INTRODUCTION

Please read our instructions before you install and use your
new pump; this will help you obtain full value and good ser-
vice from it. It will also help you avoid needless service costs
that result from causes we cannot control and cannot cover
in our warranty.

Carefully read and follow all safety instructions in this
manual or on pump.

This is a safety alert symbol.

When you see this symbol on your pump or in this manual,
look for one of the following signal words and be alert to the
potential for personal injury.

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

can 

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The word 

NOTICE 

indicates special instructions which are

important but not related to hazards.

1. Read these rules and instructions carefully. Failure to fol-

low them could lead to serious bodily injury and/or prop-
erty damage.

2. Check your local codes before installing. You must com-

ply with their rules.

3. Vent sewage or septic tank according to local codes.

4. Do not install pump in any location classified as haz-

ardous by National Electrical Code, ANSI/NFPA 70-1984.

Hazardous voltage. Can shock, burn

or cause death.

During operation the pump is in water.

To avoid fatal shocks, proceed as follows if pump needs
servicing:

5A. Disconnect power to outlet box before pulling pump

cord plug.

5B. Take extreme care when changing fuses. Do not stand

in water or put your finger in fuse socket.

5C. Do not modify cord and plug unless removing plug com-

pletely and wiring pump directly into switch box or con-
troller. When using cord and plug, plug into a grounded
outlet only. When wiring to a system control, connect
pump ground lead to system ground.

6.

Do not run pump dry. Dry running can overheat pump,
(causing burns to anyone handling it) and will void war-
ranty.

7. Pump normally runs hot. To avoid burns when servicing

pump, allow it to cool for 20 minutes after shutdown be-
fore handling it.

8. In normal service, motor should not need oiling. 

DO

NOT 

attempt to oil pump motor. A special oil has been

put into the motor housing at the factory; use of any
other oil will void warranty and could damage the pump.

FULL ONE YEAR WARRANTY ON  SEARS SUBMERSIBLE SUMP PUMPS

During the first year after the date of purchase, Sears will repair or replace this pump, free of charge, if defective in materials or
workmanship.

This warranty does not cover repairs on replacement parts necessary because of abuse or negligence including failure to in-
stall, adjust and operate this pump according to the instructions in the owner’s manual.

LIMITED WARRANTY ON CRAFTSMAN SUBMERSIBLE SUMP PUMPS

During the second year after the date of purchase, Sears will furnish, free of charge, a replacement part for any defective part.
You pay for labor.

LIMITATION OF LIABILITY

SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL LOSS
OR EXPENSE FROM PROPERTY DAMAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF THIS PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclu-
sion may not apply to you.

WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPART-
MENT IN THE UNITED STATES of AMERICA. For service outside the U.S.A., contact your local Sears Service Center or store.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Sears, Roebuck and Co., Dept. 817 WA, Hoffman Estates, IL 60179

GENERAL SAFETY INFORMATION

Summary of Contents for CRAFTSMAN 390.304050

Page 1: ...ting Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Service Repair...

Page 2: ...witch box or con troller When using cord and plug plug into a grounded outlet only When wiring to a system control connect pump ground lead to system ground 6 Do not run pump dry Dry running can overh...

Page 3: ...tighten only The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid To meet minimum flow requirements 2 feet per second in discharge line size pipe as follows A...

Page 4: ...so voids the warranty and could ruin the pump ELECTRICAL CONNECTIONS Risk of electric shock When servicing pump always disconnect power to electrical outlet and remove pump electric cord from outlet...

Page 5: ...s disconnect power to electrical outlet and remove pump electric cord from outlet 1 If pump does not operate a Check for loose plug at electric outlet b Check for blown fuses or tripped circuit breake...

Page 6: ...itch Replacement Figure 7 NOTICE Float must be able to swing through its complete arc without interference from sidewall of sump plumbing or any other object 1 Unplug cord from power source 2 Remove t...

Page 7: ...pper Volute 5 PS17 67 Cord Switch Assembly 6 CC0030 13 Clamp 7 U30 955SS 8 x 5 8 Type A Screw 8 U30 912PS Screw 4 required F642 9307 Owner s Manual Not Shown Quantity ONE unless otherwise noted 2 1 3...

Page 8: ...existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES Americ...

Reviews: