background image

4

User Operation

4.1  Use Card Open Door

Read valid user card once, the lock opened.

4.2  Use Card and Password Open Door

Read valid user card once, then enter 4-6 digits user’s password, press “#”, the lock opened.

4.3  Use Card or Password Open Door

Read user card once, the lock opened.

Or enter 4-6 digits user’s password, press “#”, the lock opened.

4.4  Multi-Card Open Door: the door opening mode is required to be card 
mode, the number of multi-card door opening  is set to 2-10

Read 2-10 times different valid user card(the interval should not exceed 5 seconds), the lock 

opened.

4.5  Electric Lock Switch Mode

In normal mode, the electric lock will be closed for a period of time after being opened, which is 

equal to a delay switch.

In switch mode, switch the state of electric lock once for each valid unlock operation, and keep 

the state of lock all the time.

4.6  Modify User Password

Press “*”, read user card once, enter 4-6 digits old password #, enter 4-6 digits new password 

#, repeat enter 4-6 digits new password#.

Or press “#”, enter 1-2000(ID) #, enter 4-6 digits old password #, enter 4-6 new password #, 

repeat enter 4-6 digits new password #.

Note: password users must get their ID number and initial password from administrator, for 

cardholders, modifying password must use card mode at the first time.

5. Alarm Function

6. Anti-crack Function

5.1 Anti-tamper Alarm

When turn on anti-tamper Alarm function, if the device is disassembled illegally, the built-in 

buzzer and external alarm will both alarm.

5.2 Door Status Alarm

When connect with door status switch, if the door is opened illegally, the built-in buzzer and 

external alarm will both alarm.

5.3 Anti-stress Alarm

When the door is forced to open by illegal elements:

Read anti-stress card, or enter anti-stress password #, the door opened, the external alarm will 

alarm, but built-in buzzer don’t alarm.

5.4 Cancel the Alarm

During anti-tamper and door status alarm, read valid user card or enter administrator password 

to cancel alarm, if there is no any operation, the alarm will canceled automatically beyond the 

set alarm time.

To prevent malicious cracking of the card and password, try to enter an invalid administrator 

password

user password

anti-stress password or read invalid card, and start corresponding 

operation after 10 times errors, including three levels: unlimited number of errors, 10 times 

errors locked for 10 minutes, 10 times errors alarm for 1-3 minutes.

3/8

Summary of Contents for sKey2

Page 1: ...sKey2 INSTRUCTION MANUAL...

Page 2: ...s no large area non metal card reading window 125Khz built in EM HID card reader 13 56Mhz built in Mifare CPU card reader ISO14443A Multi function including card reader standalone access control anti...

Page 3: ...ALARM 12V GND D0 D1 LED BZ PUSH 12V GND NO COM NC Stick the punch sticker on the wall drill 14mm hole for outlet and 4 6mm installation holes with expansion then insert 4 expansion rubber bungs into...

Page 4: ...s new password Note password users must get their ID number and initial password from administrator for cardholders modifying password must use card mode at the first time 5 Alarm Function 6 Anti crac...

Page 5: ...Red Flash Buzzer Short Beep Long Beep Long Beep Long Beep 3 short beep Two short beep Long beep Alarm Voice Red Flash 6 8 digits administrator password Remark Default 888888 Function Enter administra...

Page 6: ...igit card number such as 0007765567 some cards omit the front number 000 written in 7765567 and add 0 in front to input 0007765567 Adding a user password 1234 with the card at the same time this passw...

Page 7: ...rking state When the alarm is turned off it is invalid for the anti tamper anti stress and door status alarm Refers to static state operation in accordance with the normal instructions After entering...

Page 8: ...Mifare card output format is wiegand 26 37 HID card does not need to be set and automatically wiegand 26 37 output according to card format The output format should match the connected controller and...

Page 9: ...tting error Cannot open door after inputting user password Alarm under normal situation No reaction after reading card The Keypad light doesn t work Can not enter administrator setting Other Phenomeno...

Page 10: ...sKey2 complete manual...

Reviews: