background image

SERVICE

6

Impeller Replacement (Figure 6)

1. Unplug cord from power source.

2. Disconnect discharge piping at the check valve and lift

pump out of sump.

Do not lift pump by power cord, use T-

handle on top of motor, or lift out of sump using
piping.

3. Remove screws from lower volute housing and separate

volute halves.

4. Hold shaft with screwdriver in slot in end of shaft; un-

screw impeller from shaft.

5. Thread new impeller onto shaft. Hold shaft with screw-

driver and tighten impeller firmly hand tight.

6. Remount lower volute housing.

7. Lower pump into sump by piping, then reattach dis-

charge piping to check valve sleeve. Plug in unit.

8. Pump is ready for operation. To avoid flooding, test pump

before operating by filling sump and running pump
through one complete cycle to be sure that switch works.

Switch Replacement (Figure 7)

NOTICE:

Float must be able to swing through its complete

arc without interference from sidewall of sump, plumbing
or any other object.

1. Unplug cord from power source.

2. Remove tether clamp screw and slide cord from clamp.

Unscrew T-handle to remove cord.

3. Insert new cord in tether clamp in same location on cord

with respect to float.

4. Tighten tether clamp screw. Connect T-handle to pump.

5. Check sump pump operation by filling sump with water

and observing operation through one complete cycle.

Failure to check installation with water

in sump can lead to improper operation, premature
pump failure and flooding.

783 0394

Screwdriver

slot

Lower
Volute
Housing

Upper
Volute
Housing

Impeller

Volute Screw
( 11 Places )

Turn impeller counter-clockwise
hand tight.

T-Handle

Disassembly

Reassembly

Notice: Submerge complete pump in a 
disinfectant solution ( chlorox or chlorine )
for at least one hour before disassembling
pump.

Figure 6

3-1/2"

Tether clamp

screw

Clamp

784 0394

Figure 7

Summary of Contents for CRAFTSMAN 390.304050

Page 1: ...ting Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Service Repair...

Page 2: ...witch box or con troller When using cord and plug plug into a grounded outlet only When wiring to a system control connect pump ground lead to system ground 6 Do not run pump dry Dry running can overh...

Page 3: ...tighten only The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid To meet minimum flow requirements 2 feet per second in discharge line size pipe as follows A...

Page 4: ...so voids the warranty and could ruin the pump ELECTRICAL CONNECTIONS Risk of electric shock When servicing pump always disconnect power to electrical outlet and remove pump electric cord from outlet...

Page 5: ...s disconnect power to electrical outlet and remove pump electric cord from outlet 1 If pump does not operate a Check for loose plug at electric outlet b Check for blown fuses or tripped circuit breake...

Page 6: ...itch Replacement Figure 7 NOTICE Float must be able to swing through its complete arc without interference from sidewall of sump plumbing or any other object 1 Unplug cord from power source 2 Remove t...

Page 7: ...pper Volute 5 PS17 67 Cord Switch Assembly 6 CC0030 13 Clamp 7 U30 955SS 8 x 5 8 Type A Screw 8 U30 912PS Screw 4 required F642 9307 Owner s Manual Not Shown Quantity ONE unless otherwise noted 2 1 3...

Page 8: ...existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES Americ...