background image

SECO-LARM 

 Double-Door Electromagnetic Locks 

SECO-LARM U.S.A., Inc. 

Door Frame 

Door 

Door 

Door Frame 

Door  

Template 

Door Frame 

 

Ideal 

Mounting 

Location 

Ideal 

Mounting 

Location 

3.

 

Place the template 
against the door and 
frame. Mark where 
the holes are to be 
drilled. 

2.

 

Close the doors. Find a mounting location on the 
center of the door frame, directly above where 
both doors meet when closed.  

5.

 

Use a hammer to 
lightly tap the guide 
pins into the guide pin 
holes on the armature 
plates. 
 
 

 

Drill two 

5

/

16

" (8mm) dia. holes through 

the armature-plate side of the doors for 
the armature screws. Then drill two 

5

/

8

"

 

(16mm) dia. holes for sexnut screws on 
the opposite side of the doors. 

5

/

8

" (16mm) 

5

/

16

" (8mm) 

Hollow Metal Door 

Reinforced Door 

1

/

4

" (6.8mm) for M8x1.25 thread 

Drill two 

1

/

4

" (6.8mm) dia. 

and 1" (25mm) deep 
hole, tap for M8x1.25

 

thread on each door. 

Solid Core

 

Drill two 

5

/

16

" (8mm) dia. holes on the 

doors for the armature screws, and drill 
two 

1

/

2

" (12.7mm) dia. and 1" (25mm)

 

deep hole for the sexnut screws.

 

 

1

/

2

" (12.7mm) 

5

/

16

" (8mm) 

Installation 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

4.

 

Drill four holes in the frame and six holes in 
the door as shown on the template. 

1.

 

Fold the mounting template along the dotted 
line to form a 90-degree angle.

 

 

6.

  Depending on the type of door being protected, drill holes according to the diagrams below: 

Summary of Contents for E-941DA-600Q

Page 1: ...le mounting bracket Complete mounting hardware for typical installations L bracket and Z brackets available for easy mounting Detachable faceplate 12 24VDC selectable NOTES UL294 Indoor use The power...

Page 2: ...Current draw 12VDC 500mA 12VDC per door 1A total 24VDC 250mA 24VDC per door 500mA total Bond sensor relay 3A 12VDC Dimensions Magnet 1911 16 x11 16 x15 8 500x26x40 mm 21 x15 8 x25 8 536x42x67 mm Arma...

Page 3: ...ual will make installation much easier 2 The electromagnetic locks are designed for indoor use ONLY 3 The most suitable mounting location for the electromagnetic locks may require the use of additiona...

Page 4: ...ate side of the doors for the armature screws Then drill two 5 8 16mm dia holes for sexnut screws on the opposite side of the doors 5 8 16mm 5 16 8mm Hollow Metal Door Reinforced Door 1 4 6 8mm for M8...

Page 5: ...Put a rubber washer between the two metal washers and place them over the armature screw between the armature plates and the doors This allows the plates to pivot around the screw to compensate for d...

Page 6: ...4VDC Minimum Wire Gauge Wire Length 25ft 50ft 75ft 100ft 150ft 200ft 250ft 300ft 400ft 500ft 1000ft Wire Gauge 500mA 20 18 18 18 16 14 14 12 10 Wire Length 25ft 50ft 75ft 100ft 150ft 200ft 250ft 300ft...

Page 7: ...unlocking Wiring Diagram A fail safe lock unlocks when power is lost so that in case of an emergency such as a fire in the building the fail safe lock will automatically unlock allowing personnel to...

Page 8: ...ipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacem...