programming is complete. To enable the Aries (ramming) effect 
at   the   power   configured   using   the  VR1   Trimmer,   repeat   the 
above procedure, pressing the SEL key twice (the CODE PED 
Led flashes quickly) instead of once. Repeat the operation to 
restore the previous configuration. 
In this way the lock can be unlocked and the opening  phase 
can be executed correctly. Before starting the opening process, 
the control unit sends a closing command for 2 seconds, at a 
power associated with the selection.

E) T. MOT. (Closure strike):

The   control   unit   is   supplied   by   the   manufacturer   with   the 
closure   strike   function   not   enabled.   To   enable   the   function, 
proceed as follows: check the extended menu is enabled (the 
T. PAUSA and RIT. ANTE LEDs flash in alternation), press the 
SEL key until the T. MOT. LED flashes, then press the SET 
key: the T. MOT. LED turns on and programming is complete. If 
you wish to enable the Closure strike function at the configured 
power   with   the   VR1   trimmer,   repeat  the   above   procedure, 
pressing the SEL key twice (the T.MOT. Led flashes quickly) 
instead of once. Repeat the operation to restore the previous 
configuration. 
If Deceleration during closing is programmed, the control unit 
will add 1-sec time at the power associated with the selection 
(after   completing   the   decelerated   closing   phase)   in   order   to 
overcome the lock, if present. 

F) T. MOT. PED.  ( Follow Me ) :

The control unit is supplied by the manufacturer with the Follow 
Me function not enabled. To enable the function, proceed as 
follows: check the extended menu 1 is enabled (the T.PAUSA 
and RIT ANTE LEDs flash in alternation),  press the SEL button 
until the T.MOT.PED Led flashes, then press the SET key; at 
the   same   time   the   T.MOT.PED   LED   turns   on   and   remains 
steady and programming is complete. In this way the control 
unit   executes   the   closing   phase   immediately,   ignoring   the 
configured operating logics, if it detects transit with activation of 
the photocell connected  to the DS input  during the opening, 
Pause and Closing phases.
Repeat the operation to restore the previous configuration.

EXTENDED MENU 2 

    

The control unit is supplied by the manufacturer with  only the 
option   of   directly   selecting   the   functions   listed   in   the   main 
menu. 
To enable the functions listed in Extended Menu 2, proceed as 
follows: open Extended Menu 1 (as instructed in the respective 
section), then press and hold the SET key for 5 seconds; the 
T.PAUSA and   RIT ANTE LEDs  flash  at  the  same  time;  you 
have 30 seconds to select the functions of Extended Menu 2 
using the SEL and SET buttons; after another 30 seconds, the 
control unit returns to the main menu.

----------------------    EXTENDED MENU  2    -----------------

Led reference           Led off                        Led on

A) TIPO MOTORE   Remote PGM = OFF     Remote PGM = ON      
B) AUTO PGM    Photocell test= OFF      Photocell test = ON
C) CODE  Pre-flash and Cour. light=OFF Pre-flash or Cour. light=ON 
D) CODE PED.   Flash in Pause = OFF      Flash in Pause = ON    
E) T. MOT.         

PUL=PUL/PED=PED    PUL=PUL/PED=DS AUX1/2

F) T.MOT.PED.  PUL=PUL / PED=PED              PUL=AP / PED=CH
G) T. PAUSA                     Flash ON/OFF simultaneously 
H) RIT. ANTE                    Flash ON/OFF simultaneously                   

A) TYPE OF MOTOR 
(Remote programming of radio control):

The   control   unit   enables   remote   programming   of   the 
transmission code, without using the SEL key.
To program the transmission code in remote mode, proceed as 
follows:   send   the   previously   stored   radio   control   code 
continuously for more than 10 seconds and the control unit will 
enter the programming mode as described above for the CODE 
Led in the main menu.
The control unit is supplied by the manufacturer with  remote 
programming of the transmission code not enabled; to enable 

the function proceed as follows: check the extended menu 2 is 
enabled   (the   T.   PAUSA   and   RIT.   ANTE   LEDs   flash 
simultaneously), press the SEL button until the TIPO MOTOR 
LED flashes, then press the SET key, at the same time the LED 
TIPO MOTOR turns on and remains steady and programming 
is   complete.   Repeat   the   operation   to   restore   the   previous 
configuration.

B) AUTO PGM (Photocell Test):

The   control   unit   is   supplied   by   the   manufacturer   with 
programming   of   the   Photocell   Test   disabled;   to   enable   the 
function (in accordance with standard EN 12453), proceed as 
follows: check the extended menu 2 is enabled (the T. PAUSA 
and   RIT.   ANTE   LEDs   flash   simultaneously),   press   the   SEL 
button until the AUTO PGM Led flashes, then press the SET 
key,   at   the   same   time   the   LED   AUTO   PGM   turns   on   and 
remains steady and programming is complete. In this way, the 
Photocell   connected   to   the   DS   input   is   tested   before   the 
automation starts any of the phases. 
Repeat the operation to restore the previous configuration.  If 
not used, the DS input must be jumped and the Photocell Test 
disabled.

C) CODE (Pre-flash/ Courtesy Light):

The control unit is supplied by the manufacturer with  the Pre-
flash and Courtesy Light functions not enabled. To enable the 
Pre-flash   function,   proceed   as   follows:   check   the   Extended 
Menu 2 is enabled (the T. PAUSA and RIT. ANTE LEDs flash 
simultaneously),     press   the     SEL   key   until   the   CODE   LED 
flashes, then press the SET key, at the same time the CODE 
LED   turns   on   and   remains   steady   and   programming   is 
complete.   To   enable   the   Courtesy   light   function,   repeat   the 
above procedure, pressing the SEL key twice (the CODE LED 
flashes   quickly)   instead   of   once.   Repeat   the   operation   to 
restore the previous configuration. 

Pre-flashing: 

The 12 Vdc 4 W light output is always activated 

3 seconds before the automation starts any of the phases. 

Courtesy light: 

The 12 Vdc 4W light output is activated for 3 

seconds whenever an opening command is transmitted.

D) CODE PED (Use of the Flashing Beacon) :

The control unit is supplied by the manufacturer with use of the 
flashing   beacon  during   the  Pause  Time disabled.  To  enable 
use   of   the   flashing   beacon,   check   the   Extended   Menu   2   is 
enabled   (the   T.   PAUSA   and   RIT.   ANTE   LEDs   flash 
simultaneously),  press the  SEL key until the CODE PED LED 
flashes, then press the SET key, at the same time the CODE 
PED LED turns  on  and  remains  steady  and  programming  is 
complete.   Repeat   the   operation   to   restore   the   previous 
configuration.

E) T. MOT. (Selection of the PED / DS AUX1-AUX2 input) : 

The control unit is supplied by the manufacturer  with a PED 
input for connecting a cyclical (NO) Pedestrian control button. 
To select use of the input as  DS AUX 1, proceed as follows: 

check   the   Extended   Menu   2   is   enabled   (

the   T. 

PAUSA and RIT. ANTE LEDs flash simultaneously), press the 
SEL key until the

 

T.MOT. LED flashes, then press the SET key, 

at the same time the T.MOT. LED turns on and remains steady 
and programming is complete

.

Repeat the operation to restore the previous configuration. 
To   select   use   of  the   input  as  DS  AUX 2,  repeat   the  above 
procedure for use as DS AUX 1, pressing the SEL key twice 
(the T. PAUSA and RIT. ANTE LEDs flash quickly and at the 
same time) instead of once.
Repeat the operation to restore the previous configuration.

F) T. MOT. PED. (Selection of the PUL and PED inputs) :

The control unit is supplied by the manufacturer with  a PUL 
control input for connecting a cyclical (NO) main control button, 
and   a   PED   control   input   for   connecting   a   cyclical   (NO) 
Pedestrian control button. To select a different use for the PUL 
and PED inputs, proceed as follows: check the Extended Menu 
2   is   enabled   (the   T.   PAUSA   and   RIT.   ANTE   LEDs   flash 

                                                                                            4                                                      Rev. 1.0    08/10/2010

Summary of Contents for LRS 2239

Page 1: ...ommand impulse is received before the activation of the limit switch the direction of movement of the mechanism will be reversed whether engaged in opening or closing operations Step by step Using either the radio control CODE led lit or the low tension button panel PUL to operate the gates commands will have the following effect the first command impulse activates the opening mechanism either for...

Page 2: ... key selects the type of function to be stored selection is indicated by a flashing LED By pressing the key repeatedly you can select the desired function The selection remains active for 10 seconds indicated by the flashing LED after 10 seconds the control unit returns to its original status SET key programmes the information according to the type of function selected previously using the SEL key...

Page 3: ... key to the RIT ANTE LED when flashing press the SET key wait for the desired interval of time then press the SET key again the fixed door delay time of 2 seconds during opening is stored the door delay time during closing is stored for the programmed time and the RIT ANTE LED is on To restore the initial configuration without door delay go to the RIT ANTE LED when flashing then press the SET key ...

Page 4: ...f the transmission code not enabled to enable the function proceed as follows check the extended menu 2 is enabled the T PAUSA and RIT ANTE LEDs flash simultaneously press the SEL button until the TIPO MOTOR LED flashes then press the SET key at the same time the LED TIPO MOTOR turns on and remains steady and programming is complete Repeat the operation to restore the previous configuration B AUTO...

Page 5: ... the TIPO MOTORE AUTO PGM and CODE LEDs are steady while the CODE PED Led flashes press SET to confirm The default setting is Level 3 RESET To restore the default configuration press the SEL and SET keys simultaneously all RED LEDs will light up and then switch off DIAGNOSTICS Photocell test The control unit can be fitted with safety devices in accordance with step 5 1 1 6 of the EN 12453 standard...

Page 6: ...back of the casing is set up for mounting on a wall holes for mounting with nogs or holes for screws Take all precautions to ensure the IP degree of protection is not affected during installation If applicable the keypad for manual control must be mounted in such a way as not to compromise the safety of the user The motor reducer used to move the shutter must comply with section 5 2 7 of EN 12453 ...

Page 7: ...7 Rev 1 0 08 10 2010 ...

Reviews: