ENFORCER Heavy-Duty Outdoor Stand-Alone Keypad
SECO-LARM U.S.A., Inc 5
SECO-LARM U.S.A., Inc.
33
5
Installation:
1.
Unlock the keylock mounted on the face of the keypad
with one of the included keys.
2.
Open the faceplate of the keypad. The hinge will allow
the faceplate to open to a 90
°
angle.
3.
Remove the 1” wiring hole cover from back of keypad.
4.
Run wires into the keypad using the 1” wiring hole on
the back of the enclosure.
5.
Using the wiring diagram on pg. 4, wire the keypad
according to the specific application.
6.
Place the included gasket between the keypad and
mounting surface.
7.
If attaching the keypad to a mounting plate such as a
gooseneck stand, use the 4 mounting plate holes
located on the back of the keypad.
These holes are
used to mount the
keypad to a
gooseneck stand.
Wiring – Connecting to a Lock Device and Alarm Arm/Disarm:
1
Connect a IN4004 diode (not included) as close as possible and in parallel with an electric strike.
This absorbs possible electromagnetic interference to prevent operation of the strike from
damaging the keypad. Do not connect a diode when using electromagnetic locks.
2
Please consult the alarm control panel’s manual for more information.
Cathode
To alarm control panel
(24-hour N.C. zone)
2
To alarm control panel
(Alarm arm/disarm control)
2
IN4004
Diode
Electric strike
Egress
button
EARTH
GROUND
12~24
VAC/VDC
REED
OU
TPU
T 1
OU
TPU
T 2
COM (-)
EG IN
N.O.
COM
N.C.
N.O.
COM
N.C.
N.C.
Tamper
12~24
VAC/VDC
Power Supply
Magnetic
contact