Initial pick-up and motor power adjustment:

The electronic control unit is equipped with a VR1 trimmer for 
initial   pick-up   and   motor   power   adjustment   that   are   fully 
managed by the microprocessor. Adjustment can be within a 
range of 50% to 100% of max power.

Warning: you  will need  to repeat   the teach-in phase  if  
you wish to adjust the VR1 trimmer as the operation and  
deceleration times may be affected. 

Obstacle detection:

The electronic control unit has a VR2 trimmer for adjusting the 
power required to detect obstacles. You can control this entirely 
from the microprocessor. 
The trimmer’s activation time can be set between a minimum of 
0.1 seconds and a maximum of 3 seconds.

Warning:

- When limit switches are connected to the control unit, the  
detection of an obstacle causes the motor to change direction  
during the closing phase and reverse for 2 seconds during  
the opening phase.
- When no limit switches are connected to the control unit,  
the   detection   of   an   obstacle   always   causes   the   motor   to  
change direction during the closing phase (and then take 5  
seconds   to   close)   and   reverse   for   2   seconds   during   the  
opening phase (and then take 5 seconds to stop).

Deceleration:

The   motor   deceleration   function   is   used   to   avoid   the   gates 
moving   at   high   speed   towards   the   end   of   the   opening   and 
closing stages.
  Deceleration   can   be   programmed   for   the   desired   points 
(before the gates are totally open or closed) during Motor Timer 
programming.

Warning light:

The centre allows the connection of a 12Vdc 3 W (max) 

light to show the state of the automation process. Light off 
automation   closed,   access   open,   slow   flashing   motor 

open, fast flashing motor closing.

Functioning of the Flasher or courtesy light:

The  control   unit   has   an   output   for   the   use   of   a   flasher   of 
12/24*Vdc   4W   max.   Its   use   is   conditioned   by   the   settings 
selected in Extended Menu 2. 

Electric lock control Output:

The control unit has an output for the use of electric locks of 
12/24*Vdc 12W max. It is activated for 2 seconds during each 
initial opening phase.

Buffer battery:

The control unit has an incorporated 13.7 Vdc battery charger 
(you   need   to   use   12V   batteries,   even   for   24V   motors).   The 
control unit can be fitted with a buffer battery not exceeding 
7Ah in capacity, which can be used for up to 20/30 complete 
phases. The flashing light, if fitted, turns on for only the first 4 
seconds of the phase in the event of a power cut.

Solar panel:

The control unit can be fitted with a solar panel for charging the 
emergency battery.

Operation with TIMER:

The control unit may be connected to a timer instead of using 
the open-close command button (PUL).
Example:   at   8:00   a.m.  the   timer   closes   the   contact   and   the 
control unit opens the gate; at 6:00 p.m. the timer opens the 
contact and the control unit closes the gate. Between 8:00 a.m. 
and 6:00 p.m. at the end of the opening phase, the control unit 
disables the flashing beacon, the automatic closing stage and 
the radio controls.

PROGRAMMING:

SEL key:

 selects the type of function to be stored; selection is 

indicated by a flashing LED.
By   pressing   the   key   repeatedly,   you   can   select   the   desired 
function.   The   selection   remains   active   for   10   seconds 
(indicated by the flashing LED); after 10 seconds, the control 
unit returns to its original status.

SET key:

 programmes the information according to the type of 

function selected previously using the SEL key.

IMPORTANT

:  The  function  of  the  SET key  can  be  replaced 

with the radio control, if programmed previously (CODE LED 
on).

MAIN MENU

The control unit is supplied by the manufacturer with the option 
of selecting a number of principal functions.

---------------------- MAIN MENU -----------------

Led reference             Led off                        Led on

1) TIPO MOTOR        Linear                                  Variable
2) AUTO PGM      Automatic PGM = OFF       Automatic PGM = ON
3) CODE                  No code                          Code activated
4) CODE PED.         No code                          Code activated
5) T. MOT.           30 sec. activity                     Programmed delay
6) T.MOT.PED.    10 sec. pedestrian activity   Programmed delay
7) T. PAUSA.       No automatic close              Automatic close
8) RIT. ANTE        No gate delay                     Programmed delay

1) TYPE OF MOTOR:

The   control   unit   has,   by   default,   the   operating   logic   for 
connecting   linear   actuators   (TIPO   MOTORE   Led   off).   To 
enable the operating logic for connecting variable consumption 
motor reducers (TIPO MOTORE Led on), proceed as follows: 
press   the   SEL   button   until   the   TIPO  MOTORE  Led   flashes, 
then press the SET button. The TIPO MOTORE Led turns on 
and   remains   steady.   Repeat   the   procedure   to   restore   the 
previous configuration.

2) AUTO PGM:

The control unit allows you to execute (Simplified) Automatic 
Programming.
Firstly, move the gates to their half-way position, press the SEL 
button until the AUTO PGM flashes, then press and hold the 
SET button; Motor 2 executes the closing phase up to the limit 
switch or stop, and then Motor 1 does the same. If the motors 
move in the wrong direction, release the SET button, unplug 
the control unit and connect the wires properly to the motors. If 
instead   the   motors   act   as   required,   the   control   unit   should 
execute a complete opening and closing phase and therefore 
the entire auto programming procedure (you need to press and 
hold  the  SET  button  until  the  end  of  the  Auto   Programming 
procedure).
At   the   same   time,   the   deceleration   cycle   is   automatically 
configured at 15% of the complete cycle.

During automatic programming, you can use the radio control  
key   on   the   control   unit   instead   of   the   SET   key,   if   stored  
previously.

3) CODE: 

 (Radio control code)

The control unit can store up to 150 radio controls with different 
fixed or rolling codes.

Programming

 

 .  

To programme the transmission code, proceed as follows: 
press the SEL key until the CODE LED flashes and send the 
desired code with the relevant radio control; programming is 
completed when the CODE LED turns on and remains steady. 

If you have stored 150 codes and you repeat the programming  
operation, all the programming LEDs will start flashing to  
indicate that no more codes can be stored.

Deleting the codes

 

 .  

All   the  stored   codes   are   deleted   as   follows:   press   the   SEL 
button until the CODE led flashes, then press the SET button 
and the CODE led turns off and the codes are deleted.

4) CODE PED: 

(Pedestrian radio control code) 

                                                                                            2                                                      Rev. 1.0    08/10/2010

Summary of Contents for LRS 2239

Page 1: ...ommand impulse is received before the activation of the limit switch the direction of movement of the mechanism will be reversed whether engaged in opening or closing operations Step by step Using either the radio control CODE led lit or the low tension button panel PUL to operate the gates commands will have the following effect the first command impulse activates the opening mechanism either for...

Page 2: ... key selects the type of function to be stored selection is indicated by a flashing LED By pressing the key repeatedly you can select the desired function The selection remains active for 10 seconds indicated by the flashing LED after 10 seconds the control unit returns to its original status SET key programmes the information according to the type of function selected previously using the SEL key...

Page 3: ... key to the RIT ANTE LED when flashing press the SET key wait for the desired interval of time then press the SET key again the fixed door delay time of 2 seconds during opening is stored the door delay time during closing is stored for the programmed time and the RIT ANTE LED is on To restore the initial configuration without door delay go to the RIT ANTE LED when flashing then press the SET key ...

Page 4: ...f the transmission code not enabled to enable the function proceed as follows check the extended menu 2 is enabled the T PAUSA and RIT ANTE LEDs flash simultaneously press the SEL button until the TIPO MOTOR LED flashes then press the SET key at the same time the LED TIPO MOTOR turns on and remains steady and programming is complete Repeat the operation to restore the previous configuration B AUTO...

Page 5: ... the TIPO MOTORE AUTO PGM and CODE LEDs are steady while the CODE PED Led flashes press SET to confirm The default setting is Level 3 RESET To restore the default configuration press the SEL and SET keys simultaneously all RED LEDs will light up and then switch off DIAGNOSTICS Photocell test The control unit can be fitted with safety devices in accordance with step 5 1 1 6 of the EN 12453 standard...

Page 6: ...back of the casing is set up for mounting on a wall holes for mounting with nogs or holes for screws Take all precautions to ensure the IP degree of protection is not affected during installation If applicable the keypad for manual control must be mounted in such a way as not to compromise the safety of the user The motor reducer used to move the shutter must comply with section 5 2 7 of EN 12453 ...

Page 7: ...7 Rev 1 0 08 10 2010 ...

Reviews: