background image

MAINTENANCE

8. Hold the motor shaft with pliers or vice grips

through the opening in the pump adapter. Unscrew
the impeller nut off the end of the shaft (see Figure
20).

9. The impellers are keyed to the shaft and do not un-

screw. Insert two screw drivers on opposite sides
under the exposed impeller and pry the impeller
off (Figure 21) to remove it.

10. Carefully tap a small screwdriver or thin bladed

chisel in between the intermediate volute and the
pump adapter in two or three places around the
pump to separate the castings (Figure 22).

Do not

mar the sealing surfaces; do not break pieces out
of the adapter or volute – the castings are easily
damaged.

11. Remove the intermediate volute and slide the im-

peller spacer off of the shaft.

12. Remove the impeller. Don’t disturb the shaft keys if

you are only replacing the seal.

13. Rotate the seal spring retainer cup so that the slot

lines up with the shaft keys; remove the cup and
spring.

14. Remove the two cap screws holding the adapter

bracket to the motor.

15. With two screwdrivers on opposite sides of the

pump, carefully pry the pump adapter away from
the motor. This will pull the seal off of the motor
shaft. 

Use caution to make sure that the ceramic

seal does not dig into the shaft and scratch the
shaft’s sealing surface.

Installation Of New Seal

1. Clean all gasket surfaces thoroughly before re-

assembly. Clean the seal bore cavity in the pump
adapter.

2. Wet the rubber seat ring with soapy water and push

the stationary part of the seal into the seal bore cav-
ity. Use a piece of 1” pipe pressing on a cardboard
washer (to prevent damaging seal surface) as a
press. 

Make sure that the seal half is fully seated

in the seal bore cavity.

Remove the cardboard once

the seal is in place.

3. Make sure that the shaft keys are in place on the

shaft. If they are not, squeeze them in place now
with slip joint pliers. 

Do not tap them or hit them

with a hammer; you could bend the shaft

(see

Figure 23). When the keys are correctly installed, the
adapter will pass over the keys without interference.

13

Figure 20

Figure 21

Figure 22

Use pliers –

with care –

no hammers.

Figure 23

Summary of Contents for CRAFTSMAN 390.253251

Page 1: ...ing Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Operation Mainte...

Page 2: ...or below at all times Over pressure can cause tank blowup in stall relief valve capable of passing full pump vol ume at 100 PSI 5 With a new well test well for purity before use Consult local Health...

Page 3: ...in the tank drops to 40 pounds per square inch PSI and stops the pump when the tank pressure reaches 60 PSI Adapter Flange The VMS pump is equipped with an adapter flange This adapter facilitates inst...

Page 4: ...3 2 2 1 1 HP 29902 60 11 0 9 5 8 6 7 8 6 6 5 4 4 7 4 6 4 2 3 4 2 6 1 7 40 11 7 11 1 10 2 9 2 7 8 6 4 5 1 5 0 4 5 4 0 3 2 2 1 29660 60 11 0 9 5 8 6 7 8 6 6 5 4 4 7 4 6 4 2 3 4 2 6 1 7 Multi Stage Pump...

Page 5: ...ough pump 8 Unions installed near pump and well will aid in ser vicing Leave room to use wrenches Motor normally operates at high temper ature and will be too hot to touch It is protected from heat da...

Page 6: ...always at least five feet from the bottom of the well 8 Tighten all hose clamps securely on plastic pipe Use two clamps per joint to prevent air leaks into suction pipe Clamp screws should be on oppos...

Page 7: ...e b Leather packer type ejector with built in foot valve c Turned couplings supplied with packer type ejector d Well casing adapter supplied with packer type ejector 1 Connect ejector to first length...

Page 8: ...mponents When water is drawn off through house fixtures the pressure in the tank is lowered and the pressure switch starts the pump Standard Tank Connection When a standard tank is used an air volume...

Page 9: ...ange voltage A B L2 L1 A B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connector Type Move black wire from A to L1 1 1 2 2 3 3 3187 0398 A B L2 L1 A B L2 L1 Ground Screw Move white...

Page 10: ...igure 14 Page 9 Priming The Pump Burn hazard NEVER run pump dry Running pump without water may cause pump to overheat damaging seal and possibly causing burns to persons handling pump Fill pump with w...

Page 11: ...tem by alternately opening and closing faucets in the system With faucets open pressure will drop until pump starts with faucets closed pressure will build up until pump shuts off 7 There are conditio...

Page 12: ...cording the gauge you may have air leaks in the suction line or a clogged impeller Cleaning the Deep Well Jet 1 Disconnect power 2 Disconnect piping and well seal or casing adapter 3 Withdraw jet asse...

Page 13: ...screws holding the adapter bracket to the motor 15 With two screwdrivers on opposite sides of the pump carefully pry the pump adapter away from the motor This will pull the seal off of the motor shaf...

Page 14: ...the long cap screws to check this alignment It cannot be stressed too strongly that all bolt holes and water passages of all gaskets and volutes MUST line up with each other or the pump will not be as...

Page 15: ...iring 5 Clean by sliding piece of plain paper between contacts 6 Make sure motor voltage exactly matches power supply voltage 1 Refer to instructions on wiring 2 Check with power company Install heavi...

Page 16: ...TS 16 20 100 80 60 40 9 10 1 3 4 5 6 7 8 2 11 17 16 15 14A 14A 14B 14B 14C 13 14 18 1281 0994 12 12 2080 1095 1 1B 1A 2A 2B 2C 2D 5 4 6 2E 2F 2 3 7 8 9 10 20 100 80 60 40 Pressure Regulator Multi Stag...

Page 17: ...eq Key Part No Number Part Description 1 J112 14 Pressure Regulator Body w Seat 1A U111 212T Barbed Fitting Elbow 1B J66 16 Valve Seat 2 J220 16B Diaphragm Assembly 2A J42 5 Regulator Guide 2B J62 9 S...

Page 18: ...30 277ZP 3 8 16x2 1 2 Hex Hd Bolt 3 Req 7 J21 17 J21 21 Seal Ring Lower 8 J16 20ZZP J16 24ZZP Lower Flange 9 U36 38ZP U36 38ZP 3 8 Hex Nut 3 Req Key Part No Number Part Description 1 J20 12 Adapter Ga...

Page 19: ...rainer 12 U11 104P Plastic Pipe Adapter J216 13 J216 14 Casing Adapter U37 116GP U37 116GP 1 x 6 T O E Nipple Max Depth with Jet Package No 29670 29902 29660 Pump Venturi 2 Single 3 Single 4 Double Mo...

Page 20: ...or to inquire about an existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists...

Reviews: