background image

INSTALLATION

OIL THE PUMP

Oil the pump with 1/2 tablespoon food grade mineral or veg-
etable oil with each use. Pour the oil in the ‘IN’ port. Three
1/2 tablespoon oil packets are included.

NOTICE: 

The pump depends on the liquid being pumped

for lubrication.

DO NOT RUN THE PUMP DRY! 

If the pump does not start to move water in 30 seconds or
less, recheck the installation and plumbing.

Mount the pump solidly on a stable platform.

USE 1/2” HOSE (or larger)

Use a reinforced hose on the inlet. The pump should be less
than 10’ above and less than 25’ to one side of the water
source. Make the outlet hose as short as possible - 25’ or less.

Check the washer in the inlet fitting to make sure it is air-
tight. If this joint leaks air, the pump will not operate.

KEEP THE HOSES AS 
STRAIGHT AS POSSIBLE

To reduce friction, do not coil or kink the hoses. When
pumping from a well or stream, raise the inlet hose a few
inches off the bottom to avoid sucking in sand, silt or peb-
bles (which can disable the impeller). Install a strainer or the
Pud-L-Scoop(tm) to protect the pump from large solids .

NOTICE: 

Attach the Pud-L-Scoop(tm) to the end of the inlet

line and place it in at least 1/2” of water at the lowest point
to be pumped. Be sure all connections are air tight. 

INLET HOSE GOES IN THE WATER; 
OUTLET HOSE STAYS OUT OF THE
WATER. MOTOR MUST STAY DRY 

Make sure all inlet connections are tight (no air leaks) and
the inlet hose is in the water. Make sure the end of the out-
let hose is not under water. If the outlet is under water, the
pump may not work. 

Plug the cord into a 3-wire, 115 volt, 60 Hz, grounded A.C.
outlet. 

You should get water in 30 seconds or less. If not, add more
oil and repeat the process. If your pump does not prime on
the second try, check the impeller and the inside of the
pump head for wear. Replace as needed.

3

IN

IN

Oil

4836 0205

Do Not Run Pump Dry!

STEP 1

No kinks!

No Coils!

Straight 

Hose!

4838 0205

STEP 3

IN

Water IN

Water OUT

Outlet Hose

Plug in pump to start it.

NOTE:

 If you don’t get water in 

30 seconds or less, add more oil 
and repeat the process.
See Step 1.

Inlet Hose

STEP 4

IN

OUT

1/2" or Larger 
Outlet Hose

4837A 0205

Water OUT

Water IN

1/2" or Larger
Reinforced 
Inlet Hose

STEP 2

Summary of Contents for CRAFTSMAN 390.269152

Page 1: ...his Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Operation Maintenace Repair Parts PRINTED IN U S A PORTABLE UTILITY PUMP Form No F642 05001 4 22 05 629 0405 IN OUT 512 0405 I N O U T Pump out a flooded basement Empty a clogged sink or tub ...

Page 2: ... with an approved 3 conductor cord and 3 prong grounding type plug To reduce the risk of electric shock con nect it to a properly grounded grounding type receptacle Do not operate the pump continuouisly at a discharge pressure of more than 12 psi 83 kPa or discharge lift of more than 28 8 5 M as the motor will exceed the nor mal safe operating temperature and may heat to 180 190 F 82 C 88 C INSPEC...

Page 3: ...Install a strainer or the Pud L Scoop tm to protect the pump from large solids NOTICE Attach the Pud L Scoop tm to the end of the inlet line and place it in at least 1 2 of water at the lowest point to be pumped Be sure all connections are air tight INLET HOSE GOES IN THE WATER OUTLET HOSE STAYS OUT OF THE WATER MOTOR MUST STAY DRY Make sure all inlet connections are tight no air leaks and the inl...

Page 4: ...uring normal operation Do not touch motor when it is operat ing or when it is hot Plug motor cord into 3 wire grounded 115 volt A C outlet 60 Hz Risk of fire or explosion if used to pump flammable liquids or if used in explosive atmo spheres Pump is designed to pump water at temperatures between 32 77 F 0 25 C only Pump water only with this pump MAINTENANCE INSTRUCTIONS Hazardous voltage Can shock...

Page 5: ...ittle lithium based grease to the inside bore of the metal insert To insert the impeller into the metal insert Press down on the impeller to bend a couple vanes on top to the left counter clockwise Slide the impeller into the metal insert Make sure the impeller is completely and evenly seated 5 1 2 3 Figure 2 Remove Face Plate Figure 5 Seal Removal Figure 6 Seal Installation Impeller Metal Insert ...

Page 6: ...he motor shaft 4 Insert the O Ring and cover plate Make certain that the O Ring remains seated in the groove 5 Secure the assembly with the two cover screws Tighten these evenly but do not over tighten the screws Typical uses for the Utility Pump Pump out a flooded basement Empty a clogged sink or tub 6 629 0405 IN OUT I N O U T Figure 8 Install Pump End Figure 9 Install Cover Plate ...

Page 7: ...n Head Screw 4 2 Front Wear Plate 1 C3 201SS 3 O Ring 1 U9 239 4 Impeller 1 RP0001077 5 Impeller Cavity Insert 1 U97 146 6 U Cup Seal 1 16FA019 4 7 Pump Body 1 C76 69P 8 Slinger 1 RP0001616 9 Motor 1 M0015 115 10 Brush Kit 1 PKG 201 Pud L Scoop 1 SA35 To Order Parts Call Sears Product Service 1 800 366 7278 Not illustrated Standard hardware item purchase locally ...

Page 8: ...essional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytime day or night U S ...

Reviews: