MAInTEnAnCE, REPAIR and TROuBLE SHOOTInG

Problem

Probable Cause

Try...

Blank display:

WMP101

Blank display:

WMP104

Reading “-EP-”

Flow but no flow rate reading

No power to unit

Batteries dead or misinstalled

Empty or partly filled pipe

Excessive air pockets or foaming

Heavily coated electrodes

Check power supply

Check wiring

Check polarity, replace batteries

Rearrange piping to ensure full pipe

Remove meter and wipe electrodes

MAInTEnAnCE AnD REPAIR

There are no user-serviceable parts in the WMP-Series me-

ters except the batteries in the WMP104.

Battery  Replacement. 

When  the  “low  bat”  indicator  ap-

pears,  the  batteries  should  be  changed.  Either  six  each 

AA alkaline cells are required, or two each C lithium cells 

with integrated wiring harness, depending on power option 

ordered with meter. To change the batteries, first remove 

the four screws which hold the top cover in place. Be care-

ful not to lose the washers. Move the top cover to one side 

and remove the foam retainer which covers the battery tray 

or pack.

> For units with AA alkaline batteries, remove the old bat-

teries from the battery tray, and replace them with fresh 

ones,  taking  care  to  follow  the  polarity  indicators  in  the 

battery tray.

> For units with C lithium batteries, carefully unplug each 

of the two battery wiring harness connectors. Slip the bat-

teries out from under the elastic retainer, and replace them 

with the new batteries. Reconnect each of the two wiring 

harness  connectors.  The  connectors  are  indexed  for  cor-

rect installation. 

Replace the foam retainer, then put the top cover back in 

place. Warning! Use Extreme Caution not to trap wiring or 

other  assembly  parts  under  the  housing  seal  -  this  may 

cause  an  ingress  of  water,  voiding  the  product  warranty. 

Put the four screws with washers back and tighten them 

firmly.  Environmental  and  Safety  note  -  take  care  to  dis-

pose of all batteries in accordance with Federal, State, and 

Local regulations.

TROuBLE SHOOTInG

6

Summary of Contents for WMP-Series

Page 1: ...WMP Series PLASTIC BODIED MAGMETER instructions W M P S eries P L A S T I C B O D I E D M A G M E T E R i n str u ctio n s 2 inch 1 inch ...

Page 2: ...Flow rate and total can be displayed in a variety of units customer selected and factory set The WMP Series is used for tracking flow rate and total flow in usage monitoring applications for instance in compliance with regulatory requirements These would include wells industrial wastewater heap leach mining discharge cooling tower deduct metering turf and landscape applications and other water rec...

Page 3: ...unregulated power supply 18 Vdc may damage the meter due to AC line input voltage fluctuation 6 each AA alkaline cells replaceable Estimated life is 1 year with meter in typical use or 3 years dry 2 each C lithium batteries replaceable Estimated life is 3 years with meter in typical use or 10 years dry Current sinking pulse opto isolated 24 Vdc at 10 mA max 1 gal pulse out or 1 liter pulse out dep...

Page 4: ...eametrics Follow the diagram below to make the connections Position This is an all position meter which can be installed either vertically or horizontally register up down or angled However entrained air or solids may make some positions preferable to others See the position diagram for guidance Less Ideal Air bubbles and sediment on the electrodes can affect accuracy Intermittent air bubbles pass...

Page 5: ...deal Air can be trapped Not Ideal Post valve cavitation can create air pocket Recommended Allows air to bleed off Recommended Keep pipe full at meter for accuracy Recommended Keeps pipe full at meter for accuracy WMP WMP WMP WMP WMP WMP 1X 5X 5X Expanded Pipe Swirling Flow Partially Open Butterfly Valve 1X WMP WMP Reduced Pipe 4 ...

Page 6: ...the display Then connect the pulse output Operation Grounding WMP101 For best performance especially in chemically noisy environments the gray ground wire and the bare drain wire should be connected together and to a good earth ground as close to the meter as possible Metal pipe and fittings in contact with the fluid should also be bonded to the same earth ground with corrosion resis tant connecti...

Page 7: ... in place Be care ful not to lose the wash ers Move the top cover to one side and remove the foam retainer which covers the battery tray or pack For units with AA alkaline batteries remove the old bat teries from the battery tray and replace them with fresh ones taking care to fol low the polarity indicators in the battery tray For units with C lithium batteries carefully unplug each of the two ba...

Page 8: ...LT 65200337 B 4 12 10 Seametrics Incorporated 19026 72nd Avenue South Kent Washington 98032 USA P 253 872 0284 F 253 872 0285 1 800 975 8153 www seametrics com ...

Reviews: