INTRODUCTION

Please take a few minutes to read our instructions before you
install and use your pump. This will help you obtain the full
benefits from this pump. It will also help you avoid any need-
less service costs that result from causes we cannot control
and cannot cover in our warranty.

Carefully read and follow all safety instructions in this
manual or on pump.

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for per-
sonal injury!

DANGER 

warns about hazards that will cause

serious personal injury, death or major property damage if
ignored.

WARNING 

warns about hazards that can

cause serious personal injury, death or major property dam-
age if ignored.

CAUTION 

warns about hazards that will or can

cause minor personal injury or property damage if ignored.

The word 

NOTICE 

indicates special instructions which are

important but not related to hazards.

1. To avoid risk of serious bodily injury and property dam-

age, read safety instructions carefully before installing
pump.

2. Follow local and/or national plumbing and electrical

codes when installing pump.

3. Keep the well covered while installing pump to prevent

leaves and other debris from falling into well, contami-
nating well and possibly damaging pump.

4. Protect pump and piping system from freezing. Allowing

pump or water system to freeze could severely damage
pump and voids warranty.

Hazardous Voltage. Can shock, burn,

cause death, or start fires.

5. Disconnect electrical power source before installing or

working on pump.

6. Ground pump with a ground wire run from grounding lug

on motor to a grounded lead in the service panel.

7. Line voltage and frequency of electrical power supply

must agree with motor nameplate.

8. Use of fuses or wire smaller than size recommended in

owner’s manual can cause overheating, possible fires, and
will void warranty.

9. Pump water only with this pump.

10. Do not run pump dry. To do so will damage seals and can

cause leaking and property damage.

FULL ONE YEAR WARRANTY ON CRAFTSMAN

®

SPRINKLER PUMPS

For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective in materi-
als or workmanship.

LIMITED WARRANTY ON CRAFTSMAN

®

HYDROGLASS

®

SPRINKLER PUMP

After one year and through two years from the date of purchase, Sears will furnish, free of charge, a replacement
part for any defective part. You pay for labor.

This warranty does not cover repairs on replacement parts necessary because of abuse or negligence including fail-
ure to install, adjust and operate this pump according to the instructions in the owner’s manual.

LIMITATION OF LIABILITY

SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL
LOSS OR EXPENSE FROM PROPERTY DAMAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF THIS
PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.

WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPART-
MENT IN THE UNITED STATES. 

This warranty applies only while the product is in the United States.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Sears, Roebuck and Co., Dept. 817 WA, Hoffman Estates, IL 60179

RULES FOR SAFE INSTALLATION AND OPERATION!

Summary of Contents for CRAFTSMAN HYDROGLASS 390.2622

Page 1: ...Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Maintenance Repair Parts PRINTED IN U S A HYDROGLASS HIGH PRESSURE SPRINKLER PUMP Form No F642 04710 8 6 04 MODEL NOS 390 2622 390 262553 MODEL NO 390 2623 ...

Page 2: ...t electrical power source before installing or working on pump 6 Ground pump with a ground wire run from grounding lug on motor to a grounded lead in the service panel 7 Line voltage and frequency of electrical power supply must agree with motor nameplate 8 Use of fuses or wire smaller than size recommended in owner s manual can cause overheating possible fires and will void warranty 9 Pump water ...

Page 3: ...l Add sections of pipe as needed using Teflon tape on male threads Be sure that all suction pipe is leakproof or pump will lose prime and fail to pump Install foot valve 10 to 20 feet below the low est level to which water will drop while pump is operat ing pumping water level Your well driller can furnish this information 3 To prevent sand and sediment from entering the pump ing system the foot v...

Page 4: ...joint compounds on the pump they can react with the plastic in the pump components 1 Bolt pump to solid level foundation 2 Support all piping connected to the pump 3 Wrap 1 1 2 to two layers of Teflon tape clockwise as you face end of pipe on all male threads being attached to pump 4 Tighten joints hand tight plus 1 1 2 turns Do not over tighten NOTICE Install pump as close to water source as poss...

Page 5: ...ide a correctly fused disconnect switch for protec tion while working on motor Consult local or national electrical codes for switch requirements A L1 230 Volts 115 Volts 230 Volt to 115 Volt Conversion Plug in Type Pull plug straight out from terminal board 1 1 2 2 Plug in again with arrow on plug pointing to 115 Volts Ground Screw A L1 230 Volts 115 Volts Clamp the power cable to prevent strain ...

Page 6: ...he diagram on the motor IMPORTANT 115 230 Volt single phase models are shipped from factory with motor wired for 230 volts If power supply is 115 volts remove motor canopy and re connect motor as shown in Figure 6 Do not try to run motor as received on 115 volt current 8 Motor has automatic internal thermal overload protec tion If motor has stopped for unknown reasons thermal overload may restart ...

Page 7: ...ontal run 10 of horizontal suction pipe 1 of vertical lift due to friction losses in the pipe If no water is produced within 10 minutes stop pump release all pressure remove priming plug refill and try again Hazardous pressure and risk of explo sion and scalding If pump is run continuously at no flow that is with discharge shut off or without prim ing water may boil in pump and piping system Under...

Page 8: ...r terminals together see Figure 14 Do not touch metal screwdriver blade or capacitor terminals If in doubt consult a quali fied electrician 4 Unscrew capacitor clamp and remove capacitor Do not disconnect capacitor wires to motor 5 Slide 7 16 open end wrench in behind spring loaded switch on motor end of shaft hold motor shaft with wrench on shaft flats and unscrew impeller by turning counterclock...

Page 9: ...op is sufficient to in side diameter of rotating seal member 8 Slide rotating seal member carbon face first onto shaft until rubber drive ring hits shaft shoulder NOTICE Be sure not to nick or scratch carbon face of seal when passing it over threaded shaft end or shaft shoulder The carbon surface must remain clean or short seal life will result 9 Hold motor shaft with 7 16 open end wrench on shaft...

Page 10: ...Pump has lost prime through 2 In installation already in use a Air leaks a Check all connections on suction line and shaft seal b Water level below suction b Lower suction line into water and re prime If receding water level of pump in well exceeds suction lift a deep well pump is needed 3 Impeller is plugged 3 Clean impeller see Maintenance 4 Check valve or foot valve is stuck 4 Replace check val...

Page 11: ...92PBBB C105 214PFA Impeller Screw C30 51SS 8 Diffuser C1 258PCA C1 258PCA 8A Diffuser C1 274P 9 Screw 8 32 RH U30 869SS U30 869SS U30 542SS 1 and 1 1 2 HP 4 Req d 2 HP 2 Req d Lockwasher U43 21SS 10 V Clamp C19 54SS C19 54SS C19 37A 11 Tank Body Front Half Incl No 12 C176 53PA C176 53PA 11A Tank Body Front Half Complete Incl Nos 3 and 12 C176 62PA 12 Draincock 1 4 NPT U212 68T U212 68T U212 68T 13...

Page 12: ... Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES OWNER S MANUAL Model No 390 2622 390 262553 390 2623 The model number of your Sprinkler Pump will be found on a plate attached to the side of the pump body When requesting...