SmartEAR installing and programming 

 

 

31 

The installation wizard leads to the installation step 

Transmission test

Here  you  can  test  the  communication  chain  between  SmartEAR  logger  and 
POSEYEDON Cloud. 

Proceed as follows: 

Step  Description 

Tap the Start button 

 bottom right. 

Result:

 The screen lists the individual steps of the test.   

 

 

Successfully completed steps receive a green tick. 

 

Steps that have not been completed successfully receive a red 
exclamation mark.  
Tap the Info symbol 

 of the relevant step to get more information about 

the error occurred. 

The test ends automatically as soon as all listed steps have been completed. 

If you want to stop the test beforehand, tap the Stop button 

 bottom right. 

 

Using the Refresh button 

 bottom left you can repeat the test.  

The arrow button 

 bottom right takes you to the next installation step. 

Next step Schritt 

Summary of Contents for 1014081

Page 1: ...sue 0 09 2022 EN Article number 87869 Mess und Ortungstechnik Measuring and Locating Technologies Elektrizit tsnetze Power Networks Kommunikationsnetze Communication Networks Rohrleitungsnetze Water N...

Page 2: ...Consultation with SebaKMT 2...

Page 3: ...question remain unanswered or should you need the help of an authorized service station please contact Megger Germany GmbH Dr Herbert Iann Str 6 96148 Baunach Germany T 49 9544 68 0 F 49 9544 22 73 E...

Page 4: ...MT are hereby limited to a period of 12 months from the date of delivery Each component supplied by SebaKMT within the context of warranty will also be covered by this warranty for the remaining perio...

Page 5: ...nical description 10 3 1 Device design 10 3 2 Power supply 12 4 First use SIM card Battery 13 4 1 Introduction and warnings 13 4 2 First use 13 4 3 Changing the SIM card 15 4 4 Changing the battery 15...

Page 6: ...CAUTION Indicates a potential hazard which may result in moderate or minor injury if not avoided NOTICE Indicates a potential hazard which may result in material damage if not avoided Serves to highli...

Page 7: ...ne complies with the limit curve B living area the radiation level complies with the limit curve A industrial area according to EN 55011 Given that living areas are sufficiently far away from the plan...

Page 8: ...nics Processor 32 bit Anti theft protection Motion sensor On Off Magnetic switch Power supply Power supply Lithium battery 3 6 V 13 Ah Battery lifetime Up to 9 years Battery change Possible on site IP...

Page 9: ...l loop rod antenna magnet adapter and battery 1014081 003 SmartEAR NB IoT noise logger with SIM card Telekom EU extended incl loop rod antenna magnet adapter and battery 1014081 004 SmartEAR NB IoT no...

Page 10: ...M1 Sticker with the identification number ID of the unit Each SmartEAR logger has its own six digit identification number ID with which the device can be uniquely identified and managed Magnetic foot...

Page 11: ...ected to SmartEAR GO ON for 4 seconds then flashes 5 times then OFF When switching off OFF Unit is switched on but inactive sleep mode or Unit is switched off Inside the SmartEAR housing is the electr...

Page 12: ...ithium ion battery The battery can be inserted or replaced by the user The battery used must meet the following criteria Parameter Value Type Lithium battery Size D cell Quantity 1 Rated voltage 3 6 V...

Page 13: ...ing The unit should be opened at medium ambient temperature If the unit was previously in a cold environment it should first be allowed to acclimate at medium ambient temperature before it is opened O...

Page 14: ...ave a SIM card insert one Nano SIM 7 Before closing the unit with the housing again make sure that the O rings on the electronics module are clean The inside of the housing must be clean and dry 8 Pla...

Page 15: ...hanging the battery To change the SmartEAR battery open the device as described in section 4 2 Remove the existing battery and insert the new one The positive pole of the battery must point upwards It...

Page 16: ...egular intervals To switch off the unit hold the magnet over the area between the I O symbol and the antenna for 4 seconds The LED lights up continuously during this time As soon as the light changes...

Page 17: ...g system The app SmartEAR GO must be installed on the device 6 2 Download and installation The app is available in the App Store and in the Google Play Store 6 3 Call up the app W hrend der Installati...

Page 18: ...of a SmartEAR logger that has not yet been paired with your mobile device a dialogue appears on the screen There you will be asked to pair the logger with the mobile device Confirm this request The B...

Page 19: ...ntenna test This function allows you to test the quality of the mobile phone connection Realtime measurement With this function you can start a measurement and follow the recorded values in real time...

Page 20: ...like step by step if it is carried out with the help of the installation wizard Settings Here you can access the basic settings of the SmartEAR GO app Help Support If you have questions about SmartEA...

Page 21: ...ter your POSEYEDON access data once in the SmartEAR GO App This step is elementary Without this step the suspension of the SmartEAR loggers is not possible Proceed as follows Step Description 1 Tap th...

Page 22: ...d for the app interface Proceed as follows Step Description 1 Tap the Menu icon in the top left of the Start screen 2 Tap on Settings 3 Tap on Light theme to switch between the day theme and the night...

Page 23: ...antenna mounted o switched off Mobile device smartphone or tablet o access to the internet GPS location function bluetooth interface o SmartEAR GO app installed o POSEYEDON access data entered to the...

Page 24: ...device Confirm this request The Bluetooth connection between the two devices is established You will read CONNECTED on the screen The SmartEAR GO Main menu for the logger in question opens If no dial...

Page 25: ...lable for working with the SmartEAR logger 7 Tap Deploy to start the installation wizard In principle you can find all the steps necessary for installing and programming the logger here and carry them...

Page 26: ...e installation Viewed from left to right each bar represents one of the installation steps green Successfully completed step gelb Step not successfully completed blau Current step grau unfinished step...

Page 27: ...when the display is permanently in the green or light green area In this case you can end the test by pressing the Stop button The signal is considered poor or insufficient if the display is permanent...

Page 28: ...hin the map with your finger This has no effect on the determined GPS coordinates You can give this measuring point a name and create a helpful comment about it Use the input fields Using the Refresh...

Page 29: ...rval 30 min 60 min To set a measurement profile proceed as follows Step Description 1 Tap on Measurement profile 2 Select a profile from the list 3 Use the OK button to confirm 4 Use the Download butt...

Page 30: ...tion 1 Tap the Start button bottom right Result The measurement is initialised the logger starts measuring The course of the measurement is displayed on the screen 2 Tap the Stop button bottom right t...

Page 31: ...est Successfully completed steps receive a green tick Steps that have not been completed successfully receive a red exclamation mark Tap the Info symbol of the relevant step to get more information ab...

Page 32: ...s The symbol next to a step indicates whether the respective step has been completed successfully Use the arrow buttons bottom left to return to the individual steps to repeat them Use the Tick button...

Page 33: ...ie z me nor da ka iztr d jumu uz kura t atrodas nedr kst izmest kop ar parastiem m jsaimniec bas atkritumiem T k tas ir izstr d jums ko cits citam p rdod un lieto tikai uz mumi tad to nedr kst ar izme...

Reviews: