AG3000 INSTRUCTIONS
Seametrics • 253.872.0284
Page 21 seametrics.com
OPERATION
The AG3000 has a passcode system for restricting access
to the menus. The AG3000 comes from the factory with the
passcode set to 000000. When a user attempts to enter the
menu system (see details on page 19), the passcode entry
screen will be displayed.
The default passcode is 000000. If a different passcode has
previously been set, then the user must enter that passcode
at this time. After entering the passcode, or leaving it at
000000 if using the default passcode, the user does the tap
and hold sequence to move into the menu system.
To change the passcode
, you must use the
THIRD MENU
screen
. Access the
THIRD MENU screen
as follows:
• Enter the main menu system, as described above.
• On the main menu, tab over to the EXIT tab and
tap the up arrow five times. A
SUBMENU screen will
display.
• On the SUBMENU screen tab over to the EXIT tab
and tap
five times. The THIRD MENU screen will
display.
000000
ENTER PASSCODE
PRESS AND TO CHANGE
1.2345678
100
TOTAL
CU FT
X1000
RATE
GPM
T UNIT
R UNIT SET P DAMP
SET 4 SET 20 SET F
EXIT
TOTAL = GALLONS
PRESS + TO SET TOTAL
UNITS FOR DISPLAY
T UNIT R UNIT SET P DAMP
SET 4 SET 20 SET F
EXIT
TOTAL:
PRESS TO CHANGE
GALLONS
FWD TOTAL
SETCD
PRESS + TO SET
SAMP
FOUT
EXIT
000000
PASSCODE
SETD
PLMIN
TEST
To Change a Passcode and Decimal Places
•
To set the PASSCODE, hold and tap and then use the
and to enter the new code.
• Hold and tap again to return to the THIRD MENU
screen.
• Tab to EXIT, and then hold and tap to return to the
SUBMENU.
To change the number of decimal places in the total
• To set the decimal point, hold and tap on SETD and
then use the to move the decimal point.
• Hold and tap again to return to the THIRD MENU
screen.
• Tab to EXIT, and then hold and tap to return to the
SUBMENU.
PLMIN
PLMIN shows the minimum degree of stability required
to activate the DAMP filter. 10 would indicate that meter
readings that jump more than +/- 90% would not be
filtered. Zero indicates that the filters will always be
applied.
TEST
TEST allows the user to initiate a fully functional, artificial
flow rate for the purpose of testing other connected
equipment. When TEST is applied, all features of the
meter will function at the stated flow rate (in gallons per
second).
For TEST to function, the meter must be filled (not EMPTY
PIPE).
To enter a value into the TEST feature, navigate to the
TEST tab and enter a flow rate value in the VAL screen (in
gallons per second only,) then
to the VAL box and
to the ON screen. This will initiate the TEST feature. The
next would bring you to the OFF screen, but you can
‘hold and tap’ the arrows to return you to the sub menu
while the feature operates.
After use, the TEST feature must be turned OFF.
If the
TEST feature is not turned OFF, the stated static flow rate
(in gallons per second) will be shown any time the meter
is full or in a flowing condition. Flow values recorded
by the meter while the TEST feature is operating are
permanently recorded in the displayed TOTAL. It may
be useful to note that these values are only written to
permanent memory every 15 minutes and cycling all
power within this 15 minute time frame will return the
meter to its previous total.
INFO
COMM MBID
FL DIR
SAMP
HPOLL
FOUT
EXIT
PRESS + TO VIEW INFO
ABOUT METER