 14: ...SC OUT1ImpulseLength 1 Whole number in sec 13 Checking feedback action GT IN 1 2 3 4 Action GT IN1Action 0 send SMS 1 call 2 call and send SMS 14 Setting feedback action ST IN 1 2 3 4 Action number ST IN1Action 0 0 send SMS 1 call 2 call and send SMS 15 Setting feedback action with confirmation SC IN 1 2 3 4 Action number SC IN1Action 0 0 send SMS 1 call 2 call and send SMS 16 Checking relevant gr...

Page 15: ...ctivation condition at start of device GT IN 1 2 3 4 TriggerStart GT IN1TriggerStart 0 OFF 1 connected 2 disconnected 3 any state 25 Setting activation condition at start of device ST IN 1 2 3 4 TriggerStart nu mber ST IN1TriggerStart 1 0 OFF 1 connected 2 disconnected 3 any state 26 Setting activation condition at start of device with confirmation SC IN 1 2 3 4 TriggerStart nu mber SC IN1TriggerS...

Page 16: ...c 33 Checking disconnection delay time GT IN 1 2 3 4 ReleaseTime GT IN1ReleaseTime Whole number in sec 34 Setting disconnection delay time ST IN 1 2 3 4 ReleaseTime nu mber ST IN1ReleaseTime 2 Whole number in sec 35 Setting disconnection delay time with confirmation SC IN 1 2 3 4 ReleaseTime nu mber SC IN1ReleaseTime 2 Whole number in sec ADMINISTRATION OF OPERATING PARAMETERS Action SMS Template ...

Page 17: ...PN GT APN GT APN Name of APN 3 Checking IP GT IP GT IP IP address LAN and GPRS EDGE 4 Setting FUP limit ST FUP number ST FUP 0 0 OFF 1 ON 5 Setting FUP limit with confirmation SC FUP number SC FUP 0 0 OFF 1 ON 6 Checking FUP state GT FUP GT FUP 0 OFF 1 ON Instead of 1 2 3 4 in the order enter number of the requested input Instead 0 1 in the order enter number of the requested output ...

Page 18: ... Description 1 Setting output status ST OUT 1 2 3 4 number ST OUT1 1 0 disconnect 1 connect 2 Checking input status binary GT IN 1 2 3 4 GT IN1 0 disconnected 1 connected 3 Checking input status text GT IN 1 2 3 4 T GT IN1T Text message 4 Checking SMS text GT IN 1 2 3 4 SMS 0 1 GT IN1SMS1 Pre set text 5 Setting SMS text ST IN 1 2 3 4 SMS 0 1 number ST IN1SMS1 open Required text without empty space...

Page 19: ...the address bar in your internet browser Default username is administrator the password is blank SAVING CONFIGURATION CHANGES Any configuration change of the key needs to be saved This can be done by clicking the icon of a floppy disk at the bottom part of the window The current logged in user will be automatically signed out affter 10 minutes of inactivity DELETING CONFIGURATION CHANGES Deleting ...

Page 20: ...leave the password blank We strongly recommend to set your own password after You can change the language settings in the login screen of the web interface This change applies only for the one time login The default language of the web interface can be changed in Settings tab Web interface icon description ...

Page 21: ...mmunication bookmark status is unknow GSM registration Status of SIM card registration in GSM network GSM signal strength Actual value of signal strength GSM signal strength per hour min average max History of signal strength values per hour GSM signal strength per day min average max History of signal strength values per day GSM signal strength per month min average max History of signal strength...

Page 22: ...e local network and remote access can be setup in the Communication tab Any change of parameters needs to be saved by using the floppy disk icon in the bottom part of the screen and then the modem has to be restarted using the red icon with an arrow in it Modem restart is done in 5s LAN Parameters for connection via Ethernet cable Name Meaning Hostname Name the key used to designate the device as ...

Page 23: ...blank APN APN as instructed by the operator Account start The starting day of the month when the data connection is being charged Data limit Set the FUP data limit If the value of 0 is specified the data limit is unlimited SETTING General parameters are specified in the Setting tab Any change of parameters needs to be saved by using the floppy disk icon in the bottom part of the screen Administrat...

Page 24: ...Time Set whether it is daylight saving time Time Manually set date and time Main settings Main parameters settings of the GSM Key Name Meaning Default language Setting default language for web interface Max SMS Retry Number of try to send SMS Call HangUp Rings The setting that determinates how many rings will be made before the call will be declined SMS on Power Up In case of a power outage the SM...

Page 25: ...tion sets the activation condition valid during the GSM key run After turning on the device it checks the input value and performs the action if the condition is met Options are Off Rising Edge Falling Edge Any Edge Attack time This option sets the activation condition valid during the GSM key run Specifying the time interval for which the input must remain closed in order for the activation condi...

Page 26: ...ut evaluation settings Name Meaning Elevation Set output elevation types What are the different modes of operation In Continuous Evaluation mode you can open the first or both gates with one call without interrupting it In Late Evaluation Mode you can open the first or second gate At least two calls are required to the GSM Key to open both gates The factory setting is the Continuous Evaluation mod...

Page 27: ...arameters are changed the administrator needs to press the icon again to add the filled out user or the icon to delete it Added users need to be saved by using the floppy disk icon at the bottom part of the screen User database back up and its restoration is done using the icons Export to CSV and Import to CSV To separate items use In case of an error in the data content the file will be refused N...

Page 28: ...UPS In the Groups tab are groups into which users can be added There are three basic groups in the GSM Key that are impossible to remove Name Meaning Group User group name When you add a new group can use only uppercase and lowercase letters Removing the group in which the users are assigned will move to the Guest group Rights Rights assigned to individual groups None The group can only activate t...

Page 29: ...ace is recorded in the Event log tab Only part of the event log is shown in the window Using the first icon Download history the file containing all activity will be downloaded and using the Download events icon will download the activity of the interface only The maximum number of lines is 4000 for history and 2000 for events ...

Page 30: ...ssing the folder icon you select a new version of the firmware and by pressing the floppy disk icon you start the update After the update is finished the restart will be done automatically Updates are publicized on www gsmklic cz LOG OUT The lock icon is used to log out from the web interface ...

Page 31: ... O2 O3 O4 G S PWR connector for power supplykonektor k připojení napájecího zdroje NET interface for connection to pc or active component RST the button for device reset BACK PANEL SIM plug in SIM card reader ANT connector FME m for connecting the GSM antena O4A O1A output connectors I4 I1 input connectors COM signal ground ...

Page 32: ...ONS ABOUT THE DEVICE STATUS On the front panel are situated 8 LED diodes that inform about the device status LED Meaning I1 input 1 Off Contacts I1 and GND are 0 7 V AC DC On Contacts I1 and GND have a voltage of 15 40 V AC DC I2 input 2 Off Contacts I2 and GND are 0 7 V AC DC On Contacts I2 and GND have a voltage of 15 40 V AC DC I3 input 3 Off Contacts I3 and GND are 0 7 V AC DC On Contacts I3 a...

Page 33: ... 3 Off O3A and O3B contacts disconnected On contacts O3A and O3B are connected O4 output 4 Off O4A and O4B contacts disconnected On contacts O4A and O4B are connected G GSM signal Constantly lit malfunction Blinking communication with GSM network SWITCHING INPUTS At the bottom of the GSM key there is a switch that switches the active passive input type DI Meaning A Active mode switches to internal...

Page 34: ...vice Holding the reset button after connecting the power supply for 10s Clear Settings and Communication 5Hz flicker 30s Erase entire memory flicker at 0 3Hz I O VSTUP VÝSTUP Pin Number Signal Mark Description 1 O4B Relay output 4 max 30 V 1 A 2 O4A Relay output 4 max 30 V 1 A 3 O3B Relay output 3 max 30 V 1 A 4 O3A Relay output 3 max 30 V 1 A 5 O2B Relay output 2 max 30 V 1 A 6 O2A Relay output 2...

Page 35: ...C 10 I3 Optically isolated input 3 LOG 0 0 7 V LOG 1 15 40 V DC 11 I2 Optically isolated input 2 LOG 0 0 7 V LOG 1 15 40 V DC 12 I1 Optically isolated input 1 LOG 0 0 7 V LOG 1 15 40 V DC 13 COM Signal ground ANT The radio frequency interface marked ANT is used to connect the GSM 900 1800 dual band antenna with the FME f connector ...

Page 36: ...tly connected to the PC it is necessary to set the desired address range on the network card of the computer and the key will then be available at 192 168 0 22 Launch the START SETTINGS and then select Network Internet In the left part of the window click Change Adapter Options ...

Page 37: ... select the Additional Options using the Properties button On this tab you need to set IP address from the range Select Use the following IP address and set these parameters IP Address 192 168 0 1 Subnet mask 255 255 255 0 Then save the settings Now the GSM Key PROFI3 is ready for configuration In the browser type 192 168 0 22 or gsmkey into the address bar ...

Page 38: ...into the upper opening which is situated above the cable locks Then by applying pressure on the hook downwards the locks will open enough for the stripped cable to be put in In case of losing the hook it is possible to also use flat 2mm screwdriver which is put in the upper opening The lock will open by applying slight pressure inside into the opening In case of inadequate opening the screwdriver ...

Page 39: ... isolated inputs for sensor connection Ethernet Configuration Interface Temperature range working 200 C to 550 C Storage temperature range 400 C to 850 C Power voltage 10 30 V AC DC Consumption 0 4 W 0 42 W reception transmission Antenna connector FME m 50 Ohm Dimensions 89 x 52 x 58 mm Mounting DIN rail 35 mm Weight 160 g Josefa Šavla 1271 12 709 00 Ostrava Mariánské Hory 420 556 621 000 www gsmk...

Reviews: