2.2 Wiring
According to the selected wiring diagram, cut the lead wire to the right length and cut off the excess thread, through the wall
or in the embedded box, connect the system line with the wiring diagram. Be careful not to connect the wrong or short circuit,
otherwise it may burn the machine. After checking, power on for a short time, test if the indicator light is normal and if the
buzzer ring one time beep. Otherwise, power off immediately and recheck the wiring properly. After check again and if all is
well, install the front case of the product onto the bottom case on the wall and fix it with the anti-demolition screw as below:
The product wiring colors and functions are shown in the following table:
Color
Symbol
Functions
Light green
AC2
One port of the AC power supply
Blue
NO
Normal open port of Relay
Purple
COM
Common port of Relay
Orange
NC
Normal close port of Relay
Grey
ALARM(BELL)
Alarm (or doorbell) signal MOS drain output
Yellow
OPEN(BEEP)
Exit button input(or external control input of buzzer)
Brown
D_IN(LED_G)
Door contact input (or external control input of green LED)
Red
+12V(AC1)
Positive DC power(or another port of AC power supply)
Black
GND
Ground
Green
D0
Wiegand signal, D0 input or output(or RS232-TTL signal output: Tx)
White
D1
Wiegand signal, D1 input or output(or RS232-TTL signal input : Rx)
Pink
D_IN2(LED_R)
Door contact input of zone 2 (or external control input of red LED)
Yellow & Black
OPEN2
Exit button input of zone 2
White & Black
NO2
Normal open port of Relay 2
Green & Black
COM2
Common port of Relay 2
Red & Black
NC2
Normal close port of Relay 2