When the reed jumper is in place (default), the door sensor input is bypassed.  
To enable the door sensor input, place the reed jumper on one pin only. 

 

When the door sensor input is enabled, connect the COM (-) terminal 
and REED terminal to a N.C. contact.  The keypad will deactivate 
output #1 whenever the contact is opened and closed, working as an 
anti-tailgating feature. 

 

The green LED will flash rapidly whenever the N.C. contact is open  
and the relay is inactive. 

Important Notes: 

1.

 

Always disconnect power before servicing the keypad. 

2.

 

The keypad must be properly grounded. Use a minimum 22AWG (18AWG is best) wire to 
ground the circuit board’s earth terminal. Failure to do so may damage the keypad. 

3.

 

All wiring and programming should be done by a professional installer to reduce the risk of  
improper installation. 

4.

 

Operating instructions are located on page 12 of this manual. Be sure to store this manual 
in a safe place for future reference. 

 

Wiring Diagram: 

Earth ground terminal:

  Connect a continuous wire from the Earth Ground terminal to a grounding point to avoid 

damage from static discharge.  

If using an AC adapter for power input, do not connect the AC adapter output to 

Earth Ground. 

Reed Jumper: 

Earth ground 

Power 12~24 VAC / VDC 

(non-polarity)

 

Reed / door sensing input (N.C.) 

Push button / egress input (N.O.) 

Relay 1 

12A@14VDC, Form C, NO/NC/COM 

Relay 2 

12A@14VDC, Form C, NO/NC/COM

 

N.C. Tamper output (3A@125/250VAC) 

12~24 

VAC/VDC 

REED 
COM (-) 
EG IN 

OU
TPU

T 1

 OU
TPU

T 2

 

N.O. 
COM 
N.C. 
N.O. 
COM 
N.C. 

N.C. 

Tamper 

EARTH  

GROUND 

Door Sensor 

Bypassed 

(Default) 

 

Door Sensor 

Enabled 

 

IF USING THE SK-3523-SDQ WITH A MECHANICALLY OPERATED DOOR OR 

GATE, MOUNT THE KEYPAD AT LEAST 10 FEET FROM THE DOOR OR GATE TO 

PREVENT USERS FROM BEING CRUSHED OR PINNED. FAILURE TO DO SO MAY 

RESULT IN SERIOUS INJURY OR DEATH. 

Summary of Contents for ENFORCER SK-3523-SDQ

Page 1: ...r have a round green Q sticker represent RoHs compliant products Manual SK 3523 SDQ Heavy Duty Outdoor Stand Alone Keypad Also available from SECO LARM SK 1123 SQ SK 1123 FQ SK 1011 SQ SK 1131 SQ SK 2...

Page 2: ...VDC Door sensing input allows for anti tailgating operation Overhead LEDs and programmable backlit keys Each relay output can be set from 1 99 seconds or toggle Wrong code lockout After 3 wrong codes...

Page 3: ...cess code valid entry 2 Short beeps Enter exit programming mode 3 Short beeps Incorrect user code 3 sec after code entered invalid input programming mode 15 Long beeps All Output 1 or Output 2 codes c...

Page 4: ...installer to reduce the risk of improper installation 4 Operating instructions are located on page 12 of this manual Be sure to store this manual in a safe place for future reference Wiring Diagram E...

Page 5: ...eck stand use the 4 mounting plate holes located on the back of the keypad These holes are used to mount the keypad to a gooseneck stand Wiring Connecting to a Lock Device and Alarm Arm Disarm 1 Conne...

Page 6: ...ENFORCER Heavy Duty Outdoor Stand Alone Keypad 6 SECO LARM U S A Inc...

Page 7: ...ENFORCER Heavy Duty Outdoor Stand Alone Keypad SECO LARM U S A Inc 7...

Page 8: ...m the earth terminal to earth ground For more details please see page 4 Earth Ground Terminal 2 Run two wires from the gate operator s power output terminals to the SK 3523 SDQ s power terminals 3 Run...

Page 9: ...cking device For N O locking devices Connect output 2 in series with the locking device Wiring Door Hold Open Code Tamper N C Door Sensing Wiring Auxiliary Accessories Relay Output 2 Example to shunt...

Page 10: ...press until the yellow LED is flashing steadily then re enter programming mode 0 Step 1 Step 2 Step 3 Enter a new master code 0 0 X X X X The yellow LED will turn solid confirming the new master code...

Page 11: ...all output codes for the selected output Enter Step 1 Keypad backlighting is always ON Keypad backlighting is ON for 10 seconds after a key press Enter Step 2 Step 3 Return to programming mode by ent...

Page 12: ...or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and...

Reviews: