Troubleshooting 

Doors lock, but can easily 
be forced open   

 

Make sure the electromagnet and armature plates are properly 
aligned.  

 

Make sure the contact surfaces of the electromagnet and armature 
plates are clean and free from rust.  

 

Check the power leads with a meter, and make sure 12VDC or 
24VDC is present. 

 

Make sure the rubber washer is installed and free from damage.   

Delay in door releasing   

 

The electromagnet is fitted with a metal oxide varistor to prevent 
interference, so do not install a second diode.    

 

Ensure that the control device is connected between the power 
source and the positive terminal of the lock 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECO-LARM

 ®  

U.S.A., Inc.

 

16842 Millikan Avenue, Irvine, CA 92606 

Website: www.seco-larm.com 

Phone: (949) 261-2999  |  (800) 662-0800 

E-mail: sales

@

seco-larm.com

 

 

WARRANTY

 This SECO-LARM product is warranted against defects in material and workmanship while used in normal 

service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is 
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. 
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, 
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines 
that such equipment is not operating properly as a result of causes other than defects in material and workmanship. 
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at 
SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential 
personal or property damages of any kind to the purchaser or anyone else. 

NOTICE: 

The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves 

the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the 
property  of  SECO-LARM U.S.A., Inc.  or  their  respective  owners.  Copyright © 2021  SECO-LARM U.S.A., Inc.  All  rights 
reserved.  

California Proposition 65 Warning:

 These products may contain chemicals which are known to the State of California to 

cause cancer and birth defects or other reproductive harm. For more information, go to 

www.P65Warnings.ca.gov

 

IMPORTANT:

 Users and installers of this product are responsible for ensuring that the installation and configuration of this 

product complies with all national, state, and local laws and codes. SECO-LARM will not be held responsible for the use of 
this product in violation of any current laws or codes.  

IMPORTANT WARNING:

 Incorrect mounting which leads to exposure to rain or moisture inside the enclosure could cause 

a dangerous electric shock, damage the device, and void the warranty. Users and installers are responsible for ensuring that 
this product is properly installed and sealed.  

 

PITGW1 

 

MI_E-941DA-xxxQ_210806.docx 

 

Summary of Contents for E-941DA-600Q

Page 1: ...le mounting bracket Complete mounting hardware for typical installations L bracket and Z brackets available for easy mounting Detachable faceplate 12 24VDC selectable NOTES UL294 Indoor use The power...

Page 2: ...Current draw 12VDC 500mA 12VDC per door 1A total 24VDC 250mA 24VDC per door 500mA total Bond sensor relay 3A 12VDC Dimensions Magnet 1911 16 x11 16 x15 8 500x26x40 mm 21 x15 8 x25 8 536x42x67 mm Arma...

Page 3: ...ual will make installation much easier 2 The electromagnetic locks are designed for indoor use ONLY 3 The most suitable mounting location for the electromagnetic locks may require the use of additiona...

Page 4: ...ate side of the doors for the armature screws Then drill two 5 8 16mm dia holes for sexnut screws on the opposite side of the doors 5 8 16mm 5 16 8mm Hollow Metal Door Reinforced Door 1 4 6 8mm for M8...

Page 5: ...Put a rubber washer between the two metal washers and place them over the armature screw between the armature plates and the doors This allows the plates to pivot around the screw to compensate for d...

Page 6: ...4VDC Minimum Wire Gauge Wire Length 25ft 50ft 75ft 100ft 150ft 200ft 250ft 300ft 400ft 500ft 1000ft Wire Gauge 500mA 20 18 18 18 16 14 14 12 10 Wire Length 25ft 50ft 75ft 100ft 150ft 200ft 250ft 300ft...

Page 7: ...unlocking Wiring Diagram A fail safe lock unlocks when power is lost so that in case of an emergency such as a fire in the building the fail safe lock will automatically unlock allowing personnel to...

Page 8: ...ipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacem...

Reviews: