10
2.6.
Power supply
The Easyshrink
®
device is meant to be supplied with power according to these
specifications:
AC PE/ 16A/ 50-60 Hz.
A 3,5 meter cable is supplied.
Please install the appropriate male and female plugs to connect the device to your electrical network and make sure the proper
tension is delivered between each pin.
Note:
A transformer for USA or Canadian voltages is available
as an optional accessory. Please contact your Seco
representative.
Name of
the pin
Designation
of the pin
Colour of the
wire
L1
Phase L1
brown
L2
Phase L2
black or grey
L3
Phase L3
black
PE
Ground
green & yellow
Tension in V
230
230
230
400
400
400
L1 → L2
L1 → L3
L2 → L3
Measure between the
pins
PE → L1
PE → L2
PE → L3