600-lb Electromagnetic Lock
2
SECO-LARM
®
U.S.A., Inc
Specifications:
E-941SA-600PQ
E-941DA-600Q
E-941DA-600PQ
Door Type
Single Door
Double Door
Magnet Size
9
7
/
8
”x1”x1
11
/
16
”
(250x25.5x43 mm)
19
3
/
4
”x1”x1
11
/
16
”
(500x25.5x43 mm)
Armature Size
7
1
/
4
”x
1
/
2
”x1
1
/
2
”
(185x12x38 mm)
7
1
/
4
”x
1
/
2
”x1
1
/
2
” x 2
(185x12x38 mm) x 2
Status Sensor
Relay, 1A@12VDC
n/a
Relay, 1A@12VDC
1
Status LED (2-color)
Green (locked),
Red (unlocked)
n/a
Green (locked)
1
,
Red (unlocked)
1
Weight
4-lb 6-oz (2.0kg)
8-lb 13-oz (4.0kg)
Power
12VDC/24VDC
Current Drain
430mA@12VDC
1
/ 230mA@24VDC
1
Voltage Tolerance
±10%
Holding Force
600-lb (272kg)
1
Housing
Aluminum
Temperature
14°~131° F (-10°~°55 C)
1
On each side, for double door models
Installation:
A.
Drill holes for the mounting plate and armature plate (see fig. 1 and 2) by doing the following:
1.
Fold the mounting template along the dotted line.
2.
Close the door. Find a mounting location on the door frame near the upper free-moving corner of
the door, as close to the corner of the door frame as possible.
3.
Place the template against the door and frame.
4.
Drill two holes in the door frame and three holes in the door as indicated on the template.
NOTE:
A filler plate or an L-bracket or Z-bracket (optional) may be required for the electromagnet, depending on the door
frame. See fig. 1.
B.
Mount the armature plate on the door using at least two steel washers and one rubber washer (fig. 2):
NOTE:
Actual installation varies according to door style.
1.
Put one rubber washer between two steel washers, and place them over the armature screw
between the armature plate and the door. This will allow the armature plate to pivot slightly
around the armature screw in order to compensate for door misalignment.
2.
Tighten the sexnut bolt enough so the armature plate can withstand the force of someone
attempting to break down the door while the electromagnet is engaged.
3.
Do not tighten the armature plate against the door. The plate must be able to pivot around the
armature screw.
4.
Make sure the anti-spin guides are in the two guidepin holes.
C.
Screw the mounting plate onto the door frame or optional bracket:
1.
Screw the two short self-tapping screws in the slotted holes of the mounting plate and adjust the
position of the mounting plate so that it and the armature plate are at a 90-degree angle.
2.
Once the position is correct, use the long self-tapping screws to permanently mount the bracket.
3.
Remove the two short screws.
D.
Drill the cable access hole.
E.
Mount the electromagnet on the door frame (fig. 1):
1.
Use the Allen wrench to screw the socket-head mounting screws through the bottom of the
electromagnet into the mounting bracket.
ENFORCER
®
600-lb Electromagnetic Lock
SECO-LARM
®
U.S.A., Inc
3
F.
Connect the power leads (fig. 3)
1.
Open the electromagnet and run two power leads from the power supply through the cable
access hole into the electromagnet.
2.
Connect the power leads to the terminal block and close the electromagnet.
3.
Test the unit.
G.
Insert the tamper caps into the mounting screw access holes.
NOTE:
This should be the last step, as once the tamper caps are in place, they are difficult to remove.
Diagrams:
Figure 1
Figure 2
Relay
Voltage
Selection
Jumpers
E-941SA-600PQ
Control
Device
Power
Supply
Status LED*
*Status LED:
Indicates whether
the magnetic lock
is locked or
unlocked.
Green — Locked
Red — Unlocked
Off — No power
Status Sensor Output
SPDT rated 1A@12VDC
Voltage Selection
24VDC
Position a jumper over
the two middle pins for
24VDC operation.
Status Sensor Output:
Monitors whether the protected door
is open or closed.
N.C. — Door is open, red LED on.
N.O. — Door closed, green LED on.
Relay — 1A@12VDC.
*E-941SA/DA-600PQ models only
Figure 3
Status Sensor Output:
Connect to an alarm panel or
other monitoring device
12VDC
Magnet set for 12VDC
operation as supplied
from factory.
* Note: may require more than
one filler plate.