SeasonsComfort 269800 Owner'S Manual Download Page 4

WARNING:

READ ALL SAFETY INFORMATION AND INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN INSTALLING THE 

FAN AND SAVE INSTRUCTIONS.

All set screws of the fan must be checked and retightened where necessary before installation.
To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets,  balancing 

the blades or cleaning fan. Do not insert foreign objects in between rotating fan blades.
Before changing the fan direction, turn off the fan and wait for the fan blades to stop completely.
If a stationary appliance is not provided with a supply cord and a plug, or with other means for  

disconnection from the main supply having a contact separation of at least 3 mm in all poles, that  means for 

disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
The safeguards provided by these safety instructions and by the separate installation  instructions are not 

meant to cover all possible conditions and situations that may occur. It must be  understood that common 

sense, caution and care are factors which can not be built into this product.  These factors must be supplied 

by the person(s) installing, caring for and operating the fan.
The fan weight is

 

Net Weight: 13.58 lb (6,16 kg). Be sure the outlet box (not included) is securely attached 

to the building structure and is marked “Acceptable For Fan Support”.  Failure to do so can result in serious 

injury.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 

to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses and can radiate radio frequency 

energy and, if not installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not occur in a particular 

installation. If this equipment does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to correct the interference by 

one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver
--Connect the equipment into and outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
Please note changes or modifications not expressly approved by the party responsible for compliance could 

void the user’s authority to operate the equipment.

To avoid risk of electric shock, be sure to shut off power at the main  fuse or circuit breaker box before 

installing or servicing this  fixture. Turning off the electrical power by using the light switch  is not 

sufficient to prevent electrical shock.

To reduce the risk of injury, install the fan so that the blades are  at least 7 feet (2.1 Meters) above the 

floor and at least 18 inches  (0.5 Meters) from the tip of the blades to the wall.  

To reduce the risk of fire, electric shock, or personal injury, mount  to outlet box marked “acceptable for 

fan support” and use mounting  screws provided with the outlet box.

The installation has to be in accordance with the national electrical  code, ansi/nfpa 70-1999 and local 

codes. If you are unfamiliar with the  methods of installing electrical wiring, seek the services of a  

qualified licensed electrician.

SAFETY INSTRUCTIONS

4

CAUTION:

Summary of Contents for 269800

Page 1: ...armateo 42 LED Ceiling Fan Owner s Manual 1 Part 269800 Exclusively Distributed By HD Supply Facilities Maintenance Ltd Atlanta GA 30339 2019 Made in China To Reorder 1 800 431 3000 hdsupplysolutions com ...

Page 2: ...s Manual 19 Mounting Bracket Screw x4 20 Closemount Screw x3 21 Set Screw x2 22 Wire Connector x3 23 Pull Chain Extension x2 24 Blade Screw x4 25 Blade Washer x4 Unpack your fan and check the contents You should have the following items PACKAGE CONTENTS HARDWARE CONTENTS Note Some extra hardware has been included The quantity listed above is the number required for installation 22 23 24 25 Hardwar...

Page 3: ...d is best suited for ceilings lower than 8 feet It does not utilize the downrod Downrod Mount is best suited for ceilings 8 ft or higher For taller ceilings you may want to use a longer downrod not included Angled Ceiling Mount is best suited for angled or vaulted ceilings A longer downrod is sometimes necessary to ensure proper blade clearance from the ceiling If using the angle mount check to en...

Page 4: ...tial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be dete...

Page 5: ...arked acceptable for fan support and use the mounting screws and washers provided with the outlet box 4 4 CLOSEMOUNT INSTALLATION OPTIONAL a Remove the three Phillips head closemount screws from the top of the motor assembly b Remove the canopy cover from the bottom of the canopy c Align the holes in the bottom of the canopy with the screw holes in the top of the motor housing The larger holes in ...

Page 6: ...ded Then strip 1 2 of insulation from the end of each wire 8 Lift the downrod into the mounting bracket Rotate the downrod until the tab in the mounting bracket is seated in the slot in the downrod ball WARNING The fan and or downrod should not rotate in the mounting bracket if installed correctly Failure to align the slot in the downrod ball with the tab may result in fan falling causing serious ...

Page 7: ... supply wire Connect the white wire from the fan to the white neutral common supply wire Connect the black and blue wires from the fan to the black live hot supply wire Note If there is a second hot power wire coming from the outlet box connect it to the blue light power fan wire for separate light and fan control Important After the connections have been made the connected wires should be turned ...

Page 8: ...Glass Shade 16 Pull Chain Extension 16 Attach pull chain extensions to the pull chains 13 14 Single pin Connectors Switch Housing Screw Reverse Switch Notch To install the fan without the light kit skip to step 17 13 Remove the three switch housing screws from the top edge of the light kit Then connect the single pin connectors from the fan to the single pin connectors from the light kit blue to b...

Page 9: ...an help move stagnant hot air off the ceiling area Reverse Switch 18 18 Restore power at the main fuse or circuit breaker 17 INSTALLATION WITHOUT LIGHT KIT OPTIONAL a Remove the three switch housing screws from the switch housing at the top of the light kit b Attach the switch housing cap to the switch housing using the three previously removed switch housing screws Note Align the notch in the swi...

Page 10: ...om Solid State variable speed controls DO NOT USE a Solid State variable speed control 1 Ensure all blades are screwed firmly into blade arms 2 Ensure all blade arms are tightened securely to motor 3 Ensure canopy and mounting bracket are tightened securely to outlet box and outlet box is mounted firmly to ceiling joist 4 Switch one blade with a blade from the opposite side Or balance the fan usin...

Page 11: ...e of any kind including any incidental or consequential damages resulting directly or indirectly from any breach of warranty express or implied or any other failure of this product Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you If the original purchaser ceases to own the fan this warranty is voided Should the purc...

Reviews: