background image

2

CONTENTS

INTRODUCTION/WARRANTY .........................................2

SAFETY ..............................................................................2

INSTALLATION...............................................................3-4

OPERATION ......................................................................4

MAINTENANCE ..............................................................4-5

PARTS ................................................................................5

INTRODUCTION

Please read our instructions before you install and use your
new pump; this will help you obtain full value and good ser-
vice from it. It will also help you avoid needless service costs
that result from causes we cannot control and cannot cover
in our warranty.

READ AND FOLLOW

SAFETY INSTRUCTIONS!

Carefully read and follow all safety instructions in
this manual or on pump.

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for per-
sonal injury!

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

will 

or 

can 

cause se-

rious personal injury, death or major property damage if 
ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The word 

NOTICE 

indicates special instructions which are

important but not related to hazards.

1. To avoid risk of serious bodily injury and property dam-

age, read safety instructions carefully before installing
pump.

2. Follow local and/or national plumbing and electrical

codes when installing pump.

Use this pump only on a 115 volt circuit.

Pump is equipped with an approved 
3-conductor cord and 3-prong, grounding-

type plug. To reduce the risk of electric shock, con-
nect it to a properly grounded, grounding-type
receptacle.

Do not operate the pump continuouisly at a discharge
pressure of more than 12 psi (83 kPa) or discharge lift of
more than 28’ (8.5 M), as the motor will exceed the nor-
mal safe operating temperature and may heat to 180° -
190° F (82° C - 88° C).

INSPECTION

This pump was thoroughly inspected, tested, and packaged
before shipment. Report any damage immediately to the
store where it was purchased.  

Hazardous
voltage

Discharge Height in Feet Above Pumping Level

Model

3

10

15

20

30

40

390.269152

5.5

5.0

4.6

4.0

2.5

1.0 

}

GPM

PERFORMANCE

ONE YEAR FULL WARRANTY

Provided that it is installed and operated according to the owner’s manual instructions, if this pump fails due to a
defect in material or workmanship within one year from the date of purchase, it will be replaced or repaired free
of charge.

Warranty service is available by returning this product to place of purchase for replacement, or by calling 
1-800-4-MY-HOME

®

to arrange for repair.

This warranty is VOID if this pump is used for commercial or rental purposes.

Sears is not liable for loss or damage to property, nor for any incidental or consequential loss or expense from
property  damage, that results directly or indirectly from the use of this product.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Sears Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179

Summary of Contents for CRAFTSMAN 390.269152

Page 1: ...his Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Operation Maintenace Repair Parts PRINTED IN U S A PORTABLE UTILITY PUMP Form No F642 05001 4 22 05 629 0405 IN OUT 512 0405 I N O U T Pump out a flooded basement Empty a clogged sink or tub ...

Page 2: ... with an approved 3 conductor cord and 3 prong grounding type plug To reduce the risk of electric shock con nect it to a properly grounded grounding type receptacle Do not operate the pump continuouisly at a discharge pressure of more than 12 psi 83 kPa or discharge lift of more than 28 8 5 M as the motor will exceed the nor mal safe operating temperature and may heat to 180 190 F 82 C 88 C INSPEC...

Page 3: ...Install a strainer or the Pud L Scoop tm to protect the pump from large solids NOTICE Attach the Pud L Scoop tm to the end of the inlet line and place it in at least 1 2 of water at the lowest point to be pumped Be sure all connections are air tight INLET HOSE GOES IN THE WATER OUTLET HOSE STAYS OUT OF THE WATER MOTOR MUST STAY DRY Make sure all inlet connections are tight no air leaks and the inl...

Page 4: ...uring normal operation Do not touch motor when it is operat ing or when it is hot Plug motor cord into 3 wire grounded 115 volt A C outlet 60 Hz Risk of fire or explosion if used to pump flammable liquids or if used in explosive atmo spheres Pump is designed to pump water at temperatures between 32 77 F 0 25 C only Pump water only with this pump MAINTENANCE INSTRUCTIONS Hazardous voltage Can shock...

Page 5: ...ittle lithium based grease to the inside bore of the metal insert To insert the impeller into the metal insert Press down on the impeller to bend a couple vanes on top to the left counter clockwise Slide the impeller into the metal insert Make sure the impeller is completely and evenly seated 5 1 2 3 Figure 2 Remove Face Plate Figure 5 Seal Removal Figure 6 Seal Installation Impeller Metal Insert ...

Page 6: ...he motor shaft 4 Insert the O Ring and cover plate Make certain that the O Ring remains seated in the groove 5 Secure the assembly with the two cover screws Tighten these evenly but do not over tighten the screws Typical uses for the Utility Pump Pump out a flooded basement Empty a clogged sink or tub 6 629 0405 IN OUT I N O U T Figure 8 Install Pump End Figure 9 Install Cover Plate ...

Page 7: ...n Head Screw 4 2 Front Wear Plate 1 C3 201SS 3 O Ring 1 U9 239 4 Impeller 1 RP0001077 5 Impeller Cavity Insert 1 U97 146 6 U Cup Seal 1 16FA019 4 7 Pump Body 1 C76 69P 8 Slinger 1 RP0001616 9 Motor 1 M0015 115 10 Brush Kit 1 PKG 201 Pud L Scoop 1 SA35 To Order Parts Call Sears Product Service 1 800 366 7278 Not illustrated Standard hardware item purchase locally ...

Page 8: ...essional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytime day or night U S ...

Reviews: