5. Make sure that either:

A. Motor frame is connected to pressure switch by a

solid metal connection, or

B. Motor ground wire is connected to ground terminal

in switch.

Risk of electric shock. Do not operate pump unless

motor and pressure switch are connected to each

other by a solid metal connection and are grounded.

6. Replace pressure switch cover.

Pump is now wired for operation.

Operation

Priming the pump 

Explosion Hazard. Do not run pump with

discharge shut off. Pump can boil water, causing steam
burns when opening pump or blowing up pump body or
can cause internal (seal) damage to pump.

NEVER run pump dry. Running pump with-

out water may overheat pump, damaging internal parts
and causing burns if handled. 
To prevent damage, fill
pump with water before starting.
1. Remove priming plug.

a. Fill pump and suction pipe with water. (Fig. 6)
b. Replace priming plug, using Teflon tape on plug

thread; tighten plug.
NOTICE: If priming tee and plug have been
provided for long horizontal run, be sure to fill
suction pipe through this tee and replace plug
(REMEMBER TO TEFLON TAPE THE PLUG).

c. Open faucet to allow air to escape during prime,

close faucet quickly when unit primes.

2. Start pump and run two minutes or less. Unit should

pump water. If not, stop pump and repeat steps under
No. 1. On first use of pump, it may be necessary to
reprime unit 2-3 times before all air is out of suction pipe.

3. If, after priming pump several times and no water is

pumped, make sure that:

a. Suction pipe end is in water.

b. Suction pipe has no air leaks.
c. Pump is not trying to lift water more than 20 ft. (6 M).
d. Pump is not air locked: Pump suction port should be

highest point in suction pipe; no sags in suction pipe
(run it straight and angled slightly upward from well
head to pump).

e. Piping is clean and in good condition.

NOTICE: As long as foot valve and check valve
function correctly and suction pipe does not develop
leaks, pump should not need repriming in normal
service.

Performance Chart

5

115 V Line

Black

Tracer

Black

L1

B

C

L2

Ground Wire

L1

L2

LINE

MOTOR

LINE

MOTOR

Figure 5

Branch

DISTANCE IN FEET (M) FROM MOTOR TO SUPPLY

Max. 

Fuse*

0 - 50 

51 - 100 

101 - 200 

201 - 300 

301 - 400 

401 - 500 

Model

Motor

Load

Rating

(0 - 15)

(15 - 30)

(30 - 61)

(61 - 91)

(91 - 122)

(122 - 152)

No.

HP

Volts

Amps

Amps

AWG WIRE SIZE (mm

2

)

390.250290

1/2

115/230

9.4/4.7

15

14 (2)

14 (2)

10 (5)

8 (7)

8 (7)

8 (7)

390.251590

1/2

115/230

8.8/4.4

15

14 (2)

14 (2)

12 (3)

10 (5)

8 (7)

8 (7)

WIRING CHART Recommended Wire and Fuse Sizes

Figure 6 – Priming the Pump

Model

Disch.

GPM  at depth to water

HP

PSI 

5 Ft. 

10 Ft. 

15 ft. 

20 Ft. 

390.250290

40

7.3

6.2

5.2

4.2

390.251590

40

8.2

7.3

6.2

5.0

Pump 

Pressure 

Required Tank

Model

Switch Setting

Precharge

390.250290

20-40 PSI 

20 PSI 

390.251590

30-50 PSI 

30 PSI 

Ground Wire

L1

L2

LINE

MOTOR

LINE

MOTOR

230 V Line

Black

L1

B

C

L2

Black
Tracer

Summary of Contents for HYDRO-GLASS 390.250290

Page 1: ...fore Start ing The Installation Save This Manual For Future Reference Sears Roebuck and Co Chicago IL 60684 U S A Installation Operation Repair Parts PRINTED IN U S A HYDRO GLASS SHALLOW WELL JET PUMP...

Page 2: ...childproof use padlocks and master switches remove starter keys MADE IN U S A OF U S AND FOREIGN COMPONENTS Sold by Sears Roebuck and Co Chicago IL 60684 2 FULL ONE YEAR WARRANTY ON SHALLOW WELL JET...

Page 3: ...cted to pump to prevent pump breakage 3 Wrap 1 1 2 to 2 layers of Teflon tape clockwise as you face end of pipe on all male threads being attached to pump 4 Tighten joints hand tight plus 1 1 2 turns...

Page 4: ...pply voltage must be within 10 of name plate voltage Incorrect volt age can cause fire or seriously damage motor and voids warranty If in doubt consult a licensed electrician Use wire size specified i...

Page 5: ...pump it may be necessary to reprime unit 2 3 times before all air is out of suction pipe 3 If after priming pump several times and no water is pumped make sure that a Suction pipe end is in water b S...

Page 6: ...Barb 16 U36 36ZP U36 36ZP 8 Nut 17 U37 665P U37 665P 1 Pressure Switch Tube 18 2764 2781 1 Pressure Switch 19 U36 112ZP U36 112ZP 1 Lock Ring 20 L43 5C L43 5C 1 Connector F642 9206 F642 9206 1 Owner s...

Page 7: ...deliver water to full Steel piping if used is corroded or Replace with plastic pipe where possible otherwise with new steel pipe capacity limed causing excess friction Offset piping is too small in s...

Page 8: ...Connection WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION MODEL NUMBER NAME OF ITEM All parts listed may be ordered from any Sears Service Center If the...