INTRODUCTION

Please read our instructions before installing and using
your Deep Well Jet Pump. This will help you obtain the
full benefits of the quality and convenience built into
this equipment. It will also help you avoid any needless
service expense resulting from causes beyond our con-
trol which are not covered by our warranty.

Carefully read and follow all safety instructions in this
manual or on pump

This is the safety alert symbol. When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury!

Warns about hazards that 

will 

cause seri-

ous personal injury, death or major property damage if
ignored.

Warns about hazards that 

will 

or 

can

cause serious personal injury, death or major property
damage if ignored.

Warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.
The word 

NOTICE 

indicates special instructions

which are important but not related to hazards.

1. To avoid risk of serious bodily injury and property

damage, read safety instructions carefully before in-
stalling pump.

2. Follow local and/or national plumbing and electri-

cal codes when installing pump.

3. Keep well covered while installing pump to prevent

leaves and other debris from falling into well, con-
taminating well and possibly damaging pump.

4. Protect pump and piping system from freezing.

Allowing pump or water system to freeze could
severely damage pump and voids warranty.

To  avoid serious injury and equip-

ment damage, limit system pressure to 100
pounds per square inch (PSI) or below at all
times. Over-pressure can cause tank blowup; in-
stall relief valve capable of passing full pump vol-
ume at 100 PSI.

5. With a new well, test well for purity before use.

Consult local Health Department for procedure.

Hazardous voltage. Can shock, burn,

cause death, or start fires.

6. Disconnect electrical power source before in-

stalling or working on pump.

7. Ground pump with a ground wire run from ground-

ing lug on motor to a grounded lead in the service
panel.

8. Line voltage and frequency of electrical power sup-

ply must agree with motor nameplate.

9. Use of fuses or wire smaller than size recommended

in owner’s manual can cause overheating, possible
fires, and will void warranty.

10. This pump is a deep well jet pump. It is not de-

signed or intended for shallow well use. Use in a
deep well (more than 25’ depth to water).

FULL ONE YEAR WARRANTY ON CRAFTSMAN

®

WELL PUMP

For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective in material or
workmanship.

This warranty does not cover repairs or replacement parts necessary because of abuse or negligence including failure to
install, adjust and operate this pump according to the instructions in the owner’s manual.

LIMITATION OF  LIABILITY

SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL LOSS
OR EXPENSE FROM PROPERTY DAMAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or 
exclusion may not apply to you.
WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT
IN THE UNITED STATES.
This warranty applies only while the product is in use in the United States.
This warranty gives you specific legal rights, and you may also have other rights which vary from  state to state.

Sears, Roebuck and Co., Dept. 817 WA, Hoffman Estates, IL 60179

RULES FOR SAFE INSTALLATION AND OPERATION

Summary of Contents for CRAFTSMAN 390.2532

Page 1: ...ting Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Operation Maint...

Page 2: ...or below at all times Over pressure can cause tank blowup in stall relief valve capable of passing full pump vol ume at 100 PSI 5 With a new well test well for purity before use Consult local Health D...

Page 3: ...in the tank drops to 40 pounds per square inch PSI and stops the pump when the tank pressure reaches 60 PSI Adapter Flange The VMS pump is equipped with an adapter flange This adapter facilitates inst...

Page 4: ...e Jet Package No 29902 3 Single Pipe use 1 1 4 galvanized pipe Jet Package No 29660 4 Double Pipe Must be ordered through Sears Product Service 1 800 366 7278 1096 0697 Pump Body From Well Dirt and Sc...

Page 5: ...lastic pipe is ideal for double pipe installations Due to its light weight it is easy to handle and does not usually require a block and tackle for installation and removal Double Pipe Installation Pl...

Page 6: ...ter flange making sure that holes line up 13 Align locating lugs on pump base with locating lugs on adapter flange attach pump to flange with cap screws provided 14 See Discharge Pipe Sizes for inform...

Page 7: ...er installation 5 With ejector set install well casing adapter Remove pipe holder Align locating lugs and tighten adapter to form seal with well casing Discharge Pipe Sizes 1 If increasing discharge p...

Page 8: ...a single voltage motor NOTICE Never wire a 115 volt motor to a 230 volt line Remove Motor End Cover You will need to remove the motor end cover to change the voltage setting The illustration above al...

Page 9: ...be a solid copper wire at least as large as the power supply wires 2 There must be a solid metal connection between the pressure switch and the motor for motor grounding protection If the pressure swi...

Page 10: ...apidly to 50 pounds per square inch or more as ejector and pump prime If so go to step 4 below If pressure does not build to 50 PSI repeat steps a b and c under Step No 1 two or three times to re move...

Page 11: ...pump with regulator valve open HELPFUL HINTS MAINTENANCE How To Handle A Gaseous Well In some areas well water contains gases which must be allowed to escape before the water is used To deliver gas f...

Page 12: ...cording the gauge you may have air leaks in the suction line or a clogged impeller Cleaning the Deep Well Jet 1 Disconnect power 2 Disconnect piping and well seal or casing adapter 3 Withdraw jet asse...

Page 13: ...screws holding the adapter bracket to the motor 15 With two screwdrivers on opposite sides of the pump carefully pry the pump adapter away from the motor This will pull the seal off of the motor shaf...

Page 14: ...the long cap screws to check this alignment It cannot be stressed too strongly that all bolt holes and water passages of all gaskets and volutes MUST line up with each other or the pump will not be as...

Page 15: ...iring 5 Clean by sliding piece of plain paper between contacts 6 Make sure motor voltage exactly matches power supply voltage 1 Refer to instructions on wiring 2 Check with power company Install heavi...

Page 16: ...2 Req 14B J23 10 Wear Ring 2 Req 14C J23 11 Wear Ring 15 U36 175D Impeller Nut 16 J101 33 Base Volute w Wear Ring 17 U78 57CT Pipe Plug 1 4 NPT 18 Capscrew 3 8 16x4 1 4 Lg 4 Req Repair Parts List Mult...

Page 17: ...3 Spring 6 J61 5 Spring Guide 7 J52 9 Bonnet 8 Capscrew 5 16 18x3 4 Lg 4 Req 9 U30 69FTZP Adjusting Screw 5 16 18x2 10 U36 205ZP Locknut 5 16 18 Repair Parts List Pressure Regulator Standard hardware...

Page 18: ...7ZP U30 277ZP 3 8 16x2 1 2 Hex Hd Bolt 3 Req 7 J21 17 J21 21 Seal Ring Lower 8 J16 20ZZP J16 24ZZP Lower Flange 9 U36 38ZP U36 38ZP 3 8 Hex Nut 3 Req Key Part No Number Part Description 1 J20 12 Adapt...

Page 19: ...trainer 12 U11 104P Plastic Pipe Adapter J216 13 J216 14 Casing Adapter U37 116GP U37 116GP 1 x 6 T O E Nipple Max Depth with Jet Package No 2967 29902 29660 Pump Venturi 2 Single 3 Single 4 Double Mo...

Page 20: ...or to inquire about an existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialist...

Reviews: