D. REMOVING MAGNETRON
(Figures 11 Through 13)
(1) Remove the vent grille.
(2) Remove the mount, all.
(3) Remove the outer case.
(4) Disconnect the wireleads.
(5) Remove the three screws and
Magnetron
very
carefully.
NOTES:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or damage
may occur.
• When replacing the magnetron, be sure to install
the magnetron gasket in the correct position and be
sure that the gasket is in good condition.
• After replacing the magnetron, check for
microwave energy leakage with a survey meter.
The microwave energy leakage must be below the
limit of 5 mW/cm
2
. (All service adjustments should be
made for minimum microwave energy leakage
readings.)
7-8
Figure 11
Figure 13
Figure 12
Outcase
Vent Grille