5
ENFORCER Access Control Keypad with Proximity Card Reader
SECO-LARM U.S.A., Inc.
Features:
Specifications:
Operating voltage
12~24 VAC/VDC
Current draw
(at 12VDC)
Standby
66mA
Keypress
93mA
Output 1 active
99mA
Output 1 & 2 active
126mA
Output 1, 2, & 3 active
127mA
Total max current draw
160mA
Outputs
#1 – Form C
1A@30VDC
#2 – Form C
1A@30VDC
#3 – Transistor ground
100mA@24VDC
K or A
100mA@24VDC
Duress
100mA@24VDC
Interlock
100mA@24VDC
Tamper
50mA@24VDC
Inputs
Egress
N.O. Ground
Door sensor
N.C. Ground
Door inhibit
N.O. Ground
Proximity reader frequency
125kHz (EM125)
Proximity reader sensing distance
1
1/2
” (38mm)
Operating temperature
-4°~158° F (-20°~70° C)
Operating humidity
5~95% Non-condensing
Dimensions (including back box)
4
5/8
”x2
7/8
”x1
1/2
” (117x73x38 mm)
Weight
6-oz (170g)
•
Built-in proximity card reader
•
12~24 VAC/VDC Auto-adjusting operation
•
Up to 1,000 possible user codes (000~999)
and/or proximity cards programmable for
output #1, 100 (001~100) for output #2, and
100 (001~100) for output #3
•
Up to 50 (01~50) possible temporary visitor codes,
which can be programmed for one-time or limited-
time use (1~99 hours)
•
Output #1: Form C relay, 1A@30VDC max.
•
Output #2: Form C relay, 1A@30VDC max.
•
Output #3: Transistor ground, 100mA@24VDC
•
Outputs #1, #2, and #3 can be programmed to
activate for up to 99,999 seconds (nearly 28 hours)
•
Tamper output: N.C. Dry contact, 50mA@24VDC
max.
•
Keypad illuminates when a button is pressed;
backlight can be programmed for FULL or AUTO in
standby mode
•
Mounts to a standard single-gang back box
(surface-mount back box included)
•
All features are programmed directly from the
keypad: No need for an external programmer
•
EEPROM Memory protects programmed
information in case of power loss
•
Up to 50 (01~50) duress codes for output #1,
10 (01~09) for output #2, and 10 (01~09) for
output #3
•
Duress code signals a silent alarm if an authorized
user is forced to open the door under duress
•
Egress input lets users exit the premises without
keying in the code
•
Door sensor input for anti-tailgating operation
•
Interlocking input for connecting to a second
keypad
•
Keypad active or alarm output selectable via
jumper