Specifications: 

 

E-941SA-600PQ 

E-941DA-600Q 

E-941DA-600PQ 

Door Type 

Single Door 

Double Door 

Magnet Size 

9

7

/

8

”x1”x1

11

/

16

” 

(250x25.5x43 mm) 

19

3

/

4

”x1”x1

11

/

16

” 

(500x25.5x43 mm) 

Armature Size 

7

1

/

4

”x

1

/

2

”x1

1

/

2

” 

(185x12x38 mm) 

7

1

/

4

”x

1

/

2

”x1

1

/

2

” x 2 

(185x12x38 mm) x 2 

Status Sensor 

Relay, 1A@12VDC 

n/a 

Relay, 1A@12VDC

1

 

Status LED (2-color) 

Green (locked), 

Red (unlocked) 

n/a 

Green (locked)

1

Red (unlocked)

1

 

Weight 

4-lb 6-oz (2.0kg) 

8-lb 13-oz (4.0kg) 

Power 

12VDC/24VDC 

Current Drain 

430mA@12VDC

1

 / 230mA@24VDC

1

 

Voltage Tolerance 

±10% 

Holding Force 

600-lb (272kg)

1

 

Housing 

Aluminum 

Temperature 

14°~131° F (-10°~°55 C) 

1

On each side, for double door models  

 

Installation: 

A.

 

Drill holes for the mounting plate and armature plate (see fig. 1 and 2) by doing the following:

 

1.

 

Fold the mounting template along the dotted line. 

2.

 

Close the door. Find a mounting location on the door frame near the upper free-moving corner of 
the door, as close to the corner of the door frame as possible. 

3.

 

Place the template against the door and frame. 

4.

 

Drill two holes in the door frame and three holes in the door as indicated on the template. 

NOTE:

 A filler plate or an L-bracket or Z-bracket (optional) may be required for the electromagnet, depending on the door 

frame. See fig. 1. 

B.

 

Mount the armature plate on the door using at least two steel washers and one rubber washer (fig. 2):

 

NOTE:

 Actual installation varies according to door style. 

1.

 

Put one rubber washer between two steel washers, and place them over the armature screw 
between the armature plate and the door. This will allow the armature plate to pivot slightly 
around the armature screw in order to compensate for door misalignment.  

2.

 

Tighten the sexnut bolt enough so the armature plate can withstand the force of someone 
attempting to break down the door while the electromagnet is engaged. 

3.

 

Do not tighten the armature plate against the door. The plate must be able to pivot around the 
armature screw. 

4.

 

Make sure the anti-spin guides are in the two guidepin holes. 

C.

 

Screw the mounting plate onto the door frame or optional bracket:

 

1.

 

Screw the two short self-tapping screws in the slotted holes of the mounting plate and adjust the 
position of the mounting plate so that it and the armature plate are at a 90-degree angle. 

2.

 

Once the position is correct, use the long self-tapping screws to permanently mount the bracket. 

3.

 

Remove the two short screws. 

D.

 

Drill the cable access hole.

 

E.

 

Mount the electromagnet on the door frame (fig. 1):

 

1.

 

Use the Allen wrench to screw the socket-head mounting screws through the bottom of the 
electromagnet into the mounting bracket. 

ENFORCER

 

®

 600-lb Electromagnetic Lock 

 

 

 

SECO-LARM

 

®

 

U.S.A., Inc 

F.

 

 Connect the power leads (fig. 3)

 

1.

 

Open the electromagnet and run two power leads from the power supply through the cable 
access hole into the electromagnet. 

2.

 

Connect the power leads to the terminal block and close the electromagnet. 

3.

 

Test the unit. 

G.

 

Insert the tamper caps into the mounting screw access holes.

 

NOTE:

 This should be the last step, as once the tamper caps are in place, they are difficult to remove. 

 

Diagrams: 

Figure 1 

 

 

Figure 2 

 

 

 

 

Relay 

Voltage 

Selection 

Jumpers 

E-941SA-600PQ 

Control 

Device 

Power 

Supply 

Status LED* 

*Status LED:

 

Indicates whether 
the magnetic lock 
is locked or 
unlocked. 

Green — Locked  
Red — Unlocked 
Off — No power  

Status Sensor Output  
SPDT rated 1A@12VDC 

Voltage Selection 

24VDC 

Position a jumper over 
the two middle pins for 
24VDC operation. 

Status Sensor Output: 

Monitors whether the protected door 
is open or closed. 
N.C. — Door is open, red LED on. 
N.O. — Door closed, green LED on. 
Relay — 1A@12VDC. 

*E-941SA/DA-600PQ models only 

Figure 3 

Status Sensor Output: 
Connect to an alarm panel or 
other monitoring device 

 

12VDC 

Magnet set for 12VDC 
operation as supplied 
from factory. 

*  Note: may require more than 