CRACK PRO® MASTIC MACHINE
OPERATING INSTRUCTIONS
AUTOMATIC SAFETY INTERLOCKS
There are automatic safety interlocks that control the digital
controllers for material and heat transfer temperatures. The
agitator will not work until the material has reached a pre-
programmed temperature on the respective digital controllers.
Once the material controller reaches the programmed
temperature settings the white interlock light comes on, then the
agitator will automatically start turning when engaged. Opening
the lid turns off the agitator.
When adding material, open the lid and place a single block on it
and push it closed. Do not add more than 4 boxes of material at a
time.
See the temperature control page for instructions on how to set the controllers.