STEP 3:
PREPARE THE VENTING BLOWER
WALL VENTED INSTALLATION:
1. Remove blower unit mounting screw(s) and blower
plate screw(s). Remove the blower plate from cabinet.
See
Figure 12.
2. Carefully lift the blower unit out of the microwave
oven. Disconnect the blower wire from connector.
See
Figure 13.
3. Use side cutters or tin snips to cut and remove
knockouts "B" from Back plate. Discard knockouts.
Be careful not to distort the plate. See
Figure 14.
4. Rotate the unit so that the exhaust ports face the rear
of the cabinet. See Figure 15. Before you insert
blower unit, blower wire must be like
Figure 15.
5. Reassemble the blower wire into the connector.
6. Place blower unit back into cabinet. Check that the
exhaust ports face towards the rear of the cabinet.
See
Figure 16.
7. Reattach the blower plate to the top of the cabinet as
it was originally assembled. Attach with blower unit
mounting screw(s) and then blower plate mounting
screw(s). See
Figure 17.
8. Go to STEP
4, PREPARE THE WALL AND UPPER
CABINET FOR INSTALLATION
located on page 13.
Parts "B"
Knockouts Parts "B"
blower plate
mounting screw(s)
(option)
blower plate
blower unit
mounting screw(s)
(option)
blower unit
Knockouts "B"
back plate
exhaust
ports
blower plate
mounting
screw(s) (option)
blower unit
mounting screw(s) (option)
blower unit
exhaust ports
blower wire
connector
exhaust
ports
blower
unit
Figure 12
Figure 13
Figure 14
Figure 16
Figure 17
Figure 15
Summary of Contents for 721.80513
Page 19: ...19 MEMO...
Page 20: ...Printed in Korea...