![Sebury B6 Plus User Manual Download Page 34](http://html1.mh-extra.com/html/sebury/b6-plus/b6-plus_user-manual_1230011034.webp)
B6K2 Standalone Access Controller User Manual V1.0
NetDigital Security
34
5.5 Demo mode management menu summary table
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) #
Menu Parameter or operation step
Function
Default
value
03
0#
Reader mode
1
1#
Single-door mode
2#
Double-doors mode
3#
Interlock mode
9#
Demo mode
09
0000#
Restore default settings, admin password and user
information unchanged.
32
0#
Set lock to Delay mode
0
1#
Set lock to Switch mode
2#
Set the lock to Normal-open mode
34
0#
Set Open-time to 50mS
2
(1-999)#
Set Open-time from 1 to 999S
51
1,1,…,#
Decrease the brightness of the normally bright red indicator
18
2,2,…,#
Increase the brightness of the normally bright red indicator
52
0#
Key backlit is always off
1
1#
Key backlit is always on
(2-99)#
After delay 2-99 seconds, Key backlit turn to micro light
53
1,1,…,#
Decrease the brightness of the backlit
14
2,2,…,#
Increase the brightness of the backlit
55
1,1,…,#
Decrease the keypad tone
10
2,2,…,#
Increase the keypad tone
6 Precautions in use
➢
Lead line cannot be connected wrong, especially the power line, otherwise the machine may be burned or not work
properly.
➢
Because the machine internal relay is used for signal output, cannot directly drive large power load, in order to ensure the
long-term stable operation of the machine, the electric lock be not connected directly with NO, NC, COM of the machine,
but driven by an access control special power supply.
➢
When you enter the management mode or change the user PIN, you must press and hold the * key for more than two
seconds to be valid.
➢
Is for the sake of safety, the default admin initial password 888888 only support the menu 00, which forced users to
change the 6-digit admin password, or cannot access other settings.
➢
The factory default mode is the single-door mode. If you need other mode functions, you must enter the appropriate mode
to operate properly. In different modes, the management menu is also different.