background image

MAINTENANCE

Using the Compound Gauge

If the pump or system seems to be operating ineffi-
ciently, the compound gauge can sometimes help de-
termine the problem.
A compound gauge is a combination vacuum and pres-
sure gauge which will indicate (1) receding water level
in the well, (2) leakage in the suction line or in the
pump, or (3) clogged impeller.
To use, install the gauge in the air volume control (AVC)
port in the base of the pump. Open all shutoff valves
between pump and household piping. Tighten regula-
tor screw as far as possible. After running pump a few
minutes to eliminate all air from pipes, loosen regula-
tor screw until compound gauge shows 15” of vacuum.
This setting indicates that the pressure regulator is set
for delivery of the highest volume of water possible.
Let the pump run a few minutes; if the water level in
the well is falling, the vacuum  will increase. If neces-
sary, reduce the regulator setting to bring the vacuum
reading back to 15”. If the pump does not develop 15”
of vacuum according the gauge, you may have air leaks
in the suction line or a clogged impeller.

Cleaning the Deep Well Jet

1. Disconnect power.
2. Disconnect piping and well seal or casing adapter.
3. Withdraw jet assembly from the well.
4. Unscrew and remove the venturi. Remove the noz-

zle  with a socket wrench and clean.

5. Replace all parts, reprime, and turn on power.

Pump Diassembly

1.  Pull disconnect switch. Disconnect power lines

from pressure switch.

2. Remove the two cap screws holding the pump to

the flange adapter. Don’t disturb the piping in the
well.

3. Remove the flange adapter gasket and scrape the

surfaces clean.

4. Leaving the tubing in place, unscrew and remove

the straight barbed fitting at the pressure switch.

5. Draw a line down the side of the pump with a

marker to help alignment during reassembly. Mark
the pump from the motor to the base volute (see
Figure 18).

6. Turn  the pump upside down on the bench and

block it. Remove the four cap screws from the base.
With a mallet, tap upward on the base to loosen it.
Lift the base off of the intermediate volute (see
Figure 19). 

7. To reduce the chance of dropping the pump onto

your foot, lay it down on the bench; block it so it
won’t roll.

12

Figure 18

Figure 19

Summary of Contents for CRAFTSMAN 390.253251

Page 1: ...ing Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Operation Mainte...

Page 2: ...or below at all times Over pressure can cause tank blowup in stall relief valve capable of passing full pump vol ume at 100 PSI 5 With a new well test well for purity before use Consult local Health...

Page 3: ...in the tank drops to 40 pounds per square inch PSI and stops the pump when the tank pressure reaches 60 PSI Adapter Flange The VMS pump is equipped with an adapter flange This adapter facilitates inst...

Page 4: ...3 2 2 1 1 HP 29902 60 11 0 9 5 8 6 7 8 6 6 5 4 4 7 4 6 4 2 3 4 2 6 1 7 40 11 7 11 1 10 2 9 2 7 8 6 4 5 1 5 0 4 5 4 0 3 2 2 1 29660 60 11 0 9 5 8 6 7 8 6 6 5 4 4 7 4 6 4 2 3 4 2 6 1 7 Multi Stage Pump...

Page 5: ...ough pump 8 Unions installed near pump and well will aid in ser vicing Leave room to use wrenches Motor normally operates at high temper ature and will be too hot to touch It is protected from heat da...

Page 6: ...always at least five feet from the bottom of the well 8 Tighten all hose clamps securely on plastic pipe Use two clamps per joint to prevent air leaks into suction pipe Clamp screws should be on oppos...

Page 7: ...e b Leather packer type ejector with built in foot valve c Turned couplings supplied with packer type ejector d Well casing adapter supplied with packer type ejector 1 Connect ejector to first length...

Page 8: ...mponents When water is drawn off through house fixtures the pressure in the tank is lowered and the pressure switch starts the pump Standard Tank Connection When a standard tank is used an air volume...

Page 9: ...ange voltage A B L2 L1 A B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connector Type Move black wire from A to L1 1 1 2 2 3 3 3187 0398 A B L2 L1 A B L2 L1 Ground Screw Move white...

Page 10: ...igure 14 Page 9 Priming The Pump Burn hazard NEVER run pump dry Running pump without water may cause pump to overheat damaging seal and possibly causing burns to persons handling pump Fill pump with w...

Page 11: ...tem by alternately opening and closing faucets in the system With faucets open pressure will drop until pump starts with faucets closed pressure will build up until pump shuts off 7 There are conditio...

Page 12: ...cording the gauge you may have air leaks in the suction line or a clogged impeller Cleaning the Deep Well Jet 1 Disconnect power 2 Disconnect piping and well seal or casing adapter 3 Withdraw jet asse...

Page 13: ...screws holding the adapter bracket to the motor 15 With two screwdrivers on opposite sides of the pump carefully pry the pump adapter away from the motor This will pull the seal off of the motor shaf...

Page 14: ...the long cap screws to check this alignment It cannot be stressed too strongly that all bolt holes and water passages of all gaskets and volutes MUST line up with each other or the pump will not be as...

Page 15: ...iring 5 Clean by sliding piece of plain paper between contacts 6 Make sure motor voltage exactly matches power supply voltage 1 Refer to instructions on wiring 2 Check with power company Install heavi...

Page 16: ...TS 16 20 100 80 60 40 9 10 1 3 4 5 6 7 8 2 11 17 16 15 14A 14A 14B 14B 14C 13 14 18 1281 0994 12 12 2080 1095 1 1B 1A 2A 2B 2C 2D 5 4 6 2E 2F 2 3 7 8 9 10 20 100 80 60 40 Pressure Regulator Multi Stag...

Page 17: ...eq Key Part No Number Part Description 1 J112 14 Pressure Regulator Body w Seat 1A U111 212T Barbed Fitting Elbow 1B J66 16 Valve Seat 2 J220 16B Diaphragm Assembly 2A J42 5 Regulator Guide 2B J62 9 S...

Page 18: ...30 277ZP 3 8 16x2 1 2 Hex Hd Bolt 3 Req 7 J21 17 J21 21 Seal Ring Lower 8 J16 20ZZP J16 24ZZP Lower Flange 9 U36 38ZP U36 38ZP 3 8 Hex Nut 3 Req Key Part No Number Part Description 1 J20 12 Adapter Ga...

Page 19: ...rainer 12 U11 104P Plastic Pipe Adapter J216 13 J216 14 Casing Adapter U37 116GP U37 116GP 1 x 6 T O E Nipple Max Depth with Jet Package No 29670 29902 29660 Pump Venturi 2 Single 3 Single 4 Double Mo...

Page 20: ...or to inquire about an existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists...

Reviews: