LED SENSOR (LED DIAGNOSTICS)
The voltage and current for each of the LEDs are monitored by the LED Sensor. If any LED fails, then
all LEDs must be turned off. A faulty PEL is more dangerous than no PEL at all. When an LED failure is
detected there is one* option that can be setup:
•
Trigger alarm relay
(Default: On)
*Turning off all LEDs upon failure is permanently enabled.
The PEL will re-run the LED diagnostics when it detects a day to night transition, or a night to day
transition. This will mean that if the LED failure is only temporary then the PEL will resume normal
operations the next day/night.
NOTE
: A custom configuration may not have all LEDs populated. If a factory reset is performed, LEDs
not being used will need to be switched to Zero intensity. This is discussed further in the Advanced Tab
section.
Disabling/Enabling Alarm Options
To
disable
the alarm relay, ensure the box to the left of the option is unchecked and click ‘Write.’
Options disabled