4.1.27 Set doorbell key mode

 

57. 0#, default value, the doorbell key is invalid. 
57, 1#, the doorbell key is valid, but without volume. 
57, 2#, the doorbell key is valid, with “ding dong” tone 

Note: When the doorbell key is valid, if a special doorbell decoder for our company be used with it, then the relay will connect 
after press the doorbell key, the relay will release after loosen the doorbell key.

 

If the Alarm is set to lead the doorbell signal 

output, then press the doorbell key that the output low, loosen the doorbell key output high level. The Alarm wire is internally 
connected with the drain of the NMOS tube, and the output is active low, which can drive the current below 1A. 

4.2.28

 

Set reader output format 

4.2.28.1 Set facility code 

60, (0-255)#, default value is 0, set facility code. 

Note: The key output format is multi key buffer output, the facility code will be used, See the following sections for specific 
use. 

4.1.28.2 Set D0 & D1 output format

 

61, 0#, D0 & D1 output wiegand format. 
61, 1#, D0 output RS232-TTL-HEX format. 
61, 2#, D0 output RS232-TTL-ASCII-8 format 
61, 3#, D0 output RS232-TTL-ASCII-10 format. 

Note: The wiegand format is an international protocol for access control products. But the width of pulse and interval time are 
different. Our standard: Pulse’s high level is 5V and low level is 0V. Width is 40uS,interval time is 2mS. 
RS232-TTL-HEX format refers to the standard RS232 communication protocol data output, TTL level 0-5V, the output data is 
output by the card byte HEX format. 
The output RS232-TTL-ASCII-8 format is the output data is ASCII character format, card number data is 8 bit format, and 

same as the ordinary EM card marked on the 8 bit card number, but omit the 0 in front of it. 

The output RS232-TTL-ASCII-10 format is the output data is ASCII character format, card number data is 10 bit format, and 

same as the ordinary EM card marked on the 10 bit card number, but omit the 0 in front of it. 

For example, a 3 byte number of RS232-TTL-HEX format is A83EF6, the actual output is A83EF6, the RS232-TTL-ASCII-8 
format is 168,16118, the actual output is 16816118, the RS232-TTL-ASCII-10 format is 0011026166, the actual output is 
11026166. 

4.1.28.3 Set wiegand output format for reading card

 

62, (26-66)#, default value is 26, the Wiegand output format for reading card can be set from 26-66. 

Summary of Contents for B6-EH Plus

Page 1: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 1 B6 Plus USER MANUAL V1 0...

Page 2: ...gement menu operation mode 15 3 8 User open door 15 4 Basic Functions 15 4 1 Management menu operations 15 4 1 1 Change Admin Password 15 4 1 2 Set or delete Super open password 16 4 1 3 Set admin car...

Page 3: ...l open card operation 25 4 3 Users operation 25 4 3 1 Get user card or PIN 25 4 3 2 Change user PIN 25 4 3 3 User Open door 25 4 4 Other operations 26 4 4 1 Cancel alarming 26 4 4 2 Admin Password ini...

Page 4: ...n set output format Support Card and PIN Multi cards to open the door Support Super open card and Super open password to open door Support Add card Delete card Anti duress card Authorization card and...

Page 5: ...ndalone Access Controller B6 EH Plus EM HID Infrared 12 B6 IC Plus IC CPU Infrared 12 Single door Standalone Access Controller B6K EH Plus EM HID Own 12 B6K IC Plus IC CPU Own 12 Double doors Standalo...

Page 6: ...elow The product wiring colors and functions are shown in the following table Color Symbol Functions Light green AC2 One port of the AC power supply Blue NO Normal open port of Relay Purple COM Common...

Page 7: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 7...

Page 8: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 8...

Page 9: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 9...

Page 10: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 10...

Page 11: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 11...

Page 12: ...B6 Plus Series Standalone Access Controller User Manual V1 0 Sebury Technology Co Ltd http www sebury com cn 12...

Page 13: ...or parameter when you type this key it means input is finished means cancel current operation or back to previous menu Management menu fix to 2 digits from 00 99 Don t press on the menu behind after i...

Page 14: ...does not sure about the mode please set it again the steps please follow 03 1 3 4 Set door opening time to 2S The factory default door opening time is 2S so if user request factory default time then...

Page 15: ...r operation If the Admin Password is correct the indicator light will turn to green once and then back to red flash status Other operations must be performed in this status If the user forget the admi...

Page 16: ...rd read card Set 1 3 Normal open cards Note Each type of admin card can be divided several times to set till to 3pcs 4 1 4 Delete admin card 02 0000 delete all 21 admin cards in this zone 02 0 delete...

Page 17: ...ID numbers to add user card Read card continuously to add user 10 read card read card Input 8 digit format card number to add user 10 8 8 digit format card number 8 8 digit format card number Input 10...

Page 18: ...at the same time till to all card is added In order to prevent duplication of card numbers please delete all user cards and admin cards before add serial number cards 4 1 9 Delete user Delete all user...

Page 19: ...ble users to use Notes A better way to implement the limits of user mode is operation by Authorization card it can switch to disable and enable users to operate quickly The operation of Authorization...

Page 20: ...10 45 1 99 default value is 10 set time locked after the error operation indicate maximum times from1 to 99minutes Note Anti crack function refers to prevent illegal and unlimited password or card cr...

Page 21: ...only concern normal users operation such as the sound of opening door by PINs or read cards When you press the key for 2 seconds the buzzer is forced to enable such as entering the management menu or...

Page 22: ...ut RS232 TTL HEX format 61 2 D0 output RS232 TTL ASCII 8 format 61 3 D0 output RS232 TTL ASCII 10 format Note The wiegand format is an international protocol for access control products But the width...

Page 23: ...100 5 0101 6 0110 7 0111 8 1000 9 1001 1010 0 0000 1011 Single key output 6 bits wiegand data with parity bit E very key output a 6 bit data Corresponding relation is 1 000010 2 000100 3 000111 4 1010...

Page 24: ...d indicate exiting add user card state 4 2 3 Delete card operation Read Delete card read user card read user card read Delete card Note Delete card is mainly used for rapid continuously to delete the...

Page 25: ...by the user card The user card and the user PIN are divided into first zones and second zones they operate the door of the corresponding zone respectively The number of user PIN is specified zone 1 is...

Page 26: ...it to the initial password by special operation Operation as follows Power off press the keys do not move and power on Release the key after two beep Admin password has restored to 888888 But the oth...

Page 27: ...ting is the same with the zone 1 With 7 digit Admin Password into management mode only menus 00 01 02 10 12 21 22 30 36 are valid 4 5 4 Operation characteristics in Interlock mode Interlock mode is re...

Page 28: ...me to 1 99 minutes 41 0 Disable Anti dismantle alarm 0 1 Enable Anti dismantle alarm 42 0 Alarm lead output alarm signal voltage 0 1 Alarm lead output doorbell signal voltage 50 0 Indicator light is a...

Page 29: ...ts wiegand data no check bit 0 1 Single key output 6 bits wiegand data with parity bit 2 Single key output 8bits wiegand data with complement check bit 3 4 digit key buffered output 4 1 5 digit key ke...

Page 30: ...ers 10 10 digit format card number 10 10 digit format card number Input 10 digit format card number to add users 11 ID read card ID read card Specify ID number and read card to add user ID 8 8 digit f...

Page 31: ...t the alarm time to 0 means no alarm 0 1 99 Set the alarm time to 1 99 minutes 41 0 Disable anti dismantle alarm function 0 1 Enable anti dismantle alarm function 42 0 Alarm lead output alarm signal v...

Page 32: ...tent as shown in the following table Way to enter menu Hold down for more than 2 seconds 2 Admin password Menu Parameter or operation step Function Default value 00 8 digit PIN Set super PIN 0000 Dele...

Page 33: ...digit format number 8 8 digit format number Specified ID number and input 8 digit format card number to delete user 10 10 digit format number 10 10 digit format number Specified ID number and input 10...

Page 34: ...ase the brightness of the backlit 55 1 1 Decrease the keypad tone 10 2 2 Increase the keypad tone 6 Precautions in use Lead line cannot be connected wrong especially the power line otherwise the machi...

Page 35: ...password Change by Setting card or press the key to initialize Can enter management mode but part of the menu is invalid 1 can t setting some menu in default password only can change admin password Ch...

Reviews: