- 4 -
When system is frozen, please press the reset button and keep it depressed for 5 seconds,
+
direction to adjust the aperture becomes large, to — (counterclockwise) direction to adjust the
aperture becomes small. The adjustment needs 2-3 seconds to take effective, so please wait for
aperture stable until next adjustment.
RESET
after the power light is blinking, then release the reset button, the system will finish rebooting
procedure in one minute. When the power light is on; the device is booted up successfully.
Power Lighting
When power lighting on means device boots up successfully; power lighting off means there is
no power input. When power lighting blinking means device operation system is being loaded
or hardware resets.
Exterior View
Power Connector
Connect to 12V DC/24V AC power adapter.
Ethernet
Connect to Ethernet network.
Alarm In/Out
To connect external alarm I/O devices, please refer to below for Alarm I/O pin definition.
GND
Sensor IN
ALR N.O
ALR COM
GND: ground wire.
Sensor IN: connect to alarm in device.
ALR N.O: connect to N.O(normal open) alarm out device.
ALR COM: connect point that corresponds to alarm in.