ENFORCER Heavy-Duty Outdoor Stand-Alone Keypad
12
SECO-LARM U.S.A., Inc.
Troubleshooting:
Keypad programming option won’t work
Make sure the keypad is in programming mode. Enter
programming mode by entering the master code twice.
Make sure to press before every programming option.
Press until you have exited programming mode. Try
entering programming mode again.
Keypresses and programming options won’t register
The keypad may be in lockout mode. Wait 55 seconds,
or disconnect and reconnect the power
A device wired to the keypad won’t activate
Check the wiring diagram on page 4.
#
NOTICE:
The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice.
SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2013 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of
SECO-LARM.
WARRANTY
This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of two (2) years from
the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal
usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than
defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event
shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.
Operation and Programming Quick Reference Guide:
mi-SK-3523-SDQ_1301.docx
PITGW1
SECO-LARM
®
U.S.A., Inc
.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
E-mail: [email protected]
Operation Function
Action
Enter an Output #1 user code
Directly enter on the keypad
Enter an Output #2 user code
Directly enter on the keypad
Enter programming mode
Enter the master code twice
Exit programming mode
Press repeatedly until the yellow LED is flashing steadily.
Operation Function
Step 1
Step 2
Step 3
Programming a new master
code
Press
Enter
000
Enter the new master code
Programming an Output #1
user code
Press
Enter an Output #1
ID number
001~200
Enter an Output #1 user code
Programming an Output #2
user code
Press
Enter an Output #2
ID number
201~210
Enter an Output #2 user code
Deleting a user code
Press
Enter an ID number
001~210
Enter
0000 or 00000
Output #1 timer
Press
Enter
300
Enter:
00
for toggle
01
to
99
for # seconds
output will activate
Output #2 timer
Press
Enter
400
Enter:
00
for toggle
01
to
99
for # seconds
output will activate
Delete all Output #1 Users
Press
Enter
888
Enter
00
Delete all Output #2 Users
Press
Enter
999
Enter
00
Note
: For complete programming instructions, please see page 10,
Programming Instructions.
The following functions are performed
after
entering Programming Mode.
#