background image

6

Part Number

Key

Model

Model

Part

No.

390.250290

390.251590

Qty

Description

1

J218-971AC

J218-972AC

1

Motor

2

U36-856ZP

U36-856ZP

4

Screw

3

C69-7

C69-7

1

Slinger

4

N3-13P

N3-13P

1

Seal Plate

5

U9-402

U9-402

1

Seal (Square Cut)

6

2784

2784

1

Shaft Seal

7

J105-42PV

J105-42PW

1

Impeller

8

N1-29P

N1-29P

1

Diffuser/Venturi

9

U9-401

U9-401

1

Seal (Square Cut)

10

N76-39P

N76-39P

1

Pump Body

11

WC78-39T

WC78-39T

1

1/2” NPT Cleanout Plug

1

2

3

4

5

6

7

8

9

15

16

17

18

12

10

11

13

14

19

20

Cut tubing carefully
to remove.
Do not damage barb.

PUMP DISASSEMBLY

REPAIR PARTS LIST

1

2

3

4

Part Number

Key

Model

Model

Part

No.

390.250290

390.251590

Qty

Description

12

U212-68T

U212-68T

1

Drain Cock

13

WC78-41T

WC78-41T

1

1/8” NPT AVC Plug

14

U36-52ZP

U36-52ZP

8

Capscrew

15

U211-211T

U211-211T

1

Straight Hose Barb

16

U36-36ZP

U36-36ZP

8

Nut

17

U37-665P

U37-665P

1

Pressure Switch Tube

18

2764

2781

1

Pressure Switch

19

U36-112ZP

U36-112ZP

1

Lock Ring

20

L43-5C

L43-5C

1

Connector

F642-9206

F642-9206

1

Owner’s Manual

Hold motor fan

To order parts, call:

Sears Product Service

1-800-366-7278

Pump Mounting 
Bracket

Adapter
Bracket

N O T I C E

N O T I C E

If you are installing your pump on an
older Captive-Air tank with small pump
mounting bracket, use a package N198-3
adapter bracket for a firmer installation.
Package includes adapter and all required
hardware. Bolt adapter to pump mounting
bracket and pump to adapter bracket with
carriage bolts provided in kit.

This pump may have a spacer shim inserted
inside the impeller hub to assure correct
running clearance between impeller  and
seal plate (see illustration at left).
This shim may stick inside impeller hub
when impeller is removed.
When removing impeller, look for this
shim; if it is used, make sure to save it and
replace it when reassembling pump.

Summary of Contents for HYDRO-GLASS 390.250290

Page 1: ...fore Start ing The Installation Save This Manual For Future Reference Sears Roebuck and Co Chicago IL 60684 U S A Installation Operation Repair Parts PRINTED IN U S A HYDRO GLASS SHALLOW WELL JET PUMP...

Page 2: ...childproof use padlocks and master switches remove starter keys MADE IN U S A OF U S AND FOREIGN COMPONENTS Sold by Sears Roebuck and Co Chicago IL 60684 2 FULL ONE YEAR WARRANTY ON SHALLOW WELL JET...

Page 3: ...cted to pump to prevent pump breakage 3 Wrap 1 1 2 to 2 layers of Teflon tape clockwise as you face end of pipe on all male threads being attached to pump 4 Tighten joints hand tight plus 1 1 2 turns...

Page 4: ...pply voltage must be within 10 of name plate voltage Incorrect volt age can cause fire or seriously damage motor and voids warranty If in doubt consult a licensed electrician Use wire size specified i...

Page 5: ...pump it may be necessary to reprime unit 2 3 times before all air is out of suction pipe 3 If after priming pump several times and no water is pumped make sure that a Suction pipe end is in water b S...

Page 6: ...Barb 16 U36 36ZP U36 36ZP 8 Nut 17 U37 665P U37 665P 1 Pressure Switch Tube 18 2764 2781 1 Pressure Switch 19 U36 112ZP U36 112ZP 1 Lock Ring 20 L43 5C L43 5C 1 Connector F642 9206 F642 9206 1 Owner s...

Page 7: ...deliver water to full Steel piping if used is corroded or Replace with plastic pipe where possible otherwise with new steel pipe capacity limed causing excess friction Offset piping is too small in s...

Page 8: ...Connection WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION MODEL NUMBER NAME OF ITEM All parts listed may be ordered from any Sears Service Center If the...