DOOR S
EN
S
(+
) (-)
12~
24
VA
C/
VD
C
EG IN
OU
TP
UT
1
N.
C.
C
OM
N
.O
.
1 2 3 4 5 6 7 8 9 1011 12 13 14 15 16
FULLAUTO
BACKLIT
KEY ALARM
K or A
Backlit
jumper
K or A
jumper
Connection terminals
Connection wires
8
ENFORCER Access Control Keypad with Proximity Card Reader
SECO-LARM U.S.A., Inc.
Connection Wires
Wire Color
Function
Description
1
Red
Tamper N.C.
Tamper switch output, N.C. contact, max. 50mA@24VDC. Connect to the
N.C. 24-hour protection zone of an alarm if needed.
2
Black
Tamper N.C.
3
Grey
Green LED (-)
Connect to a device to trigger the green LED.
4
Green
Green LED (+)
5
Light Blue
Red LED (-)
Connect to a device to trigger the red LED.
6
Yellow
Red LED (+)
7
White
Ground (-)
Common ground output. Common with wire 15.
8
Pink
K or A Output
Transistor ground output, max. 100mA@24VDC. See “K or A” jumper
information below for programming details.
9
White/Brown
Output 2 COM
NO/NC/COM, relay output, max. 1A@30VDC
10
Blue
Output 2 N.O.
11
Purple
Output 2 N.C.
12
White/Red
Output 3
Transistor ground output, max. 100mA@24VDC
13
Orange
Output 1 Inhibit
Output #1 inhibitor. N.O. input, connect to Interlock Control of second
keypad if needed so that if one keypad is used to open a door, the other is
temporarily disabled.
14
Brown
Interlock Control
Interlock Control. N.O. input, connect to Output #1 Inhibit of second
keypad if needed so that if one keypad is used to open a door, the other is
temporarily disabled.
15
Light Green
Ground (-)
Common ground output. Common with wire 7.
16
White/Orange Duress Output
Transistor ground output, max. 100mA@24VDC. Switches to ground (-) to
trigger a silent alarm or other device when the user enters a duress code.
Connection Terminals
Terminal
Description
Output 1 N.C.
NO/NC/COM, relay output,
max. 1A@30VDC
Output 1 COM
Output 1 N.O.
Egress Input
N.O. Pushbutton contact to ground. Press
button to activate output #1
12~24 VAC/VDC Connect to a 12~24 VAC/VDC power supply.
Observe polarity.
Door Sensor
Connect to an optional N.C. sensor such as a
magnetic contact to monitor if a door is open
or closed. Connect to ground (-) if not used.
Wiring Diagram:
Jumper Settings
Jumper
Position
Description
Backlit
Full
Dim backlit during standby. Full backlit for 10 seconds after any button press.
Auto
No backlit during standby. Full backlit for 10 seconds after any button press.
K or A
K
Switches to ground (-) for 10 seconds after any button pressed.
A
Switches to ground (-) when alarm occurs.